About Us
Login
Retail Customer Login
Business User Login
Registration
Retail Customer Registration
Business User Registration
0
Shop Products
Ambulatory Equipment
Apparel
Appliances (Durable Goods)
Body Pressure Relief and Positioning
Clinical Laboratory
Diagnostic Instruments and Supplies
Drainage and Suction
Furnishings
Gloves
Housekeeping
Implants
Incontinence
Indicators and Signage
Instruments
IV Therapy
Needles and Syringes
Nurse's Station and Office Supplies
Nutritionals and Feeding Supplies
Orthopedic
Ostomy
other
Personal Hygiene
Pharmaceuticals
Physical Therapy
Respiratory
Services
Sterilization
Textiles
Training and Education
Urological
Utensils
Ventilators
Wound Care
Wound Closure
0
Retail Customer Login
Business User Login
Retail Customer Registration
Business User Registration
Shop Products
Ambulatory Equipment
Apparel
Appliances (Durable Goods)
Body Pressure Relief and Positioning
Clinical Laboratory
Diagnostic Instruments and Supplies
Drainage and Suction
Furnishings
Gloves
Housekeeping
Implants
Incontinence
Indicators and Signage
Instruments
IV Therapy
Needles and Syringes
Nurse's Station and Office Supplies
Nutritionals and Feeding Supplies
Orthopedic
Ostomy
other
Personal Hygiene
Pharmaceuticals
Physical Therapy
Respiratory
Services
Sterilization
Textiles
Training and Education
Urological
Utensils
Ventilators
Wound Care
Wound Closure
$
Go Back
Rt-Msieve 5A Column 50um. Rt-Msieve 5A Column, fused silica PLOT, Length: 15m, ID: 0.25mm, Df: 20um, Easily separate permanent gases at temperatures above ambient. PLOT technology reduces particle release, improving flow reproducibility and reducing downtime for maintenance. Stable to 300 deg C.
Rt-S-BOND Column 10um. Rt-S-BOND Column, fused silica PLOT, Length: 30m, 0.32mm ID, Df: 10um, Midpolarity porous polymer PLOT column, incorporating high 4-vinylpyridine. Use for the analysis of nonpolar and polar compounds. Stable to 250 deg C. Similar Phase(s): CP-PoraPLOT S
Rt-U-BOND Column 10um. Rt-U-BOND Column, fused silica PLOT, Length: 15M, ID: 0.32mm, Df: 10um, No Cage, No Guarantee for Breakage, Polar PLOT column, incorporating divinylbenzene ethylene glycol/dimethylacrylate. Highly inert for the analysis of polar and nonpolar compounds
Rt-QS-BOND Column 8um. Rt-QS-BOND Column, fused silica PLOT, Length: 15m, 0.25mm ID, Df: 8um, Intermediate polarity porous polymer PLOT column incorporating low 4-vinylpyridine. Separates ethane, ethylene, and acetylene to baseline. Stable to 250 deg C. Similar Phase(s): GS-Q
Rt-QS-BOND Column 8um. Rt-QS-BOND Column, fused silica PLOT, Length: 30m, 0.25mm ID, Df: 8um, Intermediate polarity porous polymer PLOT column incorporating low 4-vinylpyridine. Separates ethane, ethylene, and acetylene to baseline. Stable to 250 deg C. Similar Phase(s): GS-Q
Rt-Q-BOND Column 10um. Rt-Q-BOND Column, Length: 15m, 0.25mm ID, Df: 8um, Nonpolar PLOT column incorporating 100% divinylbenzene. High retention for CO2 simplifies gas analysis; CO2 and methane separated from O2/N2/CO, for analysis of oxygenated compounds and solvents. Temperature of 300 deg C
Rt-S-BOND Column 8um. Rt-S-BOND Column, fused silica PLOT, Length: 15m, 0.25mm ID, Df: 8um, Midpolarity porous polymer PLOT column, incorporating high 4-vinylpyridine. Use for the analysis of nonpolar and polar compounds. Stable to 250 deg C. Similar Phase(s): CP-PoraPLOT S
Rt-S-BOND Column 8um. Rt-S-BOND Column, fused silica PLOT, Length: 30m, 0.25mm ID, Df: 8um, Midpolarity porous polymer PLOT column, incorporating high 4-vinylpyridine. Use for the analysis of nonpolar and polar compounds. Stable to 250 deg C. Similar Phase(s): CP-PoraPLOT S
Rt-U-BOND Column 8um. Rt-U-BOND Column, fused silica PLOT, Length: 15M, ID: 0.25mm, Df: 8um, No Cage, No Guarantee for Breakage, Polar PLOT column, incorporating divinylbenzene ethylene glycol/dimethylacrylate. Highly inert for the analysis of polar and nonpolar compounds
Rt-U-BOND Column 8um. Rt-U-BOND Column, fused silica PLOT, Length: 30M, ID: 0.25mm, Df: 8um, No Cage, No Guarantee for Breakage, Polar PLOT column, incorporating divinylbenzene ethylene glycol/dimethylacrylate. Highly inert for the analysis of polar and nonpolar compounds
Rtx-65TG Column 10um. Rtx-65TG Column, Length: 30m, 0.25mm ID, Df: 0.10um, fused silica, high-polarity phase; Crossbond diphenyl dimethyl polysiloxane, Application-specific columns, specially tested for triglycerides. Stable to 370 deg C.
Rtx-VMS Column 1.44um. Rtx-VMS Column, fused silica, Length: 30m, 0.25mm ID, Df: 1.4um, proprietary Crossbond phase, Application-specific columns for analyzing volatile organic pollutants by GC-MS including Methods TO-15, TMS, and EPA 8260. Stable to 260 deg C.
Stabilwax Column 1um. Stabilwax Column, fused silica, with 10m Integra-Guard, Length: 15m, ID: 0.53mm, Df: 1um, For HP 6850 GCs, polar phase; Crossbond polyethylene glycol, Rugged enough to with stand repeated water injections. Temperature range: 40 deg C to 260 deg C.
Stabilwax Capillary Column, Length: 1.1m (+or-3cm), ID: 0.10mm, Df: 0.10um.
Rtx-CLP1 Capillary Column, Length: 1.1m (+or-3cm) 0.10mm ID, DF: 0.10um.
Rxi-1ms Column 1um. Rxi-1ms Column, fused silica, Length: 1.1m (+or-3cm), 0.10mm ID, Df: 0.10um, nonpolar phase; Crossbond dimethyl polysiloxane, General-purpose columns for arson accelerants, essential oils, hydrocarbons, pesticides, PCB congeners (e.g, Aroclor mixes), sulfur compounds, amines
Rtx-Biodiesel TG Column 0.10um. Rtx-Biodiesel TG Column, fused silica, Guard, Attached w/AlumaSeal Union, Length: 10M, ID: 0.32mm, Df: 0.10um, Low column bleed at high temperatures. For glycerin and glycerides analysis, according to ASTM D6584 and EN 14105 methods. Stable to 350 deg C
Stx-CLPesticides Column 0.32 um. Stx-CLPesticides Column, fused silica with Siltek deactivation), proprietary Crossbond phases, Temperature: -60-320/330 deg C, Internal Diameter: 0.32 mm, df: 0.32 um, Length: 30 m, Application: for organochlorine pesticides and herbicides, Baseline separations
Rxi-17 Column 0.10 um. Rxi-17 Column (fused silica), midpolarity phase; Crossbond diphenyl dimethyl polysiloxane, Temperature: 40-320 deg C, ID: 0.10mm, Length: 1.1m (+or-3cm), df: 0.10 um, Application: for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity
Rtx-Mineral Oil Column (fused silica) 0.30 um. Rtx-Mineral Oil Column (fused silica), Temperature: -60 to 380/400 deg C, Internal Diameter: 0.32 mm, Length: 15 m, df: 0.30 um, Application: for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity
Rxi-624Sil MS Column (fused silica)3.00 um. Rxi-624Sil MS Column (fused silica), midpolarity Crossbond phase, Temperature: -60 to 280/300 deg C, ID: 0.53 mm, Length: 105 m, df: 3.00 um, Application: for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity
Rxi-5Sil MS Column 0.50um. Rxi-5Sil MS Column (fused silica), (low polarity Crossbond silarylene phase), with 5m Integra-guard, Temperature: -60-330/350deg C, ID: 0.32mm, Length: 30m, df: 0.50um, Application: for inertness, ultra-low bleed, reproducible retention, used in ion trap systems
Rxi-5ms Column 0.25 um. Rxi-5ms Column (fused silica), low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, Temperature: -60-330/350deg C, Length: 15m, Internal Diameter: 0.53mm, df: 0.25um, Application: for exceptional inertness, ultra-low bleed, reproducible retention and selectivity
Stabilwax-MS Column 0.25 um. Stabilwax-MS Column (fused silica), High-polarity, stable polyethylene glycol (PEG) stationary phase, Temperature: 40-250/260 deg C, Length: 30 m, ID: 0.32 mm, df: 0.25 um, Application: for purity testing of chemicals, impurities in water matrices, alcoholic beverages.
Rxi-35Sil MS Column 0.50um. Rxi-35Sil MS Column s (fused silica), midpolarity Crossbond phase, Temperature: 50-340/360deg C, ID: 0.32mm, Length: 15 m, df: 0.50um, Application: for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity for substituted polar compounds
Rxi-35Sil MS Column 0.50um. Rxi-35Sil MS Column s (fused silica), midpolarity Crossbond phase, Temperature: 50-340/360deg C, ID: 0.53mm, Length: 15 m, df: 0.50um, Application: for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity for substituted polar compounds
Rxi-35Sil MS Column 0.50um. Rxi-35Sil MS Column s (fused silica), midpolarity Crossbond phase, Temperature: 50-340/360deg C, ID: 0.32mm, Length: 30m, df: 0.50um, Application: for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity for substituted polar compounds
Rxi-17Sil MS Column 0.36 um. Rxi-17Sil MS Column (fused silica), midpolarity Crossbond phase, Temperature: 40 - 340/360deg C, Length: 20 m, Internal Diameter: 0.18 mm, df: 0.36 um, Application: for exceptional inertness, ultra-low bleed, and reproducible retention and selectivity
Rxi-5Sil MS Column 1.00um. Rxi-5Sil MS Column fused silica, low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane, 5m Guard, Temperature:-60 - 320/350deg C, Length: 60m, ID: 0.25mm, df: 1.00um, Application: for inertness, ultra-low bleed, reproducible retention
Rxi-5Sil MS Column 0.10um. Rxi-5Sil MS Column (fused silica), low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane, Temperature:-60 - 320/350deg C, Length: 60m, ID: 0.18mm, df: 0.10um, Application: for exceptional inertness, ultra-low bleed, reproducible retention
Rtx-1 Column 5.00um. Rtx-1 Column (fused silica), nonpolar phase; Crossbond dimethyl polysiloxane, Temperature: -60 to 330/350 deg C, Length: 60 m, ID: 0.32 mm, df: 5.00um, Application: for solvent impurities, PCB congenerssimulated distillation, arson accelerants, essential oils, hydrocarbons
Rtx-5 (G27) Column 1um. Rtx-5 (G27) Column s (fused silica), low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, Temperature: -60-325/350 deg C, ID: 0.32mm, Length: 60m, df: 1um, Application: for drugs, solvent impurities, pesticides, PCB congeners, essential oils, semivolatiles.
Rtx-5 (G27) Column 3.00um. Rtx-5 (G27) Column s (fused silica), low-polarity phase; Crossbond diphenyl dimethyl polysiloxane, Temperature: -60-325/350 deg C, ID: 0.53mm, Length: 30m, df: 3.00um, Application: for solvent impurities, pesticides, PCB congeners, essential oils, semivolatiles.
Rxi-17Sil MS Secondary Column 0.15 um. Rxi-17Sil MS Secondary Column (fused silica), midpolarity Crossbond phase, Temperature: 40 - 340/360deg C, Length: 2m, Internal Diameter: 0.15 mm, df: 0.15 um, Application: for exceptional inertness, ultra-low bleed, reproducible retention and selectivity
Rxi-17Sil MS Secondary Column 0.25 um. Rxi-17Sil MS Secondary Column (fused silica), midpolarity Crossbond phase, Temperature: 40 - 340/360deg C, Length: 2m, Internal Diameter: 0.25 mm, df: 0.25 um, Application: for exceptional inertness, ultra-low bleed, reproducible retention and selectivity
Rxi-5Sil MS Column 2.0um. Rxi-5Sil MS Column (fused silica), low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane, Temperature:-60 - 320/350deg C, Length: 20m, ID: 0.15mm, df: 2.0um, Application: for exceptional inertness, ultra-low bleed, reproducible retention
Rtx-1 PONA Capillary Column, length: 50m, Internal Diameter: 0.25mm, df: 0.5um.
Rxi-35Sil MS Column 1um. Rxi-35Sil MS Column fused silica, Length: 30m, ID: 0.25mm, df: 1um, midpolarity Crossbond phase, Special selectivity and excellent inertness for substituted polar compounds, Provides superior separation for cannabinoids
Rxi-35Sil MS Column 1um. Rxi-35Sil MS Column fused silica, Length: 30m, ID: 0.32mm, df: 1um, midpolarity Crossbond phase, Special selectivity and excellent inertness for substituted polar compounds, Provides superior separation for cannabinoids
Rxi-35Sil MS Column 3um. Rxi-35Sil MS Column fused silica, Length: 30m, ID: 0.53mm, df: 3um, midpolarity Crossbond phase, Special selectivity and excellent inertness for substituted polar compounds, Provides superior separation for cannabinoids
Rxi-5Sil MS Secondary Column for GCxGC 0.18mm. Rxi-5Sil MS Secondary Column for GCxGC fused silica, Length: 2m, ID: 0.18mm, df: 0.18um, low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane, Engineered to be a low bleed GC/MS column, Excellent inertness
Rxi-5Sil MS Secondary Column for GCxGC 0.25um. Rxi-5Sil MS Secondary Column for GCxGC fused silica, Length: 2m, ID: 0.25mm, df: 0.25um, low-polarity phase; Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane, Engineered to be a low bleed GC/MS column, Excellent inertness
Stabilwax Column 0.15um. Stabilwax Column fused silica, Length: 10m, ID: 0.15mm, df: 0.15um, polar phase; Crossbond polyethylene glycol, Rugged enough to withstand repeated water injections, Low-bleed PEG column ensures long column lifetimes, Temperature range: 40 deg C to 260 deg C
Rtx-5MS Capillary GC Column length: 15m, 0.25mm id, Df: 0.50um, with 10m Integra-Guard Column, incorporate both guard column and analytical column in a continuous length of tubing, guard column is marked separately from the analytical column, using high temperature
Rtx-440 Column 0.25um. Rtx-440 Column fused silica, Length: 30m, ID: 0.32, df: 0.25um, midpolarity proprietary Crossbond phase, with 10m, 0.25 Integra-Guard, General-purpose columns with unique selectivity for pesticides, PAHs, Low-bleed, high-resolution columns with unique selectivity
Rtx-1301 (G43) Column 0.25um. Rtx-1301 (G43) Column, fused silica, Length: 30m, ID: 0.25mm, df: 0.25um, low- to midpolarity phase, General-purpose columns for residual solvents, alcohols, oxygenates, and volatile organic compounds, Equivalent to USP G43 phase, Similar Phase(s): DB-1301, DB-624
Rtx-1701 Column 0.25um. Rtx-1701 Column, fused silica, Length: 15m, ID: 0.25mm, df: 0.25um, midpolarity Crossbond phase, with 10m Integra-Guard, General-purpose columns for alcohols, oxygenates, PCB congeners, pesticides, and fragrance compounds, Equivalent to USP G46 phase
GCxGC Selectivity Kit 0.25 mm. GCxGC Selectivity Kit, ID: 0.25 mm, Wide range of stationary phases, High thermal stability increases system ruggedness, Unrivaled column inertness for accurate analysis of active compounds, Includes: Press-Tight connectors offer a reliable, hassle-free installation
GCxGC Selectivity Kit 0.15 mm. GCxGC Selectivity Kit, ID: 0.15 mm, Wide range of stationary phases, High thermal stability increases system ruggedness, Unrivaled column inertness for accurate analysis of active compounds, Includes: Press-Tight connectors offer a reliable, hassle-free installation
Rtx-PCB Column 0.25um. Rtx-PCB Column, fused silica, Length: 30m, ID: 0.25mm, df: 0.25um, proprietary Crossbond phase, Unique polymer for PCBs analysis by GC-ECD or GC-MS, Good results for other semivolatiles, Low polarity; inert to active compounds, Stable to 340 deg C
Rxi-5ms Column 0.10um. Rxi-5ms Column, fused silica, Length: 10m, ID: 0.10mm, df: 0.10um, low polarity phase, Crossbond 5% diphenyl/95% dimethyl polysiloxane, General purpose columns for semivolatiles, phenols, amines, residual solvents, drugs of abuse, pesticides, Equivalent to USP G27 phase
Rxi-XLB Column 0.50um. Rxi-XLB Column, fused silica, Length: 30m, ID: 0.53mm, df: 0.50um, low polarity proprietary phase, General purpose column with unique selectivity and extremely low bleed, Ideal for many GC/MS applications pesticides, PCB congeners, Aroclor mixes, and PAHs
Rxi-1HT Column 0.10um. Rxi-1HT Column, fused silica, Length: 15m, ID: 0.32mm, df: 0.10um, nonpolar phase; dimethyl polysiloxane, 40% longer lifetime from specially designed fused silica tubing, Columns processed for high-temperature applications, such as high molecular weight hydrocarbons
Rxi-1HT Column 0.10um. Rxi-1HT Column, fused silica, Length: 30m, ID: 0.32mm, df: 0.10um, nonpolar phase; dimethyl polysiloxane, 40% longer lifetime from specially designed fused silica tubing, Columns processed for high-temperature applications, such as high molecular weight hydrocarbons
Rxi-1HT Column 0.25um. Rxi-1HT Column, fused silica, Length: 30m, ID: 0.32mm, df: 0.25um, nonpolar phase; dimethyl polysiloxane, 40% longer lifetime from specially designed fused silica tubing, Columns processed for high-temperature applications, such as high molecular weight hydrocarbons
Stabilwax Secondary Columns for GCxGC 0.15um. Stabilwax Secondary Columns for GCxGC, fused silica, Length: 2m, ID:0.15mm, df: 0.15um, polar phase; Crossbond polyethylene glycol, Convenient 2 m length is ideal for use as a secondary column, Rugged enough to withstand repeated water injections
Stabilwax Secondary Columns for GCxGC 0.18um. Stabilwax Secondary Columns for GCxGC, fused silica, Length: 2m, ID:0.18mm, df: 0.18um, polar phase; Crossbond polyethylene glycol, Convenient 2 m length is ideal for use as a secondary column, Rugged enough to withstand repeated water injections
Stabilwax Secondary Columns for GCxGC 0.25um. Stabilwax Secondary Columns for GCxGC, fused silica, Length: 2m, ID:0.25mm, df: 0.25um, polar phase; Crossbond polyethylene glycol, Convenient 2 m length is ideal for use as a secondary column, Rugged enough to withstand repeated water injections
Rtx-440 Column 20m 0.18mm ID 0.18um. Rtx-440 Column, (fused silica), midpolarity proprietary Crossbond phase, Temp. Limits: 20 to 320 C, Length: 20 m, ID: 0.18 mm, df (um): 0.18 um, columns with unique selectivity for pesticides, PAHs, or other semivolatiles. Ideal for low/trace-level analyses
Rxi-XLB Column 10m 0.10mm ID 0.10um. Rxi-XLB Column, (fused silica), low-polarity proprietary phase, Temp. Limits: 30 to 340/360 C, Length: 10 m, ID: 0.10 mm, df (um): 0.10 um, General-purpose columns exhibiting extremely low bleed. Ideal for many GC-MS applications, including pesticides
Rtx-200 Column 20m 0.15mm ID 0.15um. Rtx-200 Column, (Fused Silica) midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane, Temp. Limits: -20 to 320/340 C, Length: 20 m, ID: 0.15 mm, df (um): 0.15 um, General-purpose columns for solvents, Freon fluorocarbons, alcohols
Rxi-PAH Column 30m 0.25mm ID 0.10um. Rxi-PAH Column, (Fused silica) midpolarity proprietary phasel, Temp. Limits: to 350/360 C, Length: 30 m, ID: 0.25 mm, df (um): 0.10 um, Complete separation of benzo [b], [k], [ j], and [a] fluoranthenes, allows analysis of low-volatility dibenzo pyrenes
Selectivity Kit (0.18 mm). Selectivity Kit (0.18 mm), Includes: Rxi-1ms Column, Rxi-5Sil MS Column, Rxi-XLB Column, Rxi-17Sil MS Column, Rtx-200 Column, Stabilwax Column, and a 5-pk. Of Deactivated Universal Press-Tight Connectors, Wide range of stationary phases offers orthogonal separations,
Rxi-1 MS Secondary Column 2m. Rxi-1 MS Secondary Column for GCxGC, (fused silica), nonpolar phase; Crossbond dimethyl polysiloxane, Length: 2m, ID: 0.18 mm, Film Thickness: 0.18 um, Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses, Temp range: -60 C to 330/350 C
Rxi-1 MS Secondary Column 2m. Rxi-1 MS Secondary Column for GCxGC, (fused silica), nonpolar phase; Crossbond dimethyl polysiloxane, Length: 2m, ID: 0.25 mm, Film Thickness: 0.25 um, Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses, Temp range: -60 C to 330/350 C
Rxi-1ms Column 20m. Rxi-1ms Column, (fused silica), nonpolar phase; Crossbond dimethyl polysiloxane, Length: 20m, ID: 0.15 mm, Film Thickness: 2.0 um, General-purpose columns for arson accelerants, essential oils, hydrocarbons, pesticides, PCB congeners (e.g, Aroclor mixes)
Rxi-XLB Secondary Column 2m. Rxi-XLB Secondary Column(fused silica), low polarity proprietary phase, Length: 2 m, ID: 0.15 mm, Film Thickness: 0.15 um, Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses, General purpose columns exhibiting extremely low bleed
Rtx-200 Secondary Column 2m. Rtx-200 Secondary Column(fused silica), midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane, Length: 2 m, ID: 0.18 mm, Film Thickness: 0.18um, Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses, General purpose column
Rxi-XLB Secondary Column 2m. Rxi-XLB Secondary Column(fused silica), low polarity proprietary phase, Length: 2 m, ID: 0.18 mm, Film Thickness: 0.18um, Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses, General purpose columns exhibiting extremely low bleed
Rtx-200 Secondary Column 2m. Rtx-200 Secondary Column(fused silica), midpolarity phase; Crossbond trifluoropropylmethyl polysiloxane, Length: 2 m, ID: 0.25mm, Film Thickness: 0.25um, Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses, General purpose column
Rxi-XLB Secondary Column 2m. Rxi-XLB Secondary Column(fused silica), low polarity proprietary phase, Length: 2 m, ID: 0.25mm, Film Thickness: 0.25um, Convenient 2 m length is ideal for use as a secondary column in GCxGC analyses, General purpose columns exhibiting extremely low bleed
MXT-1HT column SIMDIST 10M. MXT-1HT SimDist Column (Siltek-treated stainless steel) nonpolar phases, Length: 10M, ID: 0.53mm, Film Thickness: 0.21um, with on 11-Pin Cage, Lowest bleed for longest column lifetime,100% dimethyl polysiloxane phase allows easy comparisons to historical data
Rt-Alumina BOND/KCl Column 30m. Rt-Alumina BOND/KCl Column, Length: 30 m, ID: 0.32mm, Film Thickness: 5um, Low moisture sensitivity reduces the need for frequent regeneration, Acetylene elutes before n-butane, Methyl acetylene (impurity in 1,3-butadiene) elutes before 1,3-butadiene
MXT Alumina BOND/Na2SO4 Column 10um. MXT Alumina BOND/Na2SO4 Column(Siltek treated stainless steel PLOT), Length: 30m, ID: 0.53mm, df: 10um, Config: 3.5inch,Temperature: 200 deg C, Equivalent to USP G43 phase, Rugged material, Designed for robust performance in process GCs and field instruments
MXT Alumina BOND/MAPD Column 10um. MXT Alumina BOND/MAPD Column (Siltek treated stainless steel PLOT), Length: 30m, ID: 0.53mm, df: 10um, Temperature: 250 deg C, Config: 3.5 inch OD without cage, Application: analysis of petrochemicals and ethylene, propylene, butylenes, and butadiene
MXT 1HT Sim Dist Column 1.2um. MXT 1HT Sim Dist Column (Siltek treated stainless steel), nonpolar phase; 100% dimethyl polysiloxane phase, Length: 10m, ID: 0.53mm, df: 1.2um, Config: 11-Pin Cage, Temperature: -60 to 450 deg C, Coil diameter: 7 inch, Lowest bleed for longest column lifetime
MXT 1HT Sim Dist Column 2.65um. MXT 1HT Sim Dist Column (Siltek treated stainless steel), nonpolar phase; 100% dimethyl polysiloxane phase, Length: 10m, ID: 0.53mm, df: 2.65um, Temperature: -60 to 400 deg C, Coil diameter: 7 inch, Config: 11-pin cage, Meets all ASTM D2887, D7500 specifications
MXT 1HT Sim Dist Column 0.88um. MXT 1HT Sim Dist Column (Siltek treated stainless steel), nonpolar phase; 100% dimethyl polysiloxane phase, Length: 10m, ID: 0.53mm, df: 0.88um, Temperature: -60 to 400 deg C, Coil diameter: 7 inch, Config: 11-pin cage, Meets all ASTM D2887, D7500 specifications
MXT Msieve 5A Column 50um. MXT Msieve 5A Column (Siltek treated stainless steel PLOT), Length: 30m, ID: 0.53mm, df: 50um, Config: 3.5 inch,Temperature: 200 deg C, Equivalent to USP G43 phase, Rugged material, Designed for robust performance in process GCs and field instrument, capillary column
MXT 1HT Sim Dist Column 1um. MXT 1HT Sim Dist Column (Siltek treated stainless steel), nonpolar phase; 100% dimethyl polysiloxane phase, Length: 10m, ID: 0.53mm, df: 1um, Temperature: -60 to 400 deg C, Coil diameter: 7 inch, Config: 11-pin cage, Meets all ASTM D2887, D7500 specifications
MXT 1HT Sim Dist Column 5um. MXT 1HT Sim Dist Column (Siltek treated stainless steel), nonpolar phase; 100% dimethyl polysiloxane phase, Length: 10m, ID: 0.53mm, df: 5um, Temperature: -60 to 400 deg C, Coil diameter: 7 inch, Config: 11-pin cage, Meets all ASTM D2887, D7500 specifications
MXT Alumina BOND/Na2SO4 Column 10um. MXT Alumina BOND/Na2SO4 Column (Siltek treated stainless steel PLOT), Length: 30m, ID: 0.53mm, df: 10um, Temperature: 200 deg C, Equivalent to USP G43 phase, Rugged material, Designed for robust performance in process GCs and field instruments
MXT Q-BOND Column 20um. MXT Q-BOND Column (Siltek treated stainless steel PLOT), Length: 30m, ID: 0.53mm, df: 20um, Config: with 3.5 inch Coil,Temperature: 280/300 deg C, Equivalent to USP G43 phase, Rugged material, Designed for robust performance in process GCs and field instruments
MXT Biodiesel TG Column (Siltek treated stainless steel), Length: 2m, ID: 0.53mm, Retention Gap, Temperature: -60 to 380/430 deg C, Config: 7 inch 11-pin cage, Fast analysis times and sharp mono-, di-, and triglyceride peaks for reliable, consistent performance
MXT Alumina BOND/MAPD Column 10um. MXT Alumina BOND/MAPD Column (Siltek treated stainless steel PLOT), Length: 30m, ID: 0.53mm, df: 10um, Temperature: 250 deg C, Config: 7 inch 11-pin cage, Application: analysis of petrochemicals and ethylene, propylene, butylenes, and butadiene
MXT Biodiesel TG Column 0.10um. MXT Biodiesel TG Column (Siltek treated stainless steel), Length: 10m, ID: 0.32mm, df: 0.10um, Temperature: -60 to 380/430 deg C, Config: 7 inch 11-pin cage, Fast analysis times and sharp mono-, di-, and triglyceride peaks for reliable, consistent performance
MXT Biodiesel TG Column 0.10um. MXT Biodiesel TG Column (Siltek treated stainless steel), Length: 15m, ID: 0.32mm, df: 0.10um, Temperature: -60 to 380/430 deg C, Config: 7 inch 11-pin cage, Fast analysis times and sharp mono-, di-, and triglyceride peaks for reliable, consistent performance
Rt QS-BOND Column 10um. Rt QS-BOND Column (fused silica PLOT), porous divinylbenzene homopolymer, Intermediate polarity incorporating low 4-vinylpyridine, Length: 15m, ID: 0.32mm, df: 10um, Temperature: Stable to 250 deg C, Application: Separates ethane, ethylene, and acetylene to baseline
Rt S-BOND Column 20um. Rt S-BOND Column (fused silica PLOT), porous divinylbenzene homopolymer, Midpolarity porous polyme, incorporating high 4-vinylpyridine, Length: 15m, ID: 0.53mm, df: 20um, Temperature: Stable to 250 deg C, Application: Use for the analysis of nonpolar and polar compounds
MXT Q-BOND Column 15m. MXT Q-BOND Column, Siltek treated stainless steel PLOT, Rugged material withstands rough handling and shock, Designed for robust performance in process GCs, Temperature range: 280-300 deg CConfig: 7in 11-pin cage, Length: 15m, Internal Diameter: 0.25mm, df: 8um
MXT 1 Column 15m. MXT 1 Column, Siltek treated stainless steel, nonpolar phase, Crossbond dimethyl polysiloxane, Temperature range: -60-430 Deg C, Equivalent to USP G1, G2, G38 phases, 4.5in standard coil diameter, for solvent impurities, Length: 15m, Internal Diameter: 0.53mm, df: 0.15um
Stx-CLPesticides Kit, Contains, Stx-CLPesticides Column, Stx-CLPesticides2 Column, Universal Angled Y Press-Tight Connector, and Siltek Guard, Stable to 330 degree C, Application-specific Column for organochlorine pesticides and herbicides, 0.32mm ID
Rxi 5Sil MS Column 30m. Rxi 5Sil MS Column, low-polarity phase, Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane, Temperature range: -60 Deg C to 350 Deg C, ideal for GC-MS analysis of semivolatiles, Low-bleed GC-MS column, Length: 30m, Internal Diameter: 0.25mm, df: 0.25um
Stabilwax DA Column 30m. Stabilwax DA Column, fused silica, polar phase, Crossbond base-deactivated Carbowax polyethylene glycol-for amines and basic compounds, Temperature range: 40 to 260 deg C, Equivalent to USP G25, G35 phases, Length: 30 m, Internal Diameter: 0.25mm, df: 0.50um
Rxi 624Sil MS Column 20m. Rxi 624Sil MS Column, fused silica, midpolarity Crossbond phase, Temperature range: -20 Deg C to 320 Deg C, Low-bleed, high-thermal stability, excellent peak shape for a wide range of compounds, Length: 20m, Internal Diameter: 0.18mm, df: 1.0um
Rxi 624Sil MS Column 30m. Rxi 624Sil MS Column, fused silica, midpolarity Crossbond phase, Temperature range: -20 Deg C to 320 Deg C, Low-bleed, high-thermal stability, excellent peak shape for a wide range of compounds, Length: 30m, Internal Diameter: 0.25mm, df: 1.4um
Rtx 5 DHA Tuning Column 5m. Rtx 5 DHA Tuning Column, fused silica, Crossbond 5% diphenyl/95% dimethyl polysiloxane-optimized for hydrocarbon analysis, Temperature range: -60 Deg C to 350 Deg C, Length: 5m, Internal Diameter: 0.25mm, df: 1.0um
Rtx VolatileAmine Column 60m. Rtx VolatileAmine Column, fused silica, Unique selectivity for baseline resolution of all volatile amines, Temperature Range: -60 to 290 deg C, Excellent inertness assures accuracy and sensitivity for volatile amines, Length: 60m, Internal Diameter: 0.32mm
Rxi 5Sil MS Column15m. Rxi 5Sil MS Column, low-polarity phase, Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane, Temperature range: -60 Deg C to 350 Deg C, ideal for GC-MS analysis of semivolatiles, Low-bleed GC-MS column, Length: 15m, Internal Diameter: 0.25mm, df: 0.25um
Rxi 5Sil MS Column30m. Rxi 5Sil MS Column, low-polarity phase, Crossbond 1,4-bis(dimethylsiloxy)phenylene dimethyl polysiloxane, Temperature range: -60 Deg C to 350 Deg C, ideal for GC-MS analysis of semivolatiles, Low-bleed GC-MS column, Length: 30m, Internal Diameter: 0.25mm, df: 0.50um
Category
Ambulatory Equipment
Apparel
Appliances (Durable Goods)
Body Pressure Relief and Positioning
Clinical Laboratory
Diagnostic Instruments and Supplies
Drainage and Suction
Furnishings
Gloves
Housekeeping
Implants
Incontinence
Indicators and Signage
Instruments
IV Therapy
Needles and Syringes
Nurse's Station and Office Supplies
Nutritionals and Feeding Supplies
Orthopedic
Ostomy
other
Personal Hygiene
Pharmaceuticals
Physical Therapy
Respiratory
Services
Sterilization
Textiles
Training and Education
Urological
Utensils
Ventilators
Wound Care
Wound Closure
Prev
10
11
12
13
14
Next