About Us
Login
Retail Customer Login
Business User Login
Registration
Retail Customer Registration
Business User Registration
0
Shop Products
Ambulatory Equipment
Apparel
Appliances (Durable Goods)
Body Pressure Relief and Positioning
Clinical Laboratory
Diagnostic Instruments and Supplies
Drainage and Suction
Furnishings
Gloves
Housekeeping
Implants
Incontinence
Indicators and Signage
Instruments
IV Therapy
Needles and Syringes
Nurse's Station and Office Supplies
Nutritionals and Feeding Supplies
Orthopedic
Ostomy
other
Personal Hygiene
Pharmaceuticals
Physical Therapy
Respiratory
Services
Sterilization
Textiles
Training and Education
Urological
Utensils
Ventilators
Wound Care
Wound Closure
0
Retail Customer Login
Business User Login
Retail Customer Registration
Business User Registration
Shop Products
Ambulatory Equipment
Apparel
Appliances (Durable Goods)
Body Pressure Relief and Positioning
Clinical Laboratory
Diagnostic Instruments and Supplies
Drainage and Suction
Furnishings
Gloves
Housekeeping
Implants
Incontinence
Indicators and Signage
Instruments
IV Therapy
Needles and Syringes
Nurse's Station and Office Supplies
Nutritionals and Feeding Supplies
Orthopedic
Ostomy
other
Personal Hygiene
Pharmaceuticals
Physical Therapy
Respiratory
Services
Sterilization
Textiles
Training and Education
Urological
Utensils
Ventilators
Wound Care
Wound Closure
$
Go Back
MXT 5 Column 60m. MXT 5 Column, Siltek treated stainless steel, low-polarity phase, Crossbond diphenyl dimethyl polysiloxane, Temperature Range: -60-360 deg C, Equivalent to USP G27, G36 phases, General-purpose, 4.5in standard coil diameter, Length: 60m, Internal Diameter: 0.53mm, df: 3.00um
MXT 1 Column 10m. MXT 1 Column, Siltek treated stainless steel, nonpolar phase, Crossbond dimethyl polysiloxane, Temperature range: -60-430 Deg C, Equivalent to USP G1, G2, G38 phases, 4.5in standard coil diameter, for solvent impurities, Length: 10m, Internal Diameter: 0.18mm, df: 0.20um
MXT 1 Column 20m. MXT 1 Column, Siltek treated stainless steel, nonpolar phase, Crossbond dimethyl polysiloxane, Temperature range: -60-430 Deg C, Equivalent to USP G1, G2, G38 phases, 4.5in standard coil diameter, for solvent impurities, Length: 20m, Internal Diameter: 0.18mm, df: 0.20um
MXT 1 Column 20m. MXT 1 Column, Siltek treated stainless steel, nonpolar phase, Crossbond dimethyl polysiloxane, Temperature range: -60-430 Deg C, Equivalent to USP G1, G2, G38 phases, 4.5in standard coil diameter, for solvent impurities, Length: 20m, Internal Diameter: 0.18mm, df: 0.40um
MXT 5 Column 10m. MXT 5 Column, Siltek treated stainless steel, low-polarity phase, Crossbond diphenyl dimethyl polysiloxane, Temperature Range: -60-360 deg C, Equivalent to USP G27, G36 phases, General-purpose, 4.5in standard coil diameter, Length: 10m, Internal Diameter: 0.18mm, df: 0.20um
MXT 5 Column 20m. MXT 5 Column, Siltek treated stainless steel, low-polarity phase, Crossbond diphenyl dimethyl polysiloxane, Temperature Range: -60-360 deg C, Equivalent to USP G27, G36 phases, General-purpose, 4.5in standard coil diameter, Length: 20m, Internal Diameter: 0.18mm, df: 0.20um
MXT 5 Column 40m. MXT 5 Column, Siltek treated stainless steel, low-polarity phase, Crossbond diphenyl dimethyl polysiloxane, Temperature Range: -60-360 deg C, Equivalent to USP G27, G36 phases, General-purpose, 4.5in standard coil diameter, Length: 40m, Internal Diameter: 0.18mm, df: 0.20um
MXT 5 Column 10m. MXT 5 Column, Siltek treated stainless steel, low-polarity phase, Crossbond diphenyl dimethyl polysiloxane, Temperature Range: -60-360 deg C, Equivalent to USP G27, G36 phases, General-purpose, 4.5in standard coil diameter, Length: 10m, Internal Diameter: 0.18mm, df: 0.40um
MXT 5 Column 20m. MXT 5 Column, Siltek treated stainless steel, low-polarity phase, Crossbond diphenyl dimethyl polysiloxane, Temperature Range: -60-360 deg C, Equivalent to USP G27, G36 phases, General-purpose, 4.5in standard coil diameter, Length: 20m, Internal Diameter: 0.18mm, df: 0.40um
MXT 1 Column 30m. MXT 1 Column, Siltek treated stainless steel, nonpolar phase, Crossbond dimethyl polysiloxane, Temperature range: -60-430 Deg C, Equivalent to USP G1, G2, G38 phases, 4.5in standard coil diameter, for solvent impurities, Length: 30m, Internal Diameter: 0.32mm, df: 4.00um
MXT Guard/Retention Gap Column. Intermediate-Polarity Deactivated MXT Guard/Retention Gap Column/Transfer Lines, passivated stainless steel, Temperature range: 325 deg C, Useful for a wide range of applications, Nominal ID: 0.28mm, Nominal OD: 0.56 +/- 0.025mm, Length: 10 m
MXT Guard/Retention Gap Column. Intermediate-Polarity Deactivated MXT Guard/Retention Gap Column/Transfer Lines, passivated stainless steel, Temperature range: 325 deg C, Useful for a wide range of applications, Nominal ID: 0.53mm, Nominal OD: 0.56 +/- 0.025mm, Length: 10 m
MXT 1 Column 6m. MXT 1 Column, Siltek treated stainless steel, nonpolar phase, Crossbond dimethyl polysiloxane, Temperature range: -60-430 Deg C, Equivalent to USP G1, G2, G38 phases, 4.5in standard coil diameter, for solvent impurities, Length: 6m, Internal Diameter: 0.28mm, df: 0.1um
Intermediate-Polarity Deactivated Guard/Retention Gap Column/Transfer Lines, fused silica, Tested with a comprehensive test mix to ensure high inertness, Useful for a wide range of applications, Nominal ID: 0.10mm, Nominal OD: 0.363 +/- 0.012mm, Length: 5 m
Rtx Dioxin2 Column 60m. Rtx Dioxin2 Column, fused silica, proprietary Crossbond phase, Temperature Range: 20 to 340 deg C, Unique selectivity for toxic dioxin and furan congeners allows use as a confirmation GC column, Length: 60m, Internal Diameter: 0.25mm, df: 0.25um
Stx CLPesticides 2 Column 30m. Stx CLPesticides2 Column, fused silica with Siltek deactivation, proprietary Crossbond phases, Application-specific Column for organochlorine pesticides and herbicides, Temperature range: -60 to 330 deg C, Length: 30 m, Internal Diameter: 0.32mm, df: 0.25um
Rtx 220MS Column 30m. Rtx 220MS Low-Bleed GC-MS Column, fused silica, midpolarity phase, Crossbond trifluoropropylmethyl polysiloxane, Temperature range: -20 Deg C to 340 Deg C, Equivalent to USP G6 phase, for solvents, Freon fluorocarbons, Length: 30m, Internal Diameter: 0.32mm, df: 0.25um
Stx-CLPesticides Column, fused silica with Siltek deactivation, proprietary Crossbond phases, Application-specific Column for organochlorine pesticides and herbicides, Temperature range: -60 to 330 deg C, Length: 30 m, Internal Diameter: 0.32mm, df: 0.50um
Rxi XLB Column 30m. Rxi XLB Column, fused silica, nonpolar phase, Crossbond dimethyl polysiloxane, low-polarity proprietary phase, Temperature range: 30 Deg C to 360 Deg C, for many GC-MS applications, including pesticides, PCB congeners, Length: 30m, Internal Diameter: 0.25mm, df: 0.25um
Rtx 1 Column30m. Rtx 1 Column, fused silica, nonpolar phase, Crossbond dimethyl polysiloxane, Temperature Range: -60 -340 deg C, Equivalent to USP G1, G2, G38 phases, for solvent impurities, PCB congeners, simulated distillation, Length: 30mInternal Diameter: 0.32mm, Df: 5.00um
Rxi Guard Column 5m. Rxi Guard Column, fused silica, nonpolar phase, Crossbond dimethyl polysiloxane, Extend column lifetime, Excellent inertness-obtain lower detection limits for active compounds, Sharper chromatographic peaks, Length: 5m, Nominal ID: 0.25mm, Nominal OD: 0.37 +/- 0.04mm
Ferrule Replacement Polyimide. Ferrule Replacement, for connecting transfer line to EZ No-Vent connector, Material: Polyimide, ID: 0.4 mm
Graphite Ferrule 0.5 mm. Graphite Ferrule, Fits Column ID: 0.32 mm, Material: Graphite, Fitting Size: 1/16in, Ferrule ID: 0.5 mm, High-purity, high-density graphite, Stable to 450 deg C, M4 Fitting for Fisons 8000 GC and Trace 2000, with Smooth surface and clean edges, for Vu2 Union Connector
Graphite Ferrule 0.8 mm. Graphite Ferrule, Fits Column ID: 0.45-0.53 mm, Material: Graphite, Fitting Size: 1/16in, Ferrule ID: 0.8 mm, High-purity, high-density graphite, Stable to 450 deg C, M4 Fitting for Fisons 8000 GC and Trace 2000, with Smooth surface and clean edges, for Vu2 Union Connector
Standard Ferrule 1/16in. Standard Ferrule, Material: VG2, 60% Vespel/40% Graphite, Fitting Size: 1/4in, Ferrule ID: reduce to 1/16in, Seal with minimal torque, reusable, and for vacuum and high-pressure uses, Stable to 400 deg C, for mass spectroscopy transfer lines, also for 1/16, 1/8 Fittings
Capillary Ferrule 0.6 mm. Capillary Ferrule, Material: VG2, 60% Vespel/40% Graphite, Fits Column ID: 0.28 mm, ferrule ID: 0.6 mm, for 1/16In Compression-Type Fittings, For micropacked column, Seal with minimal torque, reusable, and preferred for vacuum and high-pressure uses, Stable to 400 deg C
Ferrule 1/16in. Ferrule, Adaptor, Material: Virgin Polyimide, graphite-reinforced composite, Tubing OD: 0.40 less than or equal to 0.50mm, to maximize mechanical stability at 350 deg C temperature, with tight tolerance, for EZ No-Vent GC Column-MS Connectors, determined by fused silica tubing OD
Graphite Sealing Ring, for Thermo Scientific TRACE, 8000, 8000 TOP and Focus SSL instrument, fits 8 mm Outer Diameter liners, Maximum Temperature: 450 degree C
O-Ring Graphite. O-Ring, Material: Graphite, Maximum Temperature: 450 deg C, Fits 4 mm OD liner, for PerkinElmer Auto SYS XL or Clarus gas chromatography With PSS Injector
Reducing Ferrule 0.5 mm. Reducing Ferrule, Fits Column ID: 0.32 mm, Ferrule ID: 0.5 mm, Material: Graphite, Fitting Size: 1/4in, Preconditioned to eliminate outgassing, High-purity, high-density graphite, Smoother surface and cleaner edges than conventional graphite ferrule, Stable to 450 deg C
Encapsulated Ferrule 0.5 mm. Encapsulated Ferrule, Fits Column ID: 0.32 mm, Material: Graphite, Ferrule ID: 0.5 mm, for 1/16-Inch Compression Fitting, Reusable-will not deform and stick in fitting, Less torque needed to seal ferrule, unique blend of graphite minimizes fragmentation and out-gassing
Encapsulated Ferrule 0.8 mm. Encapsulated Ferrule, Fits Column ID: 0.53 mm, Material: Graphite, Ferrule ID: 0.8 mm, for 1/16-Inch Compression Fitting, Reusable-will not deform and stick in fitting, Less torque needed to seal ferrule, unique blend of graphite minimizes fragmentation and out-gassing
Ferrule, Material: Vespel/Graphite, Fitting Size: 1/32in, Ferrule Inner Diameter: 0.4 mm.
Liner Seal, for CIS4 and PTV instrument, Maximum Temperature: 450 degree C.
Ferrule 0.5 mm. Ferrule, Fits Column ID: 0.32 mm, Material: Graphite, Fitting Size: 1/16in, Ferrule ID: 0.5 mm, Compression-Type Fitting, Preconditioned to eliminate outgassing, High-purity, high-density graphite, Smoother surface, cleaner edges, conventional graphite ferrules, Stable to 450 deg C
Ferrule 1.0 mm. Ferrule, Fits Column ID: 0.75 mm, Material: Graphite, Fitting Size: 1/16in, Ferrule ID: 1 mm, Compression-Type Fitting, Preconditioned to eliminate outgassing, High-purity, high-density graphite, Smoother surface and cleaner edges, conventional graphite ferrules, Stable to 450 deg C
Ferrule for Micropacked Column 1.0 mm. Ferrule for Micropacked Column, Compact, Ferrule Inner Diameter: 1.0 mm, Fits Column Inner Diameter: 0.75 mm, Material: Graphite, for Agilent 5890/6890/6850/7890 Gas chromatography
Ferrule 1mm. Ferrule for Micropacked Column, Fits Column ID: 1.00 mm, Material: Graphite, Fitting Size: 1/16in Compression-Type Fitting, Preconditioned to eliminate outgassing, High-purity, high-density graphite, Smoother surface and cleaner edge, conventional graphite ferrule, Stable to 450 deg C
Ferrule for Micropacked Column 1.00 mm. Ferrule for Micropacked Column, Compact, Fits Column ID: 1.00 mm, Material: Graphite, Ferrule ID: 1.6 mm, for Agilent 5890/6890/6850/7890 Gas chromatography,
Capillary Ferrule 0.4 mm. Capillary Ferrule, Material: Vespel, Fits Column ID: 0.10/0.15/0.18/0.25/0.28 mm Fused Silica Column, Fitting Size: 1/16in Compression-Type Fitting, Ferrule Inner Diameter: 0.4 mm, 100% high-temperature polyimide, Stable to 350 deg C, Durable, leak-tight.
Capillary Ferrule 0.5 mm. Capillary Ferrule, Material: Vespel, Fits Column ID: 0.32 mm, Fitting Size: 1/16in Compression-Type Fitting, Ferrule Inner Diameter: 0.5 mm, 100% high-temperature polyimide, Stable to 350 deg C, Durable, leak-tight.
Capillary Ferrule 0.8 mm. Capillary Ferrule, Material: Vespel, Fits Column ID: 0.45/0.53 mm, Fitting Size: 1/16in Compression-Type Fitting, Ferrule Inner Diameter: 0.8 mm, 100% high-temperature polyimide, Stable to 350 deg C, Durable, leak-tight.
Capillary Ferrule 1.0 mm. Capillary Ferrule, Material: Vespel, Fits Column ID: 0.75 mm micropacked, Fitting Size: 1/16in Compression-Type Fitting, Ferrule Inner Diameter: 1.0 mm, 100% high-temperature polyimide, Stable to 350 deg C, Durable, leak-tight.
Alumaseal Ferrule 0.8 mm. Alumaseal Ferrule, Fits Column Inner Diameter: 0.53 mm, Ferrule ID: 0.8 mm, Aluminum construction will not crack or fragment, Stable to 550 deg C, Use with any 1/16in compression-type fitting, Will not stick in fittings, unlike Vespel or graphite ferrule
Ferrule PTFE 3/16in. Ferrule, Material: PTFE, Fitting Size: 3/16in, Ferrule inner Diameter: 3/16in, Upper temperature limit 250 deg C, 100% PTFE, completely inert, One-piece design requires no back ferrule
Capillary GC Column Cutter. Shortix Capillary GC Column Cutter, Consistently make precise, clean, square cuts with a diamond blade, Built-in magnifier to verify square cut, Use with 0.25 mm ID to 0.53 mm ID tubing (0.78 mm OD maximum)
Rethreading Tool, Benefits and Uses: for 1/4 inch compression fittings (split/splitless injection ports), Repair worn or damaged threads, Multiple uses (fittings, injectors, detectors, etc.), Built-in guide to prevent cross-threading
SSI Replacement Cutting Wheel for TC-20 Tube Cutting Machine.
Capillary Column Cap Glass. Capillary Column Cap, Material: Glass, Increase column lifetime-prevent moisture and air from entering the column during storage, color-coded for identifying detector and injector ends, Attach to the column in seconds to form an airtight seal.
Septum Nut Removal Tool, for 5890/6850/6890/7890 GCs, Easily remove the septum nut without touching the heated nut, Unique, ergonomic handle-easy to grip, Nut remains in tool for quick reattachment
Inlet Wrench, for 17A, 2010 and 2014 GCs, Designed specifically for removing Shimadzu injection ports, High-quality stainless steel construction
Flexible Inspection Light, Inspect inside surfaces of sample cylinders or other chambers, 14 inch reach, 100,000-hour LED life
Replacement Cutting Wheels for Ridgid Tubing Cutter.
Rethreading Tool, Benefits and Uses: for 1/16 inch compression fitting, Repair worn or damaged threads, Multiple uses (fittings, injectors, detectors, etc.), Built-in guide to prevent cross-threading
Rethreading Tool, Benefits and Uses: for 1/8 inch compression fitting, Repair worn or damaged threads, Multiple uses (fittings, injectors, detectors, etc.), Built-in guide to prevent cross-threading
Make Life Easier (MLE) Capillary Tool Kit for GCs.
Make Life Easier (MLE) Capillary Tool Kit for GCs.
Replacement Inserts, for 1/8inch Tubing Dressing Tool.
High-Temperature String, Use to restring capillary columns, attach column connectors to column cages or hold the column in the GC oven. Capable of withstanding temperatures to 400 deg C
Make Life Easier (MLE) Capillary Tool Kit for GCs.
Make Life Easier (MLE) Capillary Tool Kit for GCs.
Maintenance Kit for Capillary GC Column Cutter. Maintenance Kit for Shortix Capillary GC Column Cutter, Includes: diamond cutting wheel, O-rings and a tool to open the column cutter
Magnetic Screwdriver 5-in-1, Magnetic power tip holds bits and screws securely.
File Needle. MXT Needle File, Multi-purpose files especially useful for cutting Siltek treated stainless steel columns
Wrench Set, Includes 4-inch, 6-inch and 8-inch adjustable wrench.
Oven Thermometer. GC Oven Thermometer, Verify GC oven temperature, Quick measurements via sensor in the measuring tip, Swivel head can turn 180 deg, Wide measuring range: -50 degree C to +350 degree C.
Tool Kit 54-Piece, notebook-style, Includes: Extension blade, Handle, driver blades, Hemostat, Hexdriver blades, Knife, Nutdriver blades, Penlight, Pliers, Rule,
Sapphire Scribe, Cuts fused silica tubing, Produces a clean, square cut, One quick stroke and tap leaves a clean, square end
Male Pipe to Valco Internal Adapter 1.0 mm. Male Pipe to Valco Internal Adapter, Union Bore: 1.0 mm, Material: Stainless steel, Size: 1/8inch NPT Male to 1/16inch ZDV, Makes a minimum volume connection from female pipe fitting on a pressure gauge/regulator to a Valco zero-dead-volume fitting
Male Pipe to Valco Internal Adapter 1.0 mm. Male Pipe to Valco Internal Adapter, Union Bore: 1.0 mm, Material: Stainless steel, Size: 1/4inch NPT Male to 1/16inch ZDV, Makes a minimum volume connection from female pipe fitting on a pressure gauge/regulator to a Valco zero-dead-volume fitting
Valco Internal Reducing Union 0.25 mm. Zero-Dead-Volume Valco Internal Reducing Union, Union Bore: 0.25 mm, Connect two sizes of tubing, using zero-dead-volume fittings on each end. For 1/8inch to 1/16inch OD tubing, Stainless steel ferrules included, tight tolerances and premium quality
Valco Internal Reducing Union 0.75 mm. Zero-Dead-Volume Valco Internal Reducing Union, Union Bore: 0.75 mm, Connect two sizes of tubing, using zero-dead-volume fittings on each end. For 1/8inch to 1/16inch OD tubing, Stainless steel ferrules included, tight tolerances and premium quality
Valco Internal Reducing Union 1/16inch. Zero-Dead-Volume Valco Internal Reducing Union, Union Bore: 1/16inch, Connect two sizes of tubing, using zero-dead-volume fittings on each end. For 1/8inch to 1/16inch OD tubing, Stainless steel ferrules included, tight tolerances and premium quality
PressFit Connector. Defined PressFit Connector, Material: Borosilicate Glass (Deactivated), Fits Column ID: For 0.18/0.25mm - 0.18/0.25mm ID Columns, Color: Red to Red (end codes), ID-specific ends for better sealabilit, Repair a broken column, Connect guard column to analytical column
MXT Y -Union Connector Kit, Fits Column ID: For 0.53 mm ID Columns, Siltek, Includes: MXT union, 1/32-inch nuts (3) and one-piece, fused silica adaptors (3), for Connecting Metal and/or Fused Silica GC Columns, Low-dead-volume, leak-tight connection, Reusable
MXT Y -Union Connector Kit, Fits Column ID: For 0.32 mm ID Columns, Siltek, Includes: MXT union, 1/32-inch nuts (3) and one-piece, fused silica adaptors (3), for Connecting Metal and/or Fused Silica GC Columns, Low-dead-volume, leak-tight connection, Reusable
PressFit Connector. Defined PressFit Connector, Material: Borosilicate Glass (Deactivated), Fits Column Internal Diameter: For 0.18/0.25 mm to 0.53 mm ID Columns, Color: Red to Blue (end codes), ID-specific ends for better sealabilit, Repair a broken column, Connect guard column to analytical column
Valco Adaptor Ferrule 1/32-Inch. Valco Adaptor Ferrules, Fused silica adaptor ferrules, Material: Valcon Polyimide, Tubing ID: 0.25 mm; OD: 0.25 Less than or equal to 0.40 mm, unique, graphite-reinforced composite maximize mechanical stability at temperatures up to 350 degree C, Size: 1/32inch
Valco Adaptor Ferrule 1/16-Inch. Valco Adaptor Ferrules, Fused silica adaptor ferrules, Material: Valcon Polyimide, Tubing OD: 0.30 Less than or equal to 0.40 mm, unique, graphite-reinforced composite prepared to maximize mechanical stability at temperature up to 350 degree C, Size: 1/16inch
Valco Adaptor Ferrule 1/16-Inch. Valco Adaptor Ferrules, Fused silica adaptor ferrules, Material: Valcon Polyimide, Tubing OD: 0.80 Less than or equal to 0.90 mm, unique, graphite-reinforced composite prepared to maximize mechanical stability at temperatures up to 350 degree C, Size: 1/16inch
Valco Adaptor Ferrule 1/16-Inch. Valco Adaptor Ferrules, Fused silica adaptor ferrules, Material: Valcon Polyimide, Tubing OD: 0.40 Less than or equal to 0.50 mm, unique, graphite-reinforced composite prepared to maximize mechanical stability at temperatures up to 350 degree C, Size: 1/16inch
Valco Adaptor Ferrule 1/16-Inch. Valco Adaptor Ferrules, Fused silica adaptor ferrules, Material: Valcon Polyimide, Tubing OD: 0.50 Less than or equal to 0.80 mm, unique, graphite-reinforced composite prepared to maximize mechanical stability at temperatures up to 350 degree C, Size: 1/16inch
MXT Low Dead Volume Connector for use with Fused Silica Capillary Columns, Union, Siltek For 0.53mm ID Fused Silica Columns, Ideal for connecting a guard column or transfer line to an analytical column, Reusable, Use to oven temperatures of 350 deg C
MXT Low Dead Volume Connector for use with Fused Silica Capillary Columns, Union, Siltek For 0.32mm ID Fused Silica Columns, Ideal for connecting a guard column or transfer line to an analytical column, Reusable, Use to oven temperatures of 350 deg C
Valco Internal Union 0.15 mm. Zero Dead Volume Valco Internal Union, Union Bore: 0.15 mm, Material: 300-series stainless steel, Ends of tubing seat squarely at bottoms of fitting details, For use with 1/16inch OD tubing, Stainless steel ferrules included, tight tolerances and premium quality
Valco Internal Union 0.75 mm. Zero Dead Volume Valco Internal Union, Union Bore: 0.75 mm, Material: 300-series stainless steel, Ends of tubing seat squarely at bottoms of fitting details, For use with 1/16inch OD tubing, Stainless steel ferrules included, tight tolerances and premium quality
Press-Tight Connector. Universal Press-Tight Connector, Siltek Deactivated, fused quartz helps eliminate activity for complete inertness along the GC flow path, Universal fit: use with 0.1-0.53 mm ID columns (0.33-0.74 mm OD), ideal for organochlorine pesticides analysis, Repair a broken column.
Angled Y Press-Tight Connector. Universal Angled Y Press-Tight Connector, Siltek Deactivated, fused quartz eliminate activity for complete inertness along the GC flow path, Universal fit: use with 0.1-0.53 mm ID columns (0.33-0.74 mm OD), ideal for organochlorine pesticides analysis
Valco Internal Tee 0.25 mm. Zero-Dead-Volume Valco Internal Tee, Union Bore: 0.25 mm, Material: 300 series stainless steel, Connect three lines, For 1/16inch OD tubing, stainless steel ferrules included, designed for the specific instrumentation with the tight tolerances and premium quality
Valco Internal Tee 0.75 mm. Zero-Dead-Volume Valco Internal Tee, Union Bore: 0.75 mm, Material: 300 series stainless steel, Connect three lines, For 1/16inch OD tubing, stainless steel ferrules included, designed for the specific instrumentation with the tight tolerances and premium quality
Valco Internal Cross 0.25 mm. Zero-Dead-Volume Valco Internal Cross, Union Bore: 0.25 mm, Material: 300 series stainless steel, Connect four lines, For 1/16inch OD tubing, stainless steel ferrules included, designed for the specific instrumentation with the tight tolerances and premium quality
Valco Internal Cross 0.75 mm. Zero-Dead-Volume Valco Internal Cross, Union Bore: 0.75 mm, Material: 300 series stainless steel, Connect four lines, For 1/16inch OD tubing, stainless steel ferrules included, designed for the specific instrumentation with the tight tolerances and premium quality
Universal Y Press-Tight Connectors, Deactivated fused quartz eliminate activity for complete inertness along the GC flow path, Universal fit: use with 0.1-0.53 mm ID columns (0.33-0.74 mm OD), ideal for organochlorine pesticides analysis, Split sample flow
Ferrule Replacement 1/32-Inch. Ferrule Replacement for MXT Connectors, Ferrule Internal Diameter: 0.53 mm, Fits Column Internal Diameter: 0.32 mm, Material: Stainless Steel, Fitting Size: 1/32inch, GC Accessories
GRAPHPACK 3D/2 Ferrule 0.5 mm. GRAPHPACK 3D/2 Ferrules, Ferrule Internal Diameter: 0.8 mm, Fits Column Internal Diameter: 0.45/0.53 mm, Quickly and reliably makes a leak-tight, low-dead-volume connection, The central component is a metal-jacketed graphite ferrule, Application: GC
Angled Y Press-Tight Connector. Universal Angled Y Press-Tight Connector, Deactivation: Deactivated, fused quartz eliminate activity for complete inertness along the GC flow path, Universal fit: use with 0.1-0.53 mm ID columns (0.33-0.74 mm OD), ideal for organochlorine pesticides analysis
Y Press-Tight Connector. Universal Y Press-Tight Connectors, Siltek Deactivated, fused quartz eliminate activity for complete inertness along the GC flow path, Universal fit: use with 0.1-0.53 mm ID columns (0.33-0.74 mm OD), ideal for organochlorine pesticides analysis, Split sample flow
Press-Tight Connector. Universal Press-Tight Connector, fused quartz helps eliminate activity for complete inertness along the GC flow path, Universal fit: use with 0.1-0.53 mm ID columns (0.33-0.74 mm OD), ideal for organochlorine pesticides analysis, Repair a broken column.
MXT Low Dead Volume Y Connector Kit, Siltek Fits Column Internal Diameter: For 0.53 mm ID MXT Columns, Includes: MXT union, 1/32-inch ferrules (3) and nuts (3), For Metal Columns, Connect two MXT columns to one inlet or one MXT column to two detectors
MXT Low Dead Volume Connector Kit, Fits Column ID: For 0.53 mm ID MXT Columns, Includes: MXT union, 1/32-inch ferrules (2) and nuts (2), for Metal Columns, Connect a guard column/transfer line to an MXT stainless steel column, Stainless steel ferrules and nuts
Category
Ambulatory Equipment
Apparel
Appliances (Durable Goods)
Body Pressure Relief and Positioning
Clinical Laboratory
Diagnostic Instruments and Supplies
Drainage and Suction
Furnishings
Gloves
Housekeeping
Implants
Incontinence
Indicators and Signage
Instruments
IV Therapy
Needles and Syringes
Nurse's Station and Office Supplies
Nutritionals and Feeding Supplies
Orthopedic
Ostomy
other
Personal Hygiene
Pharmaceuticals
Physical Therapy
Respiratory
Services
Sterilization
Textiles
Training and Education
Urological
Utensils
Ventilators
Wound Care
Wound Closure
Prev
15
16
17
18
19
Next