logo
  • About Us
    • Retail Customer Login
    • Business User Login
    • Retail Customer Registration
    • Business User Registration
  • 0
  • Shop Products
    • Ambulatory Equipment
    • Apparel
    • Appliances (Durable Goods)
    • Body Pressure Relief and Positioning
    • Clinical Laboratory
    • Diagnostic Instruments and Supplies
    • Drainage and Suction
    • Furnishings
    • Gloves
    • Housekeeping
    • Implants
    • Incontinence
    • Indicators and Signage
    • Instruments
    • IV Therapy
    • Needles and Syringes
    • Nurse's Station and Office Supplies
    • Nutritionals and Feeding Supplies
    • Orthopedic
    • Ostomy
    • other
    • Personal Hygiene
    • Pharmaceuticals
    • Physical Therapy
    • Respiratory
    • Services
    • Sterilization
    • Textiles
    • Training and Education
    • Urological
    • Utensils
    • Ventilators
    • Wound Care
    • Wound Closure
logo
  • 0
  • Retail Customer Login
  • Business User Login
  • Retail Customer Registration
  • Business User Registration
Shop Products
  • Ambulatory Equipment
  • Apparel
  • Appliances (Durable Goods)
  • Body Pressure Relief and Positioning
  • Clinical Laboratory
  • Diagnostic Instruments and Supplies
  • Drainage and Suction
  • Furnishings
  • Gloves
  • Housekeeping
  • Implants
  • Incontinence
  • Indicators and Signage
  • Instruments
  • IV Therapy
  • Needles and Syringes
  • Nurse's Station and Office Supplies
  • Nutritionals and Feeding Supplies
  • Orthopedic
  • Ostomy
  • other
  • Personal Hygiene
  • Pharmaceuticals
  • Physical Therapy
  • Respiratory
  • Services
  • Sterilization
  • Textiles
  • Training and Education
  • Urological
  • Utensils
  • Ventilators
  • Wound Care
  • Wound Closure
$

Rtx-502.2 cap GC Column 60m. Rtx-502.2 cap GC Column, Length: 60m, ID: 0.53mm, df: 3.00um, Excellent separation of trihalomethanes; ideal polarity for light hydrocarbons and aromatics, Application-specific columns with unique selectivity for volatile organic pollutants, Stable to 270 deg C

Rtx-225 cap GC Column 15m. Rtx-225 cap GC Column, Length: 15m, ID: 0.25mm, df: 0.25um, Excellent separation of trihalomethanes; ideal polarity for light hydrocarbons and aromatics, Application-specific columns with unique selectivity for volatile organic pollutants, Stable to 270 deg C

MXT-Volatiles Capillary Column 2um. MXT-Volatiles Capillary Column, Length: 105m, 0.53mm ID, Df: 2.00um, 4 1/2inID coil banded with copper wire

Rt-Q-BOND Column 10um. Rt-Q-BOND Column, Length: 30m, 0.25mm ID, Df: 8um, Nonpolar PLOT column incorporating 100% divinylbenzene. High retention for CO2 simplifies gas analysis; CO2 and methane separated from O2/N2/CO, for analysis of oxygenated compounds and solvents. Temperature of 300 deg C

MXT-502.2 Column 3um. MXT-502.2 Column, Length: 30m, ID: 0.28mm, Df: 1.60um, proprietary Crossbond diphenyl/dimethyl polysiloxane phase, Application-specific columns with unique selectivity for volatile organic pollutants, Temperature range: -20 deg C to 320 deg C.

MXT-1701 Column 0.25um. MXT-1701 Column, Siltek-treated stainless steel, Length: 30M, ID: 0.25mm, Df: 0.25um, 6in Config. For MXT columns without Cage, General-purpose columns for alcohols, oxygenates, PCB congeners and pesticides. 4.5in standard coil diameter. Similar Phase(s): DB-PS1701

Stabilwax Column 0.25um. Stabilwax Column, fused silica, with 10m Integra-Guard, Length: 30m, ID: 0.32mm, Df: 0.25um, For HP 6850 GCs, polar phase; Crossbond polyethylene glycol, Rugged enough to with stand repeated water injections. Temperature range: 40 deg C to 260 deg C.

Stabilwax Column 0.50um. Stabilwax Column, fused silica, with 10m Integra-Guard, Length: 30m, ID: 0.25mm, Df: 0.50um, For HP 6850 GCs, polar phase; Crossbond polyethylene glycol, Rugged enough to with stand repeated water injections. Temperature range: 40 deg C to 260 deg C.

Stabilwax Column 1um. Stabilwax Column, fused silica, with 10m Integra-Guard, Length: 60m, ID: 0.53mm, Df: 1um, For HP 6850 GCs, polar phase; Crossbond polyethylene glycol, Rugged enough to with stand repeated water injections. Temperature range: 40 deg C to 260 deg C.

Stabilwax Column 0.25um. Stabilwax Column, fused silica, with 5m Integra-Guard, Length: 30m, ID: 0.32mm, Df: 0.25um, For HP 6850 GCs, polar phase; Crossbond polyethylene glycol, Rugged enough to with stand repeated water injections. Temperature range: 40 deg C to 260 deg C.

Stabilwax Column 0.50um. Stabilwax Column, fused silica, with 5m Integra-Guard, Length: 30m, ID: 0.25mm, Df: 0.50um, For HP 6850 GCs, polar phase; Crossbond polyethylene glycol, Rugged enough to with stand repeated water injections. Temperature range: 40 deg C to 260 deg C.

Stabilwax Column 0.50um. Stabilwax Column, fused silica, with 5m Integra-Guard, Length: 30m, ID: 0.32mm, Df: 0.50um, For HP 6850 GCs, polar phase; Crossbond polyethylene glycol, Rugged enough to with stand repeated water injections. Temperature range: 40 deg C to 260 deg C.

Stabilwax Column 1um. Stabilwax Column, fused silica, with 5m Integra-Guard, Length: 30m, ID: 0.32mm, Df: 1um, For HP 6850 GCs, polar phase; Crossbond polyethylene glycol, Rugged enough to with stand repeated water injections. Temperature range: 40 deg C to 260 deg C.

Stabilwax Column 1um. Stabilwax Column, fused silica, with 5m Integra-Guard, Length: 30m, ID: 0.53mm, Df: 1um, For HP 6850 GCs, polar phase; Crossbond polyethylene glycol, Rugged enough to with stand repeated water injections. Temperature range: 40 deg C to 260 deg C.

Stabilwax Column 0.50um. Stabilwax Column, fused silica, with 5m Integra-Guard, Length: 60m, ID: 0.25mm, Df: 0.50um, For HP 6850 GCs, polar phase; Crossbond polyethylene glycol, Rugged enough to with stand repeated water injections. Temperature range: 40 deg C to 260 deg C.

Stabilwax Column 1um. Stabilwax Column, fused silica, with 5m Integra-Guard, Length: 15m, ID: 0.53mm, Df: 1um, For HP 6850 GCs, polar phase; Crossbond polyethylene glycol, Rugged enough to with stand repeated water injections. Temperature range: 40 deg C to 260 deg C.

Rtx-2887 Column 2.65um. Rtx-2887 Column, fused silica, with 10m Integra-Guard, Length: 10M, ID: 0.53mm, Df: 2.65um, nonpolar phase; Crossbond 100% dimethyl polysiloxane-for simulated distillation, Application-specific column for simulated distillation. Stable to 360 deg C. Similar Phase: DB-2887

Rtx-2887 Column 2.65um. Rtx-2887 Column, fused silica, with 5m Integra-Guard, Length: 10M, ID: 0.53mm, Df: 2.65um, nonpolar phase; Crossbond 100% dimethyl polysiloxane-for simulated distillation, Application-specific column for simulated distillation. Stable to 360 deg C.

Rtx-1701 Column 1um. Rtx-1701 Column, fused silica, Length: 30m, 0.32mm ID, Df: 1.00um, midpolarity Crossbond phase, General-purpose columns for alcohols, oxygenates, PCB congeners, pesticides, and fragrance compounds. Equivalent to USP G46 phase. Similar Phase(s): DB-1701P, DB-1701

Rtx-5MS-Low-Bleed GC-MS Column, 10m Integra-Guard, Length: 30M, ID: 0.32mm, Df: 0.25um, low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners essential oils

Rtx-5MS-Low-Bleed GC-MS Column, 10m Integra-Guard, Length: 30M, ID: 0.25mm, Df: 1um, low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners essential oils

Rtx-5MS-Low-Bleed GC-MS Column, 5m Integra-Guard, Length: 5M, ID: 0.25mm, Df: 0.25um, low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners essential oils

Rtx-5MS-Low-Bleed GC-MS Column, 10m Integra-Guard, Length: 30M, ID: 0.25mm, Df: 0.25um, low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, General purpose columns for drugs, solvent impurities, pesticides, hydrocarbons, PCB congeners essential oils

Rtx-BAC1 Column 1.80um. Rtx-BAC1 Column, fused silica, proprietary Crossbond phase, Length: 30M, ID: 0.32MM, Df: 1.80UM, for abused inhalant anesthetics, Y-hydroxybutyrate (GHB)/Y-butyrolactone (GBL), glycols, and common industrial solvents. Stable to 260 deg C. Similar Phase: DB-ALC1, DB-ALC2

Rtx-35 Column 0.25um. Rtx-35 Column, fused silica, with 10m Integra-Guard, Length: 30M, ID: 0.25mm, Df: 0.25um, midpolarity phase; Crossbond diphenyl dimethyl polysiloxane, General-purpose columns for organochlorine pesticides, PCB congeners, herbicides, pharmaceuticals, sterols

Rtx-624 Column 1.40um. Rtx-624 Column, fused silica, with 5m Integra-Guard, low- to midpolarity phase, Length: 30M, ID: 0.25mm, Df: 1.40um, Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants. -20 deg C to 240 deg C.

Rtx-35 Column 0.25um. Rtx-35 Column, fused silica, with 5m Integra-Guard, Length: 30M, ID: 0.25mm, Df: 0.25um, midpolarity phase; Crossbond diphenyl dimethyl polysiloxane, General-purpose columns for organochlorine pesticides, PCB congeners, herbicides, pharmaceuticals, sterols

Rtx-624 Column 1.40um. Rtx-624 Column, fused silica, Integra-Guard, low- to midpolarity phase, Length: 30M, ID: 0.25mm, Df: 1.40um, Application-specific columns for volatile organic pollutants. Recommended in U.S. EPA methods for volatile organic pollutants. Temperature: -20 deg C to 240 deg C.

Rtx-1 Column 3um. Rtx-1 Column, fused silica, Guard, Length: 15m, ID: 0.53mm, Df: 3um, nonpolar phase; Crossbond dimethyl polysiloxane, General-purpose columns for solvent impurities, PCB congeners, simulated distillation, arson accelerants, gases, natural gas odorants, sulfur compounds

Rtx-5 (G27) Column. Rtx-5 (G27) Column, fused silica, Length: 30M, ID: 0.32mm, Df: 0.25um, fused silica, low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, Equivalent to USP G27 and G36 phases. General-purpose columns for drugs, solvent impurities, Similar Phase(s): HP-5, DB-5

Rtx-5 (G27) Column 0.25um. Rtx-5 (G27) Column, fused silica, with 10m Integra-Guard, Length: 15M, ID: 0.25mm, Df: 0.25um, fused silica, low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, Equivalent to USP G27 and G36 phases. General-purpose columns for drugs, solvent impurities

Rtx-5 (G27) Column 0.25um. Rtx-5 (G27) Column, fused silica, with 30m Integra-Guard, Length: 15M, ID: 0.25mm, Df: 0.25um, fused silica, low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, Equivalent to USP G27 and G36 phases. General-purpose columns for drugs, solvent impurities

Rtx-5 (G27) Column 0.25um. Rtx-5 (G27) Column, fused silica, with 30m Integra-Guard, Length: 15M, ID: 0.32mm, Df: 0.25um, fused silica, low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, Equivalent to USP G27 and G36 phases. General-purpose columns for drugs, solvent impurities

Rtx-35 Column 0.50um. Rtx-35 Column, fused silica, with 5m Integra-Guard, Length: 30M, ID: 0.32mm, Df: 0.50um, midpolarity phase; Crossbond diphenyl dimethyl polysiloxane, General-purpose columns for organochlorine pesticides, PCB congeners, herbicides, pharmaceuticals, sterols

Siltek-Deactivated Guard/Retention Gap Columns/Transfer Lines, fused silica, Length: 10M, ID: 0.25mm, Tested with a comprehensive test mix, to ensure high inertness. 380deg C. Revolutionary deactivation process for superior inertness.

Siltek-Deactivated Guard/Retention Gap Columns/Transfer Lines, fused silica, Length: 10M, ID: 0.32mm, Tested with a comprehensive test mix, to ensure high inertness. 380deg C. Revolutionary deactivation process for superior inertness.

Siltek-Deactivated Guard/Retention Gap Columns/Transfer Lines, fused silica, Length: 5M, ID: 0.25mm, Tested with a comprehensive test mix, to ensure high inertness. 380 deg C. Revolutionary deactivation process for superior inertness.

Siltek-Deactivated Guard/Retention Gap Columns/Transfer Lines, fused silica, Length: 5M, ID: 0.53mm, Tested with a comprehensive test mix, to ensure high inertness. 380 deg C. Revolutionary deactivation process for superior inertness.

Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines, fused silica, Length: 10M, ID: 25mm, Tested with a comprehensive test mix, to ensure high inertness. Maximum temperature: 325 deg C.

Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines, fused silica, Length: 10M, ID: 53mm, Tested with a comprehensive test mix, to ensure high inertness. Maximum temperature: 325 deg C.

Rt-YDEXsa Column 0.25um. Rt-YDEXsa Column, fused silica, For HP 6850 GCs, Length: 30M, ID: 0.32mm, Df: 0.25um, 2,3-di-acetoxy-6-O-tert-butyl dimethylsilyl gamma cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane, Temperature Limits: 40 to 230 deg C

Rt-YDEXsa Column 0.25um. Rt-YDEXsa Column, fused silica, For HP 6850 GCs, Length: 30M, ID: 0.25mm, Df: 0.25um, 2,3-di-acetoxy-6-O-tert-butyl dimethylsilyl gamma cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane, Temperature Limits: 40 to 230 deg C

Rtx-1301 (G43) Column 3um. Rtx-1301 (G43) Column, fused silica, Length: 30M, ID: 0.53mm, Df: 3um, low- to midpolarity phase, General-purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds. Equivalent to USP G43 phase. Similar Phase(s): DB-1301

Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines. Deactivated, Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines, fused silica, ID: 0.05mm, Length: 5M, Tested with a comprehensive test mix, to ensure high inertness. Maximum temperature: 325 deg C.

Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines. Deactivated, Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines, fused silica, ID: 0.10mm, Length: 5M, Tested with a comprehensive test mix, to ensure high inertness. Maximum temperature: 325 deg C.

Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines. Deactivated, Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines, fused silica, ID: 0.15mm, Length: 5M, Tested with a comprehensive test mix, to ensure high inertness. Maximum temperature: 325 deg C.

Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines. Deactivated, Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines, fused silica, ID: 0.18mm, Length: 5M, Tested with a comprehensive test mix, to ensure high inertness. Maximum temperature: 325 deg C.

Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines. Deactivated, Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines, fused silica, ID: 0.25mm, Length: 5M, Tested with a comprehensive test mix, to ensure high inertness. Maximum temperature: 325 deg C.

Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines. Deactivated, Hydroguard Water-Resistant Guard/Retention Gap Columns/Transfer Lines, fused silica, ID: 0.32mm, Length: 5M, Tested with a comprehensive test mix, to ensure high inertness. Maximum Temperature: 325 deg C.

Intermediate-Polarity Deactivated Guard/Retention Gap Columns/Transfer Lines, fused silica, Length: 10M, ID: 0.53mm, Tested with a comprehensive test mix to ensure high inertness. Maximum temperature: 325 deg C.

Intermediate-Polarity Deactivated Guard/Retention Gap Columns/Transfer Lines, fused silica, Length: 10M, ID: 0.32mm, Tested with a comprehensive test mix to ensure high inertness. Maximum temperature: 325 deg C.

Intermediate-Polarity Deactivated Column 5m. Intermediate-Polarity Deactivated Guard/Retention Gap Column/Transfer Line (fused silica), Temperature: 325deg C, Nominal ID: 0.18mm, Nominal OD: 0.37 +/- 0.04 mm, Length: 5m, Application: to ensure high inertness, for chlorinated pesticide analysis

Siltek-Deactivated Guard/Retention Gap Column 10 m. Siltek-Deactivated Guard/Retention Gap Column/Transfer Lines (fused silica), Nominal Inner Diameter: 0.25 mm, Nominal Outer Diameter: 0.37 +/- 0.04 mm, Length: 30 m, Application: to ensure high inertness, Use with most common solvents.

Rt-BDEXcst Column 0.25um. Rt-BDEXcst Column (fused silica), cyclodextrin material added into 14% cyanopropylphenyl/86% dimethyl polysiloxane, Temperature: 40 to 230deg C, Length: 30 m, ID: 0.25 mm, df: 0.25um, Application: stationary phase for the fragrance industry & pharmaceutical applications

Hydroguard Water-Resistant Column 30m. Hydroguard Water-Resistant Guard/Retention Gap Column /Transfer Line/Tubing, fused silica, Temperature: 325deg C, Nominal ID: 0.25mm, Nominal OD: 0.37 +/- 0.04mm, Length: 30m, Application: Extend Column life by preventing degradation from steam-cleaning

Hydroguard Water-Resistant Column 30m. Hydroguard Water-Resistant Guard/Retention Gap Column /Transfer Line/Tubing, fused silica, Temperature: 325deg C, Nominal ID: 0.32mm, Nominal OD: 0.45 +/- 0.04mm, Length: 30m, Application: Extend Column life by preventing degradation from steam-cleaning

Hydroguard Water-Resistant Column 30m. Hydroguard Water-Resistant Guard/Retention Gap Column /Transfer Line/Tubing, fused silica, Temperature: 325deg C, Nominal ID: 0.53mm, Nominal OD: 0.69 +/- 0.05mm, Length: 30m, Application: Extend Column life by preventing degradation from steam-cleaning

Intermediate-Polarity Deactivated Column 0.15 mm. Intermediate-Polarity Deactivated Guard/Retention Gap Column s/Transfer Lines (fused silica), Temperature: 325 deg C, Nominal ID: 0.15 mm, Nominal OD: 0.363 +/- 0.012 mm, Length: 5m, Application: to ensure high inertness, Use with most common solvent

Siltek-Deactivated Column 5 m. Siltek-Deactivated Guard Column /Transfer Lines (fused silica), Temperature: 380deg C, Nominal ID: 0.32 mm, Nominal OD: 0.45 +/- 0.04 mm, Length: 5 m, Application: to ensure high inertness, for chlorinated pesticide analysis, Analyze active samples

Siltek-Deactivated Column 5 m. Siltek-Deactivated Guard Column /Transfer Lines (fused silica), Temperature: 380deg C, Nominal ID: 0.53 mm, Nominal OD: 0.45 +/- 0.04 mm, Length: 5 m, Application: to ensure high inertness, for chlorinated pesticide analysis, Analyze active samples

Stabilwax-DB Capillary Column 0.25 um. Stabilwax-DB Capillary Column (fused silica), polar phase; Crossbond base-deactivated Carbowax polyethylene glycol, Length: 60 m, ID: 0.32 mm, df: 0.25 um, Application: reduce adsorption, improve responses for basic compound, without analyte derivatization

Rtx-5 Amine Column 1um. Rtx-5 Amine Column (fused silica), low-polarity phase; Crossbond 5% diphenyl/95% dimethyl polysiloxane, Temperature: -60-300/315 deg C, ID: 0.32mm, Length: 30m, df: 1um, Application: analyzing basic/neutral/adsorptive compounds with oxygen groups susceptible to phenols

Rt-BDEXsm Column 0.25um. Rt-BDEXsm Column (fused silica), 2,3-di-O-methyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane, Temperature: 40-230deg C, Length: 30 m, ID: 0.32 mm, df: 0.25um, Application: for chiral compounds in essential oils

Rt-BDEXsm Column 0.25um. Rt-BDEXsm Column (fused silica), 2,3-di-O-methyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane, Temperature: 40-230deg C, Length: 30 m, ID: 0.25 mm, df: 0.25um, Application: for chiral compound in essential oils

Rt-BDEXse Column 0.25um. Rt-BDEXse Column fused silica, 2,3-di-O-ethyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane, Temperature: 40-230deg C, Length: 30m, ID: 0.32mm, df: 0.25um, Application: resolution for limonene, styrene oxides

Rt-BDEXse Column 0.25um. Rt-BDEXse Column (fused silica), 2,3-di-O-ethyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added into 14% cyanopropylphenyl/86% dimethyl polysiloxane, Temperature: 40-230deg C, Length: 30 m, ID: 0.25 mm, df: 0.25um, Application: resolution for limonene, styrene oxides

Rt-BDEXsa Column 0.25um. Rt-BDEXsa Column fused silica, 2,3-di-acetoxy-6-O-tert-butyl dimethylsilyl beta cyclodextrin added to 14% cyanopropylphenyl/86% dimethyl polysiloxane, Temperature: 40 to 230deg C, Length: 30m, ID: 0.32mm, df: 0.25um, Application: for ester, lactones, fruit flavor component

Rt-BDEXsa Column 0.25um. Rt-BDEXsa Column fused silica, 2,3-di-acetoxy-6-O-tert-butyl dimethylsilyl beta cyclodextrin added to 14% cyanopropylphenyl/86% dimethyl polysiloxane, Temperature: 40 to 230deg C, Length: 30m, ID: 0.25mm, df: 0.25um, Application: for ester, lactones, fruit flavor component

Rt-BDEXsp Column 0.25um. Rt-BDEXsp Column fused silica, 2,3-di-O-propyl-6-O-tert-butyl dimethylsilyl beta cyclodextrin added to 14% cyanopropylphenyl/86% dimethyl polysiloxane, Temperature: 40-230deg C, Length: 30m, ID: 0.25mm, df: 0.25um, Application: dual-Column, for enantiomeric separations

Rtx-1701 Column 0.25 um. Rtx-1701 Column s (fused silica), midpolarity Crossbond phase, Temperature: -20-260/280deg C, Length: 30 m, Internal Diameter: 0.25 mm, df: 0.25 um, Application: ensure long-term reproducibility, Column -to-Column consistency & low bleed, for alcohols, oxygenates

Rtx-5MS GC-MS Column 0.25um. Rtx-5MS Low-Bleed GC-MS Column s (fused silica), low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, Temperature: -60-330/350deg C, Length: 15m, ID: 0.25mm, df: 0.25um, Application: for drugs, solvent impurities, hydrocarbons, PCB congeners, essential oils

Intermediate-Polarity Deactivated Guard Column 5 m. Intermediate-Polarity Deactivated Guard Column, Temperature: 325deg C, Nominal Inner Diameter: 0.45mm, Nominal Outer Diameter: 0.69 +/- 0.05, Length: 5 m, Application: to ensure high inertness, Use with most common solvents.

Rtx-624 Column 1.80um. Rtx-624 Column s (fused silica), low- to midpolarity phase, Temperature:-20-240deg C, Length: 30m, Inner Diameter: 0.32mm, df: 1.80um, Application: for analyzing volatile organic pollutants (U.S. EPA method), resolution of early eluting compounds, Equivalent to USP G43 phase

Rtx-624 Column 3.00um. Rtx-624 Column s (fused silica), low- to midpolarity phase, Temperature:-20-240deg C, Length: 30m, Inner Diameter: 0.53mm, df: 3.00um, Application: for analyzing volatile organic pollutants (U.S. EPA method), resolution of early eluting compounds, Equivalent to USP G43 phase

Rtx-CLPesticides Column 0.25um. Rtx-CLPesticides Column s (fused silica), proprietary Crossbond phases, Temperature: -60-320/340deg C, Length: 30m, ID: 0.25mm, df: 0.25um, Application: Low bleed, To overcome the coelutions and analyte breakdown in organochlorine pesticides and herbicides

Rtx-CLPesticides Column 0.50um. Rtx-CLPesticides Column s (fused silica), proprietary Crossbond phases, Temperature: -60-320/340deg C, Length: 30m, ID: 0.32mm, df: 0.50um, Application: Low bleed, To overcome the coelutions and analyte breakdown in organochlorine pesticides and herbicides

Rtx-CLPesticides Column 0.50um. Rtx-CLPesticides Column s (fused silica), proprietary Crossbond phases, Temperature: -60-320/340deg C, Length: 30m, ID: 0.53 mm, df: 0.50um, Application: Low bleed, To overcome the coelutions and analyte breakdown in organochlorine pesticides and herbicides

Stabilwax-MS Column 0.25 um. Stabilwax-MS Column (fused silica), High-polarity, stable polyethylene glycol (PEG) stationary phase, Temperature: 40-250/260 deg C, Length: 30 m, ID: 0.25 mm, df: 0.25 um, Application: for purity testing of chemicals, impurities in water matrices, alcoholic beverages.

Siltek-Deactivated Column 10 m. Siltek-Deactivated Guard Column /Transfer Lines (fused silica), Temperature: 380deg C, Nominal ID: 0.53mm, Nominal OD: 0.69 +/- 0.05mm, Length: 10m, Application: to ensure high inertness, chlorinated pesticide analysis, Analyze tough sample quickly, Minimize bleed

Rtx-35 Column 0.50um. Rtx-35 Column s (fused silica), midpolarity phase; Crossbond diphenyl dimethyl polysiloxane, Temperature: 40-320deg C, Length: 30m, ID: 0.53mm, df: 0.50um, Application: for organochlorine pesticides, PCB congeners, herbicides, pharmaceuticals, rosin acids, phthalate esters

Rtx-5 DHA Tuning Column (fused silica) 1.00 um. Rtx-5 DHA Tuning Column (fused silica), Crossbond 5% diphenyl/95% dimethyl polysiloxane, Temperature: -60 - 325/350 deg C, Length: 5 m, Internal Diameter: 0.25 mm, df: 1.00 um, Application: for hydrocarbon analysis

Rtx-50 Column 1.00um. Rtx-50 Column (fused silica), midpolarity phase; Crossbond phenyl methyl polysiloxane, Temperature: 40 - 260/280 deg C, Length: 30 m, Internal Diameter: 0.53 mm, df: 1.00um, Application: dual-Column analysis, for pesticides, herbicides, rosin acids, phthalate esters, sterols

Rtx-Dioxin2 Column 0.18 um. Rtx-Dioxin2 Column (fused silica), proprietary Crossbond phase, Temperature: 20-320/340 deg C, ID: 0.18 mm, Length: 40 m, df: 0.18 um, Application: Unique selectivity for toxic dioxin and furan congeners, Isomer specificity for 2, 3, 7, 8-TCDD and 2, 3, 7, 8-TCDF

Rtx-35 Amine Column 0.50 um. Rtx-35 Amine Column (fused silica), midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane, Temperature: 0 to 220 deg C, Length: 15 m, ID: 0.25 mm, df: 0.50 um, Application: for neutral/adsorptive compound with oxygen group susceptible to hydrogen bonding

Rtx-35 Amine Column 1.0um. Rtx-35 Amine Column (fused silica), midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane, Temperature: 0 to 220 deg C, Length: 15 m, ID: 0.25 mm, df: 1.0um, Application: for neutral/adsorptive compound with oxygen group susceptible to hydrogen bonding

Rtx-35 Amine Column 1.0um. Rtx-35 Amine Column (fused silica), midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane, Temperature: 0 to 220 deg C, Length: 15 m, ID: 0.32 mm, df: 1.0um, Application: for neutral/adsorptive compound with oxygen group susceptible to hydrogen bonding

Rtx-35 Amine Column 1.0um. Rtx-35 Amine Column (fused silica), midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane, Temperature: 0 to 220 deg C, Length: 15 m, ID: 0.53 mm, df: 1.0um, Application: for neutral/adsorptive compound with oxygen group susceptible to hydrogen bonding

Rtx-35 Amine Column 1.0um. Rtx-35 Amine Column (fused silica), midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane, Temperature: 0 to 220 deg C, Length: 30 m, ID: 0.25 mm, df: 1.0um, Application: for neutral/adsorptive compound with oxygen group susceptible to hydrogen bonding

Rtx-35 Amine Column 1.0um. Rtx-35 Amine Column (fused silica), midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane, Temperature: 0 to 220 deg C, Length: 30 m, ID: 0.32 mm, df: 1.0um, Application: for neutral/adsorptive compound with oxygen group susceptible to hydrogen bonding

Rtx-35 Amine Column 1.0um. Rtx-35 Amine Column (fused silica), midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane, Temperature: 0 to 220 deg C, Length: 30 m, ID: 0.53 mm, df: 1.0um, Application: for neutral/adsorptive compound with oxygen group susceptible to hydrogen bonding

Rtx-35 Amine Column 1.5um. Rtx-35 Amine Column (fused silica), midpolarity phase; Crossbond 35% diphenyl/65% dimethyl polysiloxane, Temperature: 0 to 220 deg C, Length: 30 m, ID: 0.32 mm, df: 1.5um, Application: for neutral/adsorptive compound with oxygen group susceptible to hydrogen bonding

Rtx-5 Amine Column 0.25um. Rtx-5 Amine Column, fused silica, low-polarity phase; Crossbond 5% diphenyl/95% dimethyl polysiloxane, Temperature: -60-300/315deg C, ID: 0.25mm, Length: 15m, df: 0.25um, Application: analyzing basic/neutral/adsorptive compound with oxygen group susceptible to phenol

Stabilwax Capillary Column 0.25um. StabilwaxCapillary Column, polar phase; Crossbond polyethylene glycol, with 5m Integra-Guard, Temperature: 40-260deg C, ID: 0.25mm, Length: 60m, df: 0.25um, Application: purity testing of chemicals, analyzing impurities in water matrices & alcoholic beverages

Rtx-35 MS Capillary Column 0.25um. Rtx-35 MS Capillary Column, (Crossbond 35% diphenyl/65% dimethyl polysiloxane), with 5m Integra-Guard, Temperature: 40-320/340deg C, ID: 0.25mm, Length: 30m, df: 0.25um, Application: low-bleed, solvent impurities, hydrocarbon, essential oil, PCB congeners

Stabilwax Capillary Column 0.25um. StabilwaxCapillary Column, polar phase; Crossbond polyethylene glycol, with 10m Integra-Guard, Temperature: 40-260deg C, ID: 0.25mm, Length: 30m, df: 0.25um, Application: purity testing of chemical, analyzing impurities in water matrices & alcoholic beverages

Stabilwax Capillary Column 2.00um. StabilwaxCapillary Column, polar phase; Crossbond polyethylene glycol, with 5m Integra-Guard, Temperature: 40-260deg C, ID: 0.53mm, Length: 30m, df: 2.00um, Application: purity testing of chemicals, analyzing impurities in water matrices & alcoholic beverages

Rtx-5 (G27) Column 1um. Rtx-5 (G27) Column s (fused silica), low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, Temperature: -60-325/350 deg C, ID: 0.53mm, Length: 30m, df: 1um, Application: for drugs, solvent impurities, pesticides, PCB congeners, essential oils, semivolatiles.

Rtx-5 (G27) Column 0.25um. Rtx-5 (G27) Column s (fused silica), low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, Temperature: -60-325/350 deg C, ID: 0.25mm, Length: 15m, df: 0.25um, Application: for drugs, solvent impurities, pesticides, PCB congeners, essential oils, semivolatiles

Rtx-5 (G27) Column 5.00um. Rtx-5 (G27) Column s (fused silica), low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, Temperature: -60-325/350 deg C, ID: 0.53mm, Length: 30m, df: 5.00um, Application: for solvent impurities, pesticides, PCB congeners, essential oils, semivolatiles.

Rt-2340 NB Capillary Gas Chromatography Packed Column 0.20um. Rt-2340 NB Capillary Gas Chromatography Packed Column, Liquid phase, Temperature: 25-275 deg C, Inner Diameter: 0.32mm, Length: 60m, df: 0.20um

Category
  • Prev
  • 11
  • 12
  • 13
  • 14
  • 15
  • Next

We search our sources worldwide for the best values in medical products and select the best values. We offer them here so you can shop in confidence.

Useful Links

  • Support

Help

  • Home
  • About Us
  • Contact Us

Policy

  • Privacy policy
  • Terms and Conditions
  • Return Policy
  • Refund Policy

Copyright® 2016 - 2025 RELIANCE INC | All rights reserved.

Icon