logo
  • About Us
    • Retail Customer Login
    • Business User Login
    • Retail Customer Registration
    • Business User Registration
  • 0
  • Shop Products
    • Ambulatory Equipment
    • Apparel
    • Appliances (Durable Goods)
    • Body Pressure Relief and Positioning
    • Clinical Laboratory
    • Diagnostic Instruments and Supplies
    • Drainage and Suction
    • Furnishings
    • Gloves
    • Housekeeping
    • Implants
    • Incontinence
    • Indicators and Signage
    • Instruments
    • IV Therapy
    • Needles and Syringes
    • Nurse's Station and Office Supplies
    • Nutritionals and Feeding Supplies
    • Orthopedic
    • Ostomy
    • other
    • Personal Hygiene
    • Pharmaceuticals
    • Physical Therapy
    • Respiratory
    • Services
    • Sterilization
    • Textiles
    • Training and Education
    • Urological
    • Utensils
    • Ventilators
    • Wound Care
    • Wound Closure
logo
  • 0
  • Retail Customer Login
  • Business User Login
  • Retail Customer Registration
  • Business User Registration
Shop Products
  • Ambulatory Equipment
  • Apparel
  • Appliances (Durable Goods)
  • Body Pressure Relief and Positioning
  • Clinical Laboratory
  • Diagnostic Instruments and Supplies
  • Drainage and Suction
  • Furnishings
  • Gloves
  • Housekeeping
  • Implants
  • Incontinence
  • Indicators and Signage
  • Instruments
  • IV Therapy
  • Needles and Syringes
  • Nurse's Station and Office Supplies
  • Nutritionals and Feeding Supplies
  • Orthopedic
  • Ostomy
  • other
  • Personal Hygiene
  • Pharmaceuticals
  • Physical Therapy
  • Respiratory
  • Services
  • Sterilization
  • Textiles
  • Training and Education
  • Urological
  • Utensils
  • Ventilators
  • Wound Care
  • Wound Closure
$

Tubes Color Comparison Nessler APHA Standard with Cap Stopper (Matched Set of 6). Grad. at (mL); 50. Approx. O.D. (mm); 20. Approx. Height Including Stopper (mm); 312. Scale Length (mm); 200-220. [standard taper] Joint; 19/10.

Wintrobe Sedimentation Rate Tubes and Racks, KIMBLE CHASE®, DWK Life Sciences - 64FR828B-BLUE, Wintrobe erythrocyte sedimentation rate (ESR) tubes, with round bottom, calibration in blue, fill with 9 IN. Pasteur pipet

KIMAX® Nessler Color Comparison Tubes, Tall Form, APHA Standard, Kimble Chase - 45315A-50100, Matched Set

Pipets Micro Capillary Disposable To Contain. Microliter (Lambda); 20. Tol (%); 0.5. Color Code; Black Calibrated to contain. Pipets are 5 inches long with a single black capacity ring and are color-coded for selection of the correct size. Clean and ready to use.

Pipets Micro Capillary Disposable To Contain. Microliter (Lambda); 25. Tol (%); 0.5. Color Code; 2 White Calibrated to contain. Pipets are 5 inches long with a single black capacity ring and are color-coded for selection of the correct size. Clean and ready to use.

Tubes Culture Disposable Screw-Cap Finish Round Bottom. Approx. O.D. (mm); 20. Approx. Length (mm); 150. Approx. Overflow Capacity (mL); 30. GPI Thread Finish; 18-415 Tubes are suitable for tissue culture work and general bacteriological use. Without a marking area.

Distillation head 250mm condenser. Distillation head, 250mm effective condenser length, 24/40 bottom & sidearm, 14/20 thermometer joint, no 11 Ace-Thred inlet/outlet

Distillation head short-path 24/40. Distillation head, short-path, with an integral 180mm long vacuum jacketed vigreux column, column features 24/40, 14/20 thermometer joint, No 11 Ace-Thred 100mm condenser inlet/outlet, Ace-Thred No 7 vacuum monitor po

Distribution receiver short path still 24/40 condenser. Distribution receiver, short path still, 24/40 condenser connection joint and (3) 24/40 drip tip receiving flask joints, No 11 Ace-Thred vacuum port

Microwave Extraction Tubes, 33 expansion borosilicate, round bottom, unmarked, 30 mm x 200 mm.

Distillation head, short-path, 24/40,14/20 thermometer joint, 220mm vigreux column, no.11 Ace-Thred and trade 150mm condenser inlet/outlet, no.7 vacuum monitor port, drip tip, and also with integral vigreux vapor path column

Short-Path Support Package 2000/5000Ml. Short-path distillation system matched support package, For 2000 & 5000mL 6815 family glassware, heating & stirring packages, For applications such as cannabinoid distillation, Modular in design to accommodate the well-equipped lab with complete turnkey system

Shortpath Distillation System Trap Pack. Short-path distillation system, 2000-5000mL vacuum cold trap package, optional, For applications cannabinoid distillation, Modular in design to accommodate the well-equipped lab as well as those needing complete turnkey systems including a vacuum cold trap

Short-Path Distillation Tubing Package. Short-path distillation system tubing package, With two sizes of FEP (Fluorinated Ethylene Propylene) tubing, 3/8in ID x 7/16in OD (10 feet) & 3/8in ID x 1/2in OD (10 feet), For cannabinoid distillation, Modular in design to accommodate the well-equipped lab

Short-Path Distillation Support Package. Short-path distillation system matched support package, Supports our 12000mL 6815-120 glassware, heating & stirring package, For cannabinoid distillation, Modular in design to accommodate the well-equipped lab as well as those needing complete turnkey systems

Short-Path Distillation System 12000Ml. Short-path distillation system, 12000mL vacuum cold trap package, optional, For cannabinoid distillation, Packages are modular in design to accommodate the well-equipped lab as well as those needing complete turnkey systems including a vacuum cold trap

Short-Path Distillation System 2000 Ml. Short-path distillation system, 2000mL, glassware, heating, stirring equipment package, For cannabinoid distillation, Modular in design to accommodate the well-equipped lab as well as those needing complete turnkey systems including vaccum cold trap

Short-Path Distillation System 5000 Ml. Short-path distillation system, 5000mL, glassware, heating, stirring equipment package, For cannabinoid distillation, Modular in design to accommodate the well-equipped lab as well as those needing complete turnkey systems including vaccum cold trap

Filtering Bottle, United Scientific Supplies - FFB5340-20000, 20000 ml

Winterization Kits, United Scientific Supplies - WNTK5, 5000 ml, Winterization labware kit

Winterization Kits, United Scientific Supplies - WNTK10, 10000 ml, Winterization labware kit

Short Path Distillation Kits, United Scientific Supplies - SPDK01, 250 ml, Complete small scale shortpath kit

Short Path Distillation Kits, United Scientific Supplies - SPD102, 10000 ml, Complete large scale shortpath kit

Distillation Condenser, Ace Glass - 6603-02, Distillation condenser

Distillation Condenser, Ace Glass - 6603-04, Distillation condenser

Distillation Condenser, Ace Glass - 6603-06, Distillation condenser

SOLVENT DISTILLATION HEAD, AIRFREE. Solvent Still Head, 125ml. Still head in 125 or 500ml capacity for use in re-purification of solvents under inert atmosphere. One piece design of condenser and storage reservoir eliminates multiple connections usually associated with distillation setup.

SOLVENT DISTILLATION HEAD, AIRFREE. Solvent Still Head, 500ml. Still head in 125 or 500ml capacity for use in re-purification of solvents under inert atmosphere. One piece design of condenser and storage reservoir eliminates multiple connections usually associated with distillation setup.

HICKMAN STILL HEAD, MINUM-WARE. Unique design of the Hickman still makes it both the collection vessel and condenser for simple fractional distillations. The threaded side port permits easy removal of distillate via a syringe or Pasteur pipette. Side port has a 8-425 thread.

DISTILLING COLUMN, VIGREUX, MINUM-WARE. Column Height: 75; Overall Length: 125. Vigreux style column with indentations for improved vapor-liquid contact. Column height is the length of the indented section. Upper threaded outer joint and lower inner joint are 14/10.

DISTILLING COLUMN, VIGREUX, MINUM-WARE. Column Height: 100; Overall Length: 145. Vigreux style column with indentations for improved vapor-liquid contact. Column height is the length of the indented section. Upper threaded outer joint and lower inner joint are 14/10.

ADAPTER, FLUSHING, AIRFREE. Joint size: 24/40. Glass stopcock. Allows vessels to be flushed with inert gas while sampling directly thru bore of 'T'-bore stopcock. Available with a 4mm glass stopcock having a constant pressure retention device or 4mm bore 1-5 taper fluoropolymer resin plug. The 9x1.

ADAPTER, VACUUM TAKE-OFF, 105[degree]. HxW: 145x105mm. Joint size: 24/40. With standard taper top outer and lower inner joints with sealed in drip tip. Adapter is bent at a 105[degree] angle for use in vacuum distillation. Serrated hose connection has an O.D.

DISTILLING BULB, KUGELROHR. Bulb: 10ml. Bulb Diameter: 30mm; Bulb Height: 85mm. Kugelrohr bulbs having 14/20 standard taper joints on both ends to connect to other bulbs or single neck round bottom flasks. CG-1012-14 adapter permits connection Kugelrohr assembly to vacuum.

DISTILLING BULB, KUGELROHR. Bulb: 15ml. Bulb Diameter: 35mm; Bulb Height: 90mm. Kugelrohr bulbs having 14/20 standard taper joints on both ends to connect to other bulbs or single neck round bottom flasks. CG-1012-14 adapter permits connection Kugelrohr assembly to vacuum.

DISTILLING BULB, KUGELROHR. Bulb: 25ml. Bulb Diameter: 40mm; Bulb Height: 98mm. Kugelrohr bulbs having 14/20 standard taper joints on both ends to connect to other bulbs or single neck round bottom flasks. CG-1012-14 adapter permits connection Kugelrohr assembly to vacuum.

DISTILLING BULB, KUGELROHR. Bulb: 50ml. Bulb Diameter: 50mm; Bulb Height: 105mm. Kugelrohr bulbs having 14/20 standard taper joints on both ends to connect to other bulbs or single neck round bottom flasks. CG-1012-14 adapter permits connection Kugelrohr assembly to vacuum.

DISTILLING HEAD, SOLVENT, MODIFIED. 250ml. Joint size: Take-off Joint: 24/40. Designed to maintain distilled solvents in an inert atmosphere. Top of main vapor tube is open and an additional vapor tube has been added to decrease risk of pressure buildup.

DISTILLING HEAD, SOLVENT, MODIFIED. 250ml. Joint size: Take-off Joint: 14/20. Designed to maintain distilled solvents in an inert atmosphere. Top of main vapor tube is open and an additional vapor tube has been added to decrease risk of pressure buildup.

DISTILLING HEAD, SOLVENT, MODIFIED. 500ml. Joint size: Take-off Joint: 24/40. Designed to maintain distilled solvents in an inert atmosphere. Top of main vapor tube is open and an additional vapor tube has been added to decrease risk of pressure buildup.

DISTILLING HEAD, SOLVENT, MODIFIED. 1000ml. Joint size: Take-off Joint: 24/40. Designed to maintain distilled solvents in an inert atmosphere. Top of main vapor tube is open and an additional vapor tube has been added to decrease risk of pressure buildup.

DISTILLING HEAD. HxW: 105x210mm. Joint size: 14/20. Condenser Length: 110mm. Simple distillation head with a condenser sealed to the adapter at a 75[degree] angle. The top outer joint on the 14/20 size can be converted to a 10/18 thermometer joint by using a CG-1016-27 bushing adapter.

DISTILLING HEAD. HxW: 165x420mm. Joint size: 24/40. Condenser Length: 250mm. Simple distillation head with a condenser sealed to the adapter at a 75[degree] angle. The top outer joint on the 14/20 size can be converted to a 10/18 thermometer joint by using a CG-1016-27 bushing adapter.

DISTILLING HEAD, SHORT PATH. Without Vigreux Indentations. WxH: 110x115. Joint size: Lower Inner: 14/20; Top Thermometer Joint: 10/18. Designed for use with small quantities where hold up between the flask and receiver must be kept to a minimum. The thermometer bulb and stem serve as column packing.

DISTILLING HEAD, SHORT PATH. Without Vigreux Indentations. WxH: 195x160. Joint size: Lower Inner: 24/40; Top Thermometer Joint: 10/30. Designed for use with small quantities where hold up between the flask and receiver must be kept to a minimum. The thermometer bulb and stem serve as column packing.

DISTILLING HEAD, SHORT PATH. Without Vigreux Indentations. WxH: 195x150. Joint size: Lower Inner: 24/40; Top Thermometer Joint: 14/20. Designed for use with small quantities where hold up between the flask and receiver must be kept to a minimum. The thermometer bulb and stem serve as column packing.

DISTILLING HEAD, SHORT PATH. With Vigreux Indentations. WxH: 110x110. Joint size: Lower Inner: 14/20; Top Thermometer Joint: 10/18. Designed for use with small quantities where hold up between the flask and receiver must be kept to a minimum. The thermometer bulb and stem serve as column packing.

DISTILLING HEAD, SHORT PATH. With Vigreux Indentations. WxH: 195x160. Joint size: Lower Inner: 24/40; Top Thermometer Joint: 10/30. Designed for use with small quantities where hold up between the flask and receiver must be kept to a minimum. The thermometer bulb and stem serve as column packing.

DISTILLING HEAD, SHORT PATH. With Vigreux Indentations. WxH: 195x150. Joint size: Lower Inner: 24/40; Top Thermometer Joint: 14/20. Designed for use with small quantities where hold up between the flask and receiver must be kept to a minimum. The thermometer bulb and stem serve as column packing.

DISTILLING HEAD, SHORT PATH, IMPROVED. Without Vigreux Indentations. WxH: 195x160mm. Joint size: Lower Inner: 24/40; Top Thermometer Joint: 10/30. Similar to CG-1239, but with the condenser being a combination of a cold coil and Leibig.

DISTILLING HEAD, SHORT PATH, IMPROVED. With Vigreux Indentations. WxH: 195x160mm. Joint size: Lower Inner: 24/40; Top Thermometer Joint: 10/30. Similar to CG-1239, but with the condenser being a combination of a cold coil and Leibig.

DISTILLING HEAD, SHORT PATH, JACKETED. Without Vigreux Indentations. WxH: 105x105. Joint size: Lower Inner: 14/20; Top Thermometer Joint: 10/18. Similar to CG-1239 but vacuum jacketed to improve efficiency.

DISTILLING HEAD, SHORT PATH, JACKETED. Without Vigreux Indentations. WxH: 200x150. Joint size: Lower Inner: 24/40; Top Thermometer Joint: 10/30. Similar to CG-1239 but vacuum jacketed to improve efficiency.

DISTILLING HEAD, SHORT PATH, JACKETED. Without Vigreux Indentations. WxH: 200x150. Joint size: Lower Inner: 24/40; Top Thermometer Joint: 14/20. Similar to CG-1239 but vacuum jacketed to improve efficiency.

DISTILLING HEAD, SHORT PATH, JACKETED. With Vigreux Indentations. WxH: 105x105. Joint size: Lower Inner: 14/20; Top Thermometer Joint: 10/18. Similar to CG-1239 but vacuum jacketed to improve efficiency.

DISTILLING HEAD, SHORT PATH, JACKETED. With Vigreux Indentations. WxH: 200x150. Joint size: Lower Inner: 24/40; Top Thermometer Joint: 10/30. Similar to CG-1239 but vacuum jacketed to improve efficiency.

DISTILLING HEAD, SHORT PATH, JACKETED. With Vigreux Indentations. WxH: 200x150. Joint size: Lower Inner: 24/40; Top Thermometer Joint: 14/20. Similar to CG-1239 but vacuum jacketed to improve efficiency.

DISTILLATION HEAD, VIGREUX, MICRO. HxW: 195x185mm. Joint size: 14/20. Distillation head with condenser sealed to a Vigreux column. Top thermometer joint is a 10/18 for use with a 1in. immersion thermometer. Vacuum adapter has an outer joint and accepts a CG-1279-11 distribution adapter.

DISTILLATION HEAD, JACKETED, VIGREUX, MICRO. HxW: 195x190mm. Joint size: 14/20. Similar to CG-1241 but with the Vigreux column vacuum jacketed to improve distillation performance.

DISTILLATION HEAD, VIGREUX, JACKETED. HxW: 200x180mm. Joint size: 14/20. Column Height: 100mm; Thermometer: 10/18. Vacuum jacketed Vigreux distillation head having a sealed on condenser, braced for strength. The top outer joint is for a 1in. immersion 10/18 or 10/30 thermometer.

DISTILLATION HEAD, VIGREUX, JACKETED. HxW: 325x350mm. Joint size: 24/40. Column Height: 200mm; Thermometer: 10/30. Vacuum jacketed Vigreux distillation head having a sealed on condenser, braced for strength. The top outer joint is for a 1in. immersion 10/18 or 10/30 thermometer.

DISTILLATION HEAD, VIGREUX, JACKETED. HxW: 425x350mm. Joint size: 24/40. Column Height: 300mm; Thermometer: 10/30. Vacuum jacketed Vigreux distillation head having a sealed on condenser, braced for strength. The top outer joint is for a 1in. immersion 10/18 or 10/30 thermometer.

DISTILLING HEAD, VIGREUX, VACUUM JACKETED. Glass Stopcocks. HxW: 255x310mm. Joint size: 14/20. Thermometer Joints: 10/18. Jacketed fractionation distilling head for use under vacuum. The 10/18 top outer joint is for a 1in. immersion thermometer while the 10/30 joints are for a 2in.

DISTILLING HEAD, VIGREUX, VACUUM JACKETED. Glass Stopcocks. HxW: 550x325mm. Joint size: 24/40. Thermometer Joints: 10/30. Jacketed fractionation distilling head for use under vacuum. The 10/18 top outer joint is for a 1in. immersion thermometer while the 10/30 joints are for a 2in.

DISTILLING HEAD, VIGREUX, VACUUM JACKETED. fluoropolymer resin Stopcocks. HxW: 255x310mm. Joint size: 14/20. Thermometer Joints: 10/18. Jacketed fractionation distilling head for use under vacuum. The 10/18 top outer joint is for a 1in. immersion thermometer while the 10/30 joints are for a 2in.

DISTILLING HEAD, VIGREUX, VACUUM JACKETED. fluoropolymer resin Stopcocks. HxW: 550x325mm. Joint size: 24/40. Thermometer Joints: 10/30. Jacketed fractionation distilling head for use under vacuum. The 10/18 top outer joint is for a 1in. immersion thermometer while the 10/30 joints are for a 2in.

DISTILLING RECEIVER, MOISTURE TEST, BIDWELL-STERLING. 5ml. HxW: 275x90mm. Joint size: 24/40. Bidwell-Sterling type receiver used to determine the moisture in foods and organics. Made to ASTM specification E123. Also conforms with many methods of American oil Chemists Society.

DISTILLING RECEIVER, MOISTURE TEST, DEAN-STARK. 10ml. HxW: 250x90mm. Joint size: 24/40. Dean-Stark receiver used for determining the water content of various materials. Can be used with ASTM Method D-95 along with similar ASTM methods. The 10ml size has subdivisions of 0.1 from 0 to 2ml, and 0.

DISTILLING RECEIVER, MOISTURE TEST, DEAN-STARK. 25ml. HxW: 330x90mm. Joint size: 24/40. Dean-Stark receiver used for determining the water content of various materials. Can be used with ASTM Method D-95 along with similar ASTM methods. The 10ml size has subdivisions of 0.1 from 0 to 2ml, and 0.

DISTILLING RECEIVER, MOISTURE TEST, DEAN-STARK. 10ml. HxW: 225x80mm. Joint size: 14/20. Dean-Stark receiver used for determining the water content of various materials. Can be used with ASTM Method D-95 along with similar ASTM methods. The 10ml size has subdivisions of 0.1 from 0 to 2ml, and 0.

DISTILLING RECEIVER, MOISTURE TEST, DEAN-STARK. 25ml. HxW: 300x80mm. Joint size: 14/20. Dean-Stark receiver used for determining the water content of various materials. Can be used with ASTM Method D-95 along with similar ASTM methods. The 10ml size has subdivisions of 0.1 from 0 to 2ml, and 0.

DISTILLING RECEIVER, MOISTURE TEST, DEAN-STARK. 10ml. HxW: 220x80mm. Joint size: 14/20. Similar to CG-1258 but with the addition of an overflow tube between the uptake tube and the graduated receiver.

DISTILLING RECEIVER, MOISTURE TEST, DEAN-STARK. 10ml. HxW: 250x90mm. Joint size: 24/40. Similar to CG-1258 but with the addition of an overflow tube between the uptake tube and the graduated receiver.

DISTILLING RECEIVER, MOISTURE TEST, DEAN-STARK. 25ml. HxW: 330x95mm. Joint size: 24/40. Similar to CG-1258 but with the addition of an overflow tube between the uptake tube and the graduated receiver.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. Glass Stopcock. 10ml. HxW: 190x65mm. Joint size: 14/20. Barrett style distilling receiver used to determine the water content in petroleum or bituminous material.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. Glass Stopcock. 10ml. HxW: 275x95mm. Joint size: 24/40. Barrett style distilling receiver used to determine the water content in petroleum or bituminous material.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. Glass Stopcock. 20ml. HxW: 325x95mm. Joint size: 24/40. Barrett style distilling receiver used to determine the water content in petroleum or bituminous material.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. fluoropolymer resin Stopcock. 2ml. HxW: 225x65mm. Joint size: 14/20. Barrett style distilling receiver used to determine the water content in petroleum or bituminous material.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. fluoropolymer resin Stopcock. 5ml. HxW: 205x65mm. Joint size: 14/20. Barrett style distilling receiver used to determine the water content in petroleum or bituminous material.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. fluoropolymer resin Stopcock. 10ml. HxW: 190x65mm. Joint size: 14/20. Barrett style distilling receiver used to determine the water content in petroleum or bituminous material.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. fluoropolymer resin Stopcock. 10ml. HxW: 190x75mm. Joint size: 19/22. Barrett style distilling receiver used to determine the water content in petroleum or bituminous material.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. fluoropolymer resin Stopcock. 10ml. HxW: 275x95mm. Joint size: 24/40. Barrett style distilling receiver used to determine the water content in petroleum or bituminous material.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. fluoropolymer resin Stopcock. 20ml. HxW: 325x95mm. Joint size: 24/40. Barrett style distilling receiver used to determine the water content in petroleum or bituminous material.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT, VACUUM JACKETED. fluoropolymer resin Stopcock. 5ml. HxW: 205x75mm. Joint size: 14/20. Similar to CG-1261, but with the uptake tube vacuum jacketed to improve distillation performance.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT, VACUUM JACKETED. fluoropolymer resin Stopcock. 10ml. HxW: 190x75mm. Joint size: 14/20. Similar to CG-1261, but with the uptake tube vacuum jacketed to improve distillation performance.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT, VACUUM JACKETED. fluoropolymer resin Stopcock. 10ml. HxW: 275x105mm. Joint size: 24/40. Similar to CG-1261, but with the uptake tube vacuum jacketed to improve distillation performance.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT, VACUUM JACKETED. fluoropolymer resin Stopcock. 20ml. HxW: 325x105mm. Joint size: 24/40. Similar to CG-1261, but with the uptake tube vacuum jacketed to improve distillation performance.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. Glass Stopcock. 10ml. HxW: 275x95mm. Joint size: 24/40. Similar to CG-1261 but with the addition of an overflow tube between the uptake tube and the graduated receiver.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. Glass Stopcock. 20ml. HxW: 325x95mm. Joint size: 24/40. Similar to CG-1261 but with the addition of an overflow tube between the uptake tube and the graduated receiver.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. fluoropolymer resin Stopcock. 10ml. HxW: 275x95mm. Joint size: 24/40. Similar to CG-1261 but with the addition of an overflow tube between the uptake tube and the graduated receiver.

DISTILLING RECEIVER, MOISTURE TEST, BARRETT. fluoropolymer resin Stopcock. 20ml. HxW: 325x95mm. Joint size: 24/40. Similar to CG-1261 but with the addition of an overflow tube between the uptake tube and the graduated receiver.

DISTILLING RECEIVER, MOISTURE TEST, MERLIC. fluoropolymer resin Stopcock. 10ml. HxW: 275x75mm. Joint size: 14/20. Modified Dean Stark trap allows for more efficient cooling and separation of the azeotrope during distillation. Graduated from 0 to 10ml in 0.1ml subdivisions.

DISTILLING RECEIVER, MOISTURE TEST, MERLIC. fluoropolymer resin Stopcock. 10ml. HxW: 290x105mm. Joint size: 24/40. Modified Dean Stark trap allows for more efficient cooling and separation of the azeotrope during distillation. Graduated from 0 to 10ml in 0.1ml subdivisions.

DISTILLING RECEIVER, DEAN STARK, MODIFIED. HxW: 355x240mm. Joint size: 24/40. This innovative and compact Dean-Stark receiver is designed for azeotropic distillations using solvents that are heavier than water.

DISTILLATION RECEIVER, SOLVENT RECOVERY, GRADUATED. 250ml. HxW: 415x185mm. Joint size: 24/40. Subdivisions: 5.0ml. Graduated distillation receiver with a 4mm three way stopcock to permit solvent removal through the 10mm O.D. tube or return to distillation flask.

DISTILLATION RECEIVER, SOLVENT RECOVERY, GRADUATED. 500ml. HxW: 465x230mm. Joint size: 24/40. Subdivisions: 5.0ml. Graduated distillation receiver with a 4mm three way stopcock to permit solvent removal through the 10mm O.D. tube or return to distillation flask.

DISTILLING RECEIVER. Complete Receiver. 12ml. HxW: 175X240mm. Joint size: 14/20. The 135[degree] angle between the center line of the condenser and the receiver tubes allow the distillate to fall directly into the receiver tubes. This receiver can be used with short path style distilling heads.

DISTILLING RECEIVER. Replacement Components. Distribution Adapter, 14/20. The 135[degree] angle between the center line of the condenser and the receiver tubes allow the distillate to fall directly into the receiver tubes. This receiver can be used with short path style distilling heads.

Category
  • Prev
  • 2
  • 3
  • 4
  • 5
  • 6
  • Next

We search our sources worldwide for the best values in medical products and select the best values. We offer them here so you can shop in confidence.

Useful Links

  • Support

Help

  • Home
  • About Us
  • Contact Us

Policy

  • Privacy policy
  • Terms and Conditions
  • Return Policy
  • Refund Policy

Copyright® 2016 - 2025 RELIANCE INC | All rights reserved.

Icon