logo
  • About Us
    • Retail Customer Login
    • Business User Login
    • Retail Customer Registration
    • Business User Registration
  • 0
  • Shop Products
    • Ambulatory Equipment
    • Apparel
    • Appliances (Durable Goods)
    • Body Pressure Relief and Positioning
    • Clinical Laboratory
    • Diagnostic Instruments and Supplies
    • Drainage and Suction
    • Furnishings
    • Gloves
    • Housekeeping
    • Implants
    • Incontinence
    • Indicators and Signage
    • Instruments
    • IV Therapy
    • Needles and Syringes
    • Nurse's Station and Office Supplies
    • Nutritionals and Feeding Supplies
    • Orthopedic
    • Ostomy
    • other
    • Personal Hygiene
    • Pharmaceuticals
    • Physical Therapy
    • Respiratory
    • Services
    • Sterilization
    • Textiles
    • Training and Education
    • Urological
    • Utensils
    • Ventilators
    • Wound Care
    • Wound Closure
logo
  • 0
  • Retail Customer Login
  • Business User Login
  • Retail Customer Registration
  • Business User Registration
Shop Products
  • Ambulatory Equipment
  • Apparel
  • Appliances (Durable Goods)
  • Body Pressure Relief and Positioning
  • Clinical Laboratory
  • Diagnostic Instruments and Supplies
  • Drainage and Suction
  • Furnishings
  • Gloves
  • Housekeeping
  • Implants
  • Incontinence
  • Indicators and Signage
  • Instruments
  • IV Therapy
  • Needles and Syringes
  • Nurse's Station and Office Supplies
  • Nutritionals and Feeding Supplies
  • Orthopedic
  • Ostomy
  • other
  • Personal Hygiene
  • Pharmaceuticals
  • Physical Therapy
  • Respiratory
  • Services
  • Sterilization
  • Textiles
  • Training and Education
  • Urological
  • Utensils
  • Ventilators
  • Wound Care
  • Wound Closure
$

SPEC 96-WELL ADAPTER GASKET - A596ADG

Crosslab Pursuit, XRs and XRs Ultra, Agilent Technologies - A6000250X046

Crosslab Pursuit, XRs and XRs Ultra, Agilent Technologies - A6021050X020

Crosslab Pursuit, XRs and XRs Ultra, Agilent Technologies - A6021250X046

SPEC ENVIRO DISC MANIFOLD - A712

FLASK SPEC MALE40/35MM GRND GLASS FIT 1L - A714

CARTRIDGE SPEC 47MM C18AR PK24 - A74719

OMNISPHER 5 C18 S150X4.6 COL. - CP27802

OMNISPHER 5 C18 S250X4.6 COL. - CP27803

OMNISPHER 5 C18 S250X3 - CP27812

OMNISPHER 5 C18 S150X4.6 - CP27817

OMNISPHER 5 C18 S250X4.6 - CP27819

OMNISPHER 5 C18 S100X4.6 - CP27820

CARTRIDGE OMNISPHER 5 C18 S150X3 PK3 - CP27822

CARTRIDGE OMNISPHER 5 C18 S250X4.6 PK3 - CP27823

CARTRIDGE OMNISPHER 5 C18 S100X3 PK3 - CP27824

CARTRIDGE OMNISPHER 5 C18 S150X4.6 PK3 - CP27826

OMNISPHER 5 C18 100X4.6MM - CP27833

OMNISPHER 5 C18 150X2.0MM - CP27836

OMNISPHER 3 C18 S100X3 - CP27843

CrossLab Inert Spray Chambers for ICP-OES, Agilent Technologies - G8014-68002, Inert spray chamber for 5000 series ICP-OES and MP-AES. Double pass design with removable baffle and ball joint outlet

CARTRIDGE PL-PSDA TYPE-1 (5 TO 300NM) - PL0850-1010

CARTRIDGE PL-PSDA TYPE-2 (20 TO 1200NM) - PL0850-1020

BROAD DEXTRAN 1G - PL2080-0000

SPE Columns. 100mg Sorbent, Reversed Phase Octadecyl (C18) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 1.0mL. 100/pk.

SPE Columns. 200mg Sorbent, Reversed Phase Octadecyl (C18) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 3.5mL. 50/pk.

SPE Columns. 500mg Sorbent, Reversed Phase Octadecyl (C18) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 2.5mL. 50/pk.

SPE Columns. 500mg Sorbent, Reversed Phase Octadecyl (C18) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 7.0mL. 30/pk.

SPE Columns. 1000mg Sorbent, Reversed Phase Octadecyl (C18) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 6.0mL. 30/pk.

Octadecyl (C18) SPE Column 4mL. Octadecyl (C18) SPE Column, Capacity: 4.0mL, Packaging Material: Silica, Bed Weight: 2000mg, Reservoir, retaining frit, packing material, containing frit, Alumina, Florisil, ion exchange resins, 5 or 10 column sealed internal units

SPE Columns. 100mg Sorbent, Reversed Phase Octyl (C8) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 1.0mL. 100/pk.

SPE Columns. 500mg Sorbent, Reversed Phase Octyl (C8) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 2.5mL. 50/pk.

SPE Columns. 200mg Sorbent, Reversed Phase Ethyl (C2) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 3.5mL. 50/pk.

ETHYL(C2)500MG/6ML PK30 - 9034

SILICA(SI)200MG/3500UL PK50 - 9052

SPE Columns. 500mg Sorbent, Normal Phase Silica (Si) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 2.5mL. 50/pk.

SPE Columns. 2000mg Sorbent, Normal Phase Silica (Si) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 4.0mL. 30/pk.

SPE Columns. 500mg Sorbent, Normal Phase Cyanopropyl (CN) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 2.5mL. 50/pk.

SPE Columns. 300mg Sorbent, Normal Phase Aminopropyl (NH2) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 2.8mL. 50/pk.

SPE Columns. 500mg Sorbent, Normal Phase Aminopropyl (NH2) Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 2.5mL. 50/pk.

Honeywell Burdick & Jackson Ion Exchange SPE Column, Strong Cation Exchange Sulfonated Polymer. Resin: Polystyrene Divinylbenzene, Adsorbent weight: 30mg, Column size: 1ml, Particle size: 20-60u, Pore size: 100A, Capacity: approx. 1.8meq/g, Surface area: 200m2/g, 100ea per pack.

Honeywell Burdick & Jackson Ion Exchange SPE Column, Strong Cation Exchange Sulfonated Polymer. Resin: Polystyrene Divinylbenzene, Adsorbent weight: 50mg, Column size: 3ml, Particle size: 20-60u, Pore size: 100A, Capacity: approx. 1.8meq/g, Surface area: 200m2/g, 50ea per pack.

Column. Ion Exchange SPE Column, Strong Anion Exchange Quaternary Amine bonded Polymer, Resin: Polystyrene Divinylbenzene, Adsorbent weight: 30mg, Column size: 1ml, Particle size: 20-30u, Pore size: 100A, Capacity: approx. 2.1meq/g, Surface area: 200m2/g, 100ea per pack

Column. Ion Exchange SPE Column, Strong Cation Exchange (Silica Based) Benzenesulfonic Acid, Adsorbent weight: 100mg, Column size: 1ml, Particle size: 40-63u, Pore size: 55-75A, Capacity: 0.307-0.341meq/g, Surface area: 470-530m2/g, %Carbon: 9.28-12.10, 100ea per pack.

Column. Ion Exchange SPE Column, Strong Cation Exchange (Silica Based) Benzenesulfonic Acid, Adsorbent weight: 200mg, Column size: 3ml, Particle size: 40-63u, Pore size: 55-75A, Capacity: 0.307-0.341meq/g, Surface area: 470-530m2/g, %Carbon: 9.28-12.10, 50ea per pack

Column. Ion Exchange SPE Column, Strong Cation Exchange (Silica Based) Benzenesulfonic Acid, Adsorbent weight: 500mg, Column size: 6ml, Particle size: 40-63u, Pore size: 55-75A, Capacity: 0.307-0.341meq/g, Surface area: 470-530m2/g, %Carbon: 9.28-12.10, 30ea per pack

Column. Ion Exchange SPE Column, Strong Anion Exchange (Silica Based) Quaternary Amine bonded, Adsorbent weight: 100mg, Column size: 1ml, Particle size: 40-63u, Pore size: 55-75A, Capacity: 0.200-0.260meq/g, Surface area: 470-530m2/g, %Carbon: 7.09-9.71, 100ea per pack

Column. Ion Exchange SPE Column, Strong Anion Exchange (Silica Based) Quaternary Amine bonded, Adsorbent weight: 200mg, Column size: 3ml, Particle size: 40-63u, Pore size: 55-75A, Capacity: 0.2000.260meq/g, Surface area: 470-530m2/g, %Carbon: 7.09-9.71, 50ea per pack

Column. Ion Exchange SPE Column, Strong Anion Exchange (Silica Based) Quaternary Amine bonded, Adsorbent weight: 500mg, Column size: 6ml, Particle size: 40-63u, Pore size: 55-75A, Capacity: 0.200-0.260meq/g, Surface area: 470-530m2/g, %Carbon: 7.09-9.71, 30ea per pack

SPE Columns. 200mg Sorbent, Adsorption Florisil Columns. Reservoir, retaining frit, packing material, containing frit. Alumina, Florisil, ion exchange resins available. Attach to vacuum manifold through Luer-tip exit port. 5 or 10 column sealed internal units. Capacity 3.5mL. 50/pk.

Honeywell Burdick & Jackson Florisil-PR SPE Columns are used for sample preparation. Adsorbent weight is 1000mg per column. Column size: 15ml Particle size: 60/100 Mesh (150-250u) 100ea per pack.

ALUMIN(ACIDIC)1000MG/2.8MLPK30 - 9128

ALUMINA(NEUTRAL)100MG/1MLPK100 - 9130

ALUMINA(NEUTRAL)1000MG/6MLPK30 - 9138

OCTADECYL (C18) 300MG PK25 - 9200

OCTADECYL (C18) 600MG PK25 - 9202

SPE Columns, Honeywell Burdick - 9204, Octadecyl (C18)

OCTYL (C8) 300MG PK25 - 9210

OCTYL (C8) 600MG PK25 - 9212

OCTYL (C8) 900MG PK25 - 9214

ETHYL (C2) 300MG PK25 - 9220

SILICA (SI) 300MG PK25 - 9230

SILICA (SI) 600MG PK25 - 9232

SILICA (SI) 900MG PK25 - 9234

FLORISIL 300MG PK25 - 9260

MANIFOLD VACUUM 16-PORT - 9300

Solid Phase Extraction 24-Port Vacuum Manifold.

GLASS BLOCK 16-PORT - 9302

GLASS BLOCK 24-PORT - 9303

ALUMINA (NEUT) CART 900MG PK25 - 9304

MANIFOLD LID 24-PORT - 9305

MANIFOLD LID 16-PORT - 9306

GUAGE & VALVE VACUUM ASSEM - 9311

LUER TIPS TEFLON PK12 - 9312

LUER FITTINGS BULKHEAD PK12 - 9314

LEGS FOR MANIFOLD LID PK4 - 9315

STOPCOCKS PK12 - 9316

STOPCOCKS PK16 - 9317

STOPCOCKS PK24 - 9318

LUER PLUGS PK12 - 9319

TRAY SAFETY FOR VAC MANIFOLD - 9320

Clean Thru Tip for Solid Phase Extraction Vacuum Manifold.

ADAPTER FOR SPE COLUMN PK15 - 9322

RESERVOIR 75ML(NO FRITS)PK100 - 9434

RESERVOIR 1.5ML(NO FRITS)PK100 - 9436

RESERVOIR W/100 FRITS 4ML PK50 - 9438

RESERVOIR W/100FRITS PK50 8ML - 9440

RESERVOIR W/200FRITSPK100 75ML - 9442

FRIT FITS 75ML PK100 - 9444

Column Filters and Frits for SPE Columns, Burdick and Jackson® - 9448, Filter Column with 2 frits/column, Inserted

FILTER COL 8.0 ML(2 FRITS)PK50 - 9450

FRIT:FITS 1500UL RES PK100 - 9452

FRIT:FITS 4.0 ML RES PK100 - 9454

FRIT:FITS 8.0 ML RES PK100 - 9456

FRITS FOR 25ML SPE CLMN 10K/PK - 9458

Column. Drug Abuse SPE Columns are suitable for sample preparation in testing for drugs of abuse, Adsorbent weight is 200mg per column. Column size: 3ml Particle size: 40-63u Pore size: 55-75A Surface area: 470-530 m2/g %Carbon: 12.0-12.8 50 columns per pack

Column. Drug Abuse SPE Columns are suitable for sample preparation in testing for drugs of abuse, Adsorbent weight is 500mg per column. Column size: 3ml Particle size: 40-63u Pore size: 55-75A Surface area: 470-530 m2/g %Carbon: 12.0-12.8 50 columns per pack

Column. Drug Abuse SPE Columns are suitable for sample preparation in testing for drugs of abuse, Adsorbent weight is 500mg per column. Column size: 6ml Particle size: 40-63u Pore size: 55-75A Surface area: 470-530 m2/g %Carbon: 12.0-12.8 30 columns per pack

Column. Drug Abuse SPE Columns are suitable for sample preparation in testing for drugs of abuse, Adsorbent weight is 1000mg per column. Column size: 6ml Particle size: 40-63u Pore size: 55-75A Surface area: 470-530 m2/g %Carbon: 12.0-12.8 30 columns per pack

Column. THC SPE Columns are suitable for sample preparation in testing for marijuana use, Adsorbent weight is 130mg per column. Column size: 1ml 100 columns per pack

Category
  • Prev
  • 28
  • 29
  • 30
  • 31
  • Next

We search our sources worldwide for the best values in medical products and select the best values. We offer them here so you can shop in confidence.

Useful Links

  • Support

Help

  • Home
  • About Us
  • Contact Us

Policy

  • Privacy policy
  • Terms and Conditions
  • Return Policy
  • Refund Policy

Copyright® 2016 - 2025 RELIANCE INC | All rights reserved.

Icon