About Us
Login
Retail Customer Login
Business User Login
Registration
Retail Customer Registration
Business User Registration
0
Shop Products
Ambulatory Equipment
Apparel
Appliances (Durable Goods)
Body Pressure Relief and Positioning
Clinical Laboratory
Diagnostic Instruments and Supplies
Drainage and Suction
Furnishings
Gloves
Housekeeping
Implants
Incontinence
Indicators and Signage
Instruments
IV Therapy
Needles and Syringes
Nurse's Station and Office Supplies
Nutritionals and Feeding Supplies
Orthopedic
Ostomy
other
Personal Hygiene
Pharmaceuticals
Physical Therapy
Respiratory
Services
Sterilization
Textiles
Training and Education
Urological
Utensils
Ventilators
Wound Care
Wound Closure
0
Retail Customer Login
Business User Login
Retail Customer Registration
Business User Registration
Shop Products
Ambulatory Equipment
Apparel
Appliances (Durable Goods)
Body Pressure Relief and Positioning
Clinical Laboratory
Diagnostic Instruments and Supplies
Drainage and Suction
Furnishings
Gloves
Housekeeping
Implants
Incontinence
Indicators and Signage
Instruments
IV Therapy
Needles and Syringes
Nurse's Station and Office Supplies
Nutritionals and Feeding Supplies
Orthopedic
Ostomy
other
Personal Hygiene
Pharmaceuticals
Physical Therapy
Respiratory
Services
Sterilization
Textiles
Training and Education
Urological
Utensils
Ventilators
Wound Care
Wound Closure
$
Go Back
Nut and Washer, FID Collector, Replacement Parts for FID Collector Assembly Kit.
Ferrule, Upper temp. limit 250 C, 100% PTFE; completely inert, ID: 0.8mm, Fitting Size: 1/4in.
Ferrule, Upper temp. limit 250 C, 100% PTFE; completely inert, ID: 0.8mm, Fitting Size: 1/8in.
Ferrule, Upper temp. limit 250 C, 100% PTFE; completely inert, ID: 0.8mm, Fitting Size: 1/16in.
Ferrule. Upper temperature limit 250 DegreeC, 100% PTFE; completely inert, One-piece design requires no back ferrule.
Ferrule, for use with packed Column, Graphite construction 5mm.
Liner. Straight Inlet, 2.0mm ID, Length: 120mm, Deactivation: Intermediate Polarity (IP), Material: Borosilicate Glass, for TRACE GCs equipped with PTV inlets
Liner. Straight Inlet, 2.0mm ID, Length: 78.5mm, Deactivation: Intermediate Polarity (IP), Material: Borosilicate Glass
Nut Driver. Ideal for changing FID jets, Securely grips jet for easy removal or installation, 1/4-Inch
Nut. Finger-Tight Capillary Column, Allow wrench-free column installations, Work with standard (1/16inch) and compact (Agilent-style) ferrules, Made from high-quality stainless steel, pack2
Nut. Finger-Tight Capillary Column, Allow wrench-free column installations, Work with standard (1/16inch) and compact (Agilent-style) ferrules, Made from high-quality stainless steel.
Liner. Precision, Inlet, 4.0mm ID, with wool, Length: 92.1mm, OD: 6.2mm, Material: Borosilicate Glass
Adaptor, Makes setting flows easy, Meets or exceeds original manufacturer's performance.
Liner. Low Pressure Drop Inlet, 4.0mm ID, with wool, Length: 78.5mm, OD: 6.3mm, Material: Borosilicate Glass, for GCs equipped with split/splitless inlets
Liner. Inlet, Drilled Uniliner, 4.0mm ID, with Hole near Bottom, Length: 78.5mm, OD: 6.3mm, Deactivation: Intermediate Polarity (IP), Material: Borosilicate Glass
Liner. Straight Inlet, Liner ID: 1.0mm, Length: 86.2mm, OD: 4.0mm, Material: Borosilicate Glass, Deactivation: Intermediate Polarity (IP)
Regulator. ULtra-High-Purity, Material: Stainless Steel, Type: Dual-Stage, Most stable outlet pressure control.
Trap. High-Capacity Moisture, Maximumimum operating pressure: 250 psi (1, 724 kPa), Purged withuLtra-high-purity helium; ready to use.
Valve. Sulfinert Treated, Gas Sampling, 1/16inch Fittings, 0.40mm Port Diameter; 'W Type' Valve, Ideal for samples containing low concentrations of sulfur or other active compounds.
Valve. Gas Sampling, Ideal for samples containing low concentrations of sulfur or other active compounds.
Seal. Cross-Disk Inlet, ID: 0.8mm, Material: Gold-Plated, Ideal for high-flow split applications
500 mL/min on Agilent 5890 GCs.
Nut. Enhanced Capillary, eliminates the slot, increasing lifetime and durability, Meets or exceeds original manufacturer's performance.
O-Ring, Material: Viton, Maximumiumum Temperature: 250 DegreeC, for PSS Injector.
Trap. Size: 2.5 m, 0.32mm ID with 2 Press-Tight Connectors, Protects detector and valves; connects between column and detector or valve, Eliminates detector spikes and scratches in valve rotors.
Column, RT-QS-BOND, Length: 30 m, Internal Diameter: 0.32mm, DF: 10um, Separates ethane, ethylene, and acetylene to baseline.
Column, RT-MSIEVE 5A, fused silica PLOT, Length: 15 m, Internal Diameter: 0.53mm, DF: 50um, Temperature Limits: to 300 DegreeC
Column, RT-MSIEVE 5A, fused silica PLOT, Length: 30 m, Internal Diameter: 0.32mm, DF: 30um, Temperature Limits: to 300 DegreeC
Column, RT-MSIEVE 5A, fused silica PLOT, Length: 15 m, Internal Diameter: 0.53mm, DF: 50um, Temperature Limits: to 300 DegreeC
Column, RT-MSIEVE 5A, fused silica PLOT, Length: 15 m, Internal Diameter: 0.32mm, DF: 30um, Temperature Limits: to 300 DegreeC
Column, RTX-Volatile Amine, Length: 15 m, Internal Diameter: 0.32mm, Temperature Limits: -60 to 270/290 DegreeC, Unique selectivity for baseline resolution of all volatile amines.
Column, RTX-BAC Plus 1, Length: 30 m, Internal Diameter: 0.53mm, DF: 1.0um, Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences.
Column, RTX-BAC Plus 1, Length: 30 m, Internal Diameter: 0.32mm, DF: 0.6um, Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences.
Column, RTX-BAC Plus 1, Length: 30 m, Internal Diameter: 0.32mm, DF: 1.80um, Optimized column selectivities guarantee resolution of ethanol, internal standards, and frequently encountered interferences.
Column, RTX-200MS-Low-Bleed GC-MS Column, Length: 30 m, Internal Diameter: 0.32mm, DF: 1um, Temperature range: -20 DegreeC to 340 DegreeC
Column, RTX-200MS-Low-Bleed GC-MS Column, Length: 30 m, Internal Diameter: 0.25mm, DF: 1um, Temperature range: -20 DegreeC to 340 DegreeC
Column, RTX-200MS-Low-Bleed GC-MS Column, Length: 30 m, Internal Diameter: 0.25mm, DF: 0.50um, Temperature range: -20 DegreeC to 340 DegreeC
Column, RTX-200MS-Low-Bleed GC-MS Column, Length: 30 m, Internal Diameter: 0.25mm, DF: 0.25um, Temperature range: -20 DegreeC to 340 DegreeC
Column. Capillary Column,, RXI-17Sil MS, Length: 60 m, Internal Diameter: 0.25mm, DF: 0.25um, 340/360 DegreeC upper temperature limits.
Column. Capillary Column,, RXI-17Sil MS, Length: 30 m, Internal Diameter: 0.32mm, DF: 0.25um, 340/360 DegreeC upper temperature limits.
Column. Capillary Column,, RXI-17Sil MS, Length: 15 m, Internal Diameter: 0.25mm, DF: 0.25um, 340/360 DegreeC upper temperature limits.
Column. Capillary Column,, RXI-17Sil MS, Length: 20 m, Internal Diameter: 0.18mm, DF: 0.18um, 340/360 DegreeC upper temperature limits.
Column. Capillary Column,, RXI-35Sil MS, Length: 30 m, ID: 0.25mm, DF: 0.25um, Extended temperature range: 50 DegreeC to 340/360 DegreeC, Special selectivity and excellent ineRTness for substituted polar compounds, such as drugs, pesticides, herbicides, PCBs, phenols, etc
Column. Capillary Column,, RXI-35Sil MS, Length: 15 m, ID: 0.25mm, DF: 0.25um, Extended temperature range: 50 DegreeC to 340/360 DegreeC, Special selectivity and excellent ineRTness for substituted polar compounds, such as drugs, pesticides, herbicides, PCBs, phenols, etc
Column. Capillary Column,, RXI-XLB, Length: 30 m, ID: 0.25mm, DF: 1um, Temperature range: 30 DegreeC to 360 DegreeC, General-purpose Column exhibiting extremely low bleed. Ideal for many GC-MS applications, including pesticides, PCB congeners (e.g., Aroclor mixes), PAHs
Column. Capillary Column,, RXI-XLB, Length: 30 m, ID: 0.25mm, DF: 0.25um, Temperature range: 30 DegreeC to 360 DegreeC, General-purpose Column exhibiting extremely low bleed. Ideal for many GC-MS applications, including pesticides, PCB congeners (e.g., Aroclor mixes), PAHs
Column. Capillary Column, RXI-XLB, Length: 15 m, ID: 0.25mm, DF: 0.10um, Temperature range: 30 DegreeC to 360 DegreeC, General-purpose Column-ideal for GC-MS analysis of semivolatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines
Column. Capillary Column, RXI-5Sil MS, Length: 30 m, ID: 0.53mm, DF: 1.50um, Temperature range: -60 DegreeC to 350 DegreeC, General-purpose Column-ideal for GC-MS analysis of semivolatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines
Column. Capillary Column, RXI-5Sil MS, Length: 30 m, ID: 0.32mm, DF: 0.25um, Temperature range: -60 DegreeC to 350 DegreeC, General-purpose Column-ideal for GC-MS analysis of semivolatiles, polycyclic aromatic compounds, chlorinated hydrocarbons, phthalates, phenols, amines
Column. Capillary Column, RXI-17, Length: 30 m, ID: 0.53mm, DF: 1um, Temperature range: 40 DegreeC to 320 DegreeC, General-purpose Column for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, sterols.
Column. Capillary Column, RXI-17, Length: 30 m, ID: 0.25mm, DF: 0.50um, Temperature range: 40 DegreeC to 320 DegreeC, General-purpose Column for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, sterols.
Column. Capillary Column, RXI-17, Length: 30 m, ID: 0.32mm, DF: 0.25um, Temperature range: 40 DegreeC to 320 DegreeC, General-purpose Column for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, sterols.
Column. Capillary Column, RXI-17, Length: 30 m, ID: 0.25mm, DF: 0.25um, Temperature range: 40 DegreeC to 320 DegreeC, General-purpose Column for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, sterols.
Column. Capillary Column, RXI-17, Length: 15 m, ID: 0.25mm, DF: 0.25um, Temperature range: 40 DegreeC to 320 DegreeC, General-purpose Column for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, sterols.
Column. Capillary Column, RXI-17, Length: 20 m, ID: 0.18mm, DF: 0.18um, Temperature range: 40 DegreeC to 320 DegreeC, General-purpose Column for pesticides, herbicides, rosin acids, phthalate esters, triglycerides, sterols.
Column, FAMEWAX, USP G16, fused silica, Length: 30 m, Internal Diameter: 0.32mm, DF: 0.25um, Application-specific Column for FAMEs, specially tested with a FAME mixture
Column, RTX-5 Amine, fused silica, Length: 30 m, Internal Diameter: 0.25mm, DF: 0.25um, Application-specific Column for amines and other basic compounds, including alkylamines, diamines, triamines, ethanolamines, and nitrogen-containing heterocyclics.
Column, MOLESIEVE 5A, Length: 6 feet, ID: 2.1mm, OD: 1/8inch, Material: Stainless Steel Tubing, Mesh: 60/80, Molecular sieve packed Column easily separate permanent gases at above-ambient temperatures.
Column, MOLESIEVE 5A, Length: 6 feet, ID: 2.1mm, OD: 1/8inch, Material: Stainless Steel Tubing, Mesh: 80/100, Molecular sieve packed Column easily separate permanent gases at above-ambient temperatures.
Column, MOLESIEVE 5A, Length: 6 feet, ID: 2.0mm, OD: 1/8inch, Material: Stainless Steel Tubing, Mesh: 60/80, Molecular sieve packed Column easily separate permanent gases at above-ambient temperatures.
Column. Porous Polymer, Length: 6 feet, OD: 1/8inch, Material: Stainless Steel Tubing, ID: 2.1mm, 80/100 Mesh.
Column, MOLESIEVE 5A, Length: 2 m, ID: 2.0mm, OD: 1/8inch, Material: SilcoSmooth Tubing, Mesh: 60/80, Molecular sieve packed Column easily separate permanent gases at above-ambient temperatures.
Column. Capillary Column, RXI-5SIL MS, Length: 30 m, ID: 0.25mm, DF: 0.50um, Temperature range: -60 DegreeC to 330/350 DegreeC, with 10 m Integra-Guard Column
Liner. Straight Inlet, 2.0mm ID, Length: 86.2mm, OD: 4mm, Deactivation: Intermediate Polarity (IP), Material: Borosilicate Glass, for Auto SYS and Clarus GCs equipped with split/splitless inlets
Column. Capillary Column, RXI-5SIL MS, Length: 30 m, ID: 0.25mm, DF: 0.25um, Temperature range: -60 DegreeC to 330/350 DegreeC
Column, RXI Guard/Retention Gap, Nominal ID: 0.53mm, Nominal OD: 0.69 +/- 0.05mm, Length: 5 m
Column, VIVA C4, Particle Size: 5um, Length: 250mm, Internal Diameter: 4.6mm, Excellent for separating peptides or proteins.
Column, PINNACLE DB PFP Propyl, Particle Size: 5um, Length: 250mm, Internal Diameter: 4.6mm
Column, PINNACLE DB PFP Propyl, Particle Size: 5um, Length: 250mm, Internal Diameter: 2.1mm
Column, PINNACLE DB PFP Propyl, Particle Size: 5um, Length: 150mm, Internal Diameter: 4.6mm
Column, PINNACLE DB PFP Propyl, Particle Size: 5um, Length: 50mm, Internal Diameter: 2.1mm
Column, PINNACLE DB PFP Propyl, Particle Size: 5um, Length: 150mm, Internal Diameter: 2.1mm
Column, PINNACLE DB PFP Propyl, Particle Size: 5um, Length: 200mm, Internal Diameter: 4.6mm
Column, PINNACLE DB PFP Propyl, Particle Size: 5um, Length: 100mm, Internal Diameter: 4.6mm
Column, PINNACLE DB PFP Propyl, Particle Size: 5um, Length: 100mm, Internal Diameter: 2.1mm
Column, PINNACLE DB PFP Propyl, Particle Size: 3um, Length: 150mm, Internal Diameter: 2.1mm
Column, PINNACLE DB PFP Propyl, Particle Size: 3um, Length: 150mm, Internal Diameter: 4.6mm
Column, PINNACLE DB PFP Propyl, Particle Size: 3um, Length: 50mm, Internal Diameter: 4.6mm
Column, PINNACLE DB PFP Propyl, Particle Size: 3um, Length: 50mm, Internal Diameter: 2.1mm
Column, PINNACLE DB PFP Propyl, Particle Size: 3um, Length: 30mm, Internal Diameter: 2.1mm
Column. Caplillary Column, RTX-1, fused silica, Length: 20 m, Internal Diameter: 0.10mm, DF: 0.10um, Temp. Limits: -60 to 330/350 DegreeC
Column. Caplillary Column, RTX-1, fused silica, Length: 10 m, Internal Diameter: 0.10mm, DF: 0.10um, Temp. Limits: -60 to 330/350 DegreeC
Column. Caplillary Column, RTX-1, fused silica, Length: 20 m, Internal Diameter: 0.10mm, DF: 0.40um, Temp. Limits: -60 to 320/340 DegreeC
Column. Caplillary Column, RTX-1, fused silica, Length: 20 m, Internal Diameter: 0.10mm, DF: 0.10um, Temp. Limits: -60 to 330/350 DegreeC
Column. Caplillary Column, RTX-1, fused silica, Length: 10 m, Internal Diameter: 0.10mm, DF: 0.40um, Temp. Limits: -60 to 320/340 DegreeC
Column. Caplillary Column, RTX-1, fused silica, Length: 10 m, Internal Diameter: 0.10mm, DF: 0.10um, Temp. Limits: -60 to 330/350 DegreeC
Column. Caplillary Column, RTX-624, Length: 20 m, Internal Diameter: 0.18mm, DF: 1.00um, Temperature range: -20 DegreeC to 240 DegreeC.
Column. Caplillary Column, RTX-1, Length: 20 m, Internal Diameter: 0.18mm, DF: 0.40um, Temperature range: -60 to 315/330 DegreeC
Column. Caplillary Column, RTX-1, Length: 20 m, Internal Diameter: 0.18mm, DF: 0.40um, Temperature range: -60 to 330/340 DegreeC
Column. Caplillary Column, RTX-1, Length: 40 m, Internal Diameter: 0.18mm, DF: 0.40um, Temperature range: -60 to 330/340 DegreeC
Column. Caplillary Column, RTX-1, Length: 10 m, Internal Diameter: 0.18mm, DF: 0.40um, Temperature range: -60 to 315/330 DegreeC
Column. Caplillary Column, RTX-1, Length: 10 m, Internal Diameter: 0.18mm, DF: 0.40um, Temperature range: -60 to 330/340 DegreeC
Column. Caplillary Column, RTX-1, Length: 10 m, Internal Diameter: 0.18mm, DF: 0.20um, Temperature range: -60 to 330/350 DegreeC
Polywax 655, Polywax Standards, CAS number: 9002-88-4, Conc. In Solvent and Volume: Neat, 1 gram.
Standard. FID Performance Evaluation, Concentration In Solvent and Volume: 0.03 w/w% each in hexane, 1 mL/ampule
Kit, LC OQ Linearity Test Mix, Concentration In Solvent and Volume: 1 mL each of these mixtures.
PFTBA (MS Tuning Compound), Restek - 30482, 1 ml/Ampule, Perfluorotributylamine (PFTBA)
Mass Spec Cleaning Kit with Dremel Tool.
Premium Non-stick BTO Septa, Diameter: 12.7mm CenterGuide, for Tracor 220, 222 GCs, 50PACK.
Premium Non-stick BTO Septa. Diameter: 17mm CenterGuide, New plasma coating eliminates sticking in the injection port, 50PACK
Premium Non-stick BTO Septa, Diameter: 11.5mm CenterGuide, for Tracor 540 GCs, 50PACK.
Category
Ambulatory Equipment
Apparel
Appliances (Durable Goods)
Body Pressure Relief and Positioning
Clinical Laboratory
Diagnostic Instruments and Supplies
Drainage and Suction
Furnishings
Gloves
Housekeeping
Implants
Incontinence
Indicators and Signage
Instruments
IV Therapy
Needles and Syringes
Nurse's Station and Office Supplies
Nutritionals and Feeding Supplies
Orthopedic
Ostomy
other
Personal Hygiene
Pharmaceuticals
Physical Therapy
Respiratory
Services
Sterilization
Textiles
Training and Education
Urological
Utensils
Ventilators
Wound Care
Wound Closure
Prev
3
4
5
6
7
Next