About Us
Login
Retail Customer Login
Business User Login
Registration
Retail Customer Registration
Business User Registration
0
Shop Products
Ambulatory Equipment
Apparel
Appliances (Durable Goods)
Body Pressure Relief and Positioning
Clinical Laboratory
Diagnostic Instruments and Supplies
Drainage and Suction
Furnishings
Gloves
Housekeeping
Implants
Incontinence
Indicators and Signage
Instruments
IV Therapy
Needles and Syringes
Nurse's Station and Office Supplies
Nutritionals and Feeding Supplies
Orthopedic
Ostomy
other
Personal Hygiene
Pharmaceuticals
Physical Therapy
Respiratory
Services
Sterilization
Textiles
Training and Education
Urological
Utensils
Ventilators
Wound Care
Wound Closure
0
Retail Customer Login
Business User Login
Retail Customer Registration
Business User Registration
Shop Products
Ambulatory Equipment
Apparel
Appliances (Durable Goods)
Body Pressure Relief and Positioning
Clinical Laboratory
Diagnostic Instruments and Supplies
Drainage and Suction
Furnishings
Gloves
Housekeeping
Implants
Incontinence
Indicators and Signage
Instruments
IV Therapy
Needles and Syringes
Nurse's Station and Office Supplies
Nutritionals and Feeding Supplies
Orthopedic
Ostomy
other
Personal Hygiene
Pharmaceuticals
Physical Therapy
Respiratory
Services
Sterilization
Textiles
Training and Education
Urological
Utensils
Ventilators
Wound Care
Wound Closure
$
Go Back
1700 Series-Removable Needle Syringe, Point Style 3. For Rheodyne, Altex, VALCO VISF-2, Beckman/Altex, and SSI Injectors. Cut at 90[degree] bevel. Ideal for pipetting liquids. Carries less dead volume than standard bore. Advantageous in piercing septa. Needle length: 5.1cm. Volume: 50uL. 22S gauge.
1700 Series-Removable Needle Syringe, Point Style 3. For Rheodyne, Altex, VALCO VISF-2, Beckman/Altex, and SSI Injectors. Cut at 90[degree] bevel. Ideal for pipetting liquids. Carries less dead volume than standard bore. Advantageous in piercing septa. Needle length: 5.1cm. Volume: 100uL. 22S gauge.
1700 Series-Removable Needle Syringe, Point Style 3. For Rheodyne, Altex, VALCO VISF-2, Beckman/Altex, and SSI Injectors. Cut at 90[degree] bevel. Ideal for pipetting liquids. Needle length: 5.1cm. Volume: 250uL. 22 gauge.
1700 Series-Removable Needle Syringe, Point Style 3. For Rheodyne, Altex, VALCO VISF-2, Beckman/Altex, and SSI Injectors. Cut at 90[degree] bevel. Ideal for pipetting liquids. Needle length: 5.1cm. Volume: 500uL. 22 gauge.
7000 Series MODIFIED MICROLITER Syringe, Point Style 2. Used with liquids. For applications requiring the puncturing of a septum. Cut at a 22[degree] bevel with tip slightly bent. Advantageous in piercing septa. Tungsten plunger wire. Needle length: 70mm. Volume: 0.5uL. 25 gauge.
7000 Series MODIFIED MICROLITER Syringe, Point Style 2. Used with liquids. For applications requiring the puncturing of a septum. Cut at a 22[degree] bevel with tip slightly bent. Advantageous in piercing septa. Tungsten plunger wire. Needle length: 70mm. Volume: 1uL. 22S small bore gauge.
7000 Series MODIFIED MICROLITER Syringes, Point Style 2. Used with liquids. For applications requiring the puncturing of a septum. Cut at a 22[degree] bevel with tip slightly bent. Advantageous in piercing septa. Tungsten plunger wire. Needle length: 70mm. 25 gauge. Volume: 2uL.
7000 Series MODIFIED MICROLITER Syringe, Point Style 2. Used with liquids. For applications requiring puncturing septum. Cut at 22[degree] bevel with tip slightly bent to help prevent septum coring. Advantageous in piercing septa. Tungsten plunger wire. Needle length: 70mm. Volume: 2uL. 23 gauge.
7000 Series MODIFIED MICROLITER Syringe, Point Style 2. Used with liquids. For applications requiring puncturing septum. Cut at 22[degree] bevel with tip slightly bent to help prevent septum coring. Advantageous in piercing septa. Tungsten plunger wire. Needle length: 70mm. Volume: 5uL. 24 gauge.
Chaney Adapter. For 7000 Series MODIFIED MICROLITER Syringes, Point Style 2 and 3.
Chaney Adapter. For use with 800 Series MICROLITER Syringes and 1800 Series GASTIGHT Syringes.
Chaney Adapter. For use with 5-10uL 1700 Series GASTIGHT Syringes and 700 Series MICROLITER Syringes.
1700 Series GASTIGHT Removable Needle Syringe, Point Style 2. For Agilent Autosamplers 7670A, 7671A and 7672A. For liquids or gases. Precision-machined fluoropolymer resin tip. Use for puncturing septum. Prevents septum coring. Stainless steel plunger. 5.1cm needle. Volume: 10uL. 26S gauge.
Fused Silica Needle On-Column Syringe, MICROLITER, 10 uL. Model: 701RNFS. Volume: 10 uL. O.D./Length/Point style: (.17 mm/11.5 cm/3). Used with capillary column ID's:.20 -.25 mm. External polyimide-coated fused silica Needle. Maximum operating temperature: 360[degree].
Stainless Steel Needle On-Column Syringe, MICROLITER, 10 uL. Model: 701RN. Volume: 10 uL. O.D./Length/Point style: (.23 mm/12.5 cm/2). Used with capillary column ID's:.28 -.35 mm. Cemented Needles (SN) or removable Needles(KHOC, RN) 7.5, 10 and 12.5 cm Needle lengths.
DNA Syringe, 26.5/0.3 mm. Needle gauge: 26.5/.3 mm. Single Channel.
12-Channel, Gel Loading Syringe, for gels 0.4mm. Model: 1701. Volume: 10 uL. Specifications: Syringe Capacity, uL: 10. Scale Length, cm: 6. Total Scale Divisions: 60. Major Graduations, uL: 1. Minor Graduations, uL:.2. Sub-minor Graduations, uL:.5.
800 Series MICROLITER Cemented Needle Syringe, Point Style 2. Used for liquids. For most applications requiring puncturing of a septum. Needle cut at a 22[degree] bevel with tip of the needle slightly bent to prevent septum coring. Small bore. 26 gauge. Needle length: 50.3mm. Volume: 5ul.
800 Series MICROLITER Removable Needle Syringe, Point Style 2. Used for liquids. For most applications requiring puncturing of a septum. Needle cut at a 22[degree] bevel with tip of the needle slightly bent to prevent septum coring. Small bore. 22 gauge. Needle length: 50.3mm. Volume: 5ul.
800 Series MICROLITER Cemented Needle Syringe, Point Style 2. Used for liquids. For most applications requiring puncturing of a septum. Needle cut at a 22[degree] bevel with tip of the needle slightly bent to prevent septum coring. Small bore. 22 gauge. Needle length: 50.3mm. Volume: 10ul.
GASTIGHT Syringes, 1800RNW, Point Style 3, 250uL. Volume: 250uL. Gauge/Length/Point style: 25s/1.97/3. Used with Injection Valve: WATERS U6K. MICROLITER Syringes. Reinforced plungers. Removable Needles (RNW). Barrel/plunger assemblies are replaceable. GASTIGHT Syringes.
GASTIGHT Syringes, 1800RNW, Point Style 3, 100uL. Volume: 100uL. Gauge/Length/Point style: 25s/1.97/3. Used with Injection Valve: WATERS U6K. MICROLITER Syringes. Reinforced plungers. Removable Needles (RNW). Barrel/plunger assemblies are replaceable. GASTIGHT Syringes.
GASTIGHT Syringes, 1700RNW, Point Style 3, 25uL. Volume: 25uL. Gauge/Length/Point style: 25s/1.97/3. Used with Injection Valve: WATERS U6K. MICROLITER Syringes. Reinforced plungers. Removable Needles (RNW). Barrel/plunger assemblies are replaceable. GASTIGHT Syringes.
GASTIGHT Syringes, 1700RNW, Point Style 3, 100uL. Volume: 100uL. Gauge/Length/Point style: 25s/1.97/3. Used with Injection Valve: WATERS U6K. MICROLITER Syringes. Reinforced plungers. Removable Needles (RNW). Barrel/plunger assemblies are replaceable. GASTIGHT Syringes.
GASTIGHT Syringes, 1700RNW, Point Style 3, 250uL. Volume: 250uL. Gauge/Length/Point style: 25s/1.97/3. Used with Injection Valve: WATERS U6K. MICROLITER Syringes. Reinforced plungers. Removable Needles (RNW). Barrel/plunger assemblies are replaceable. GASTIGHT Syringes.
800 Series MICROLITER Cemented Needle Syringe, Point Style 2. Used for liquids. For most applications requiring puncturing of a septum. Needle cut at a 22[degree] bevel with tip of the needle slightly bent to prevent septum coring. Small bore. 22 gauge. Needle length: 50.3mm. Volume: 25ul.
800 Series MICROLITER Cemented Needle Syringe, Point Style 2. Used for liquids. For most applications requiring puncturing of a septum. Needle cut at a 22[degree] bevel with tip of the needle slightly bent to prevent septum coring. Small bore. 22 gauge. Needle length: 50.3mm. Volume: 50ul.
800 Series MICROLITER Cemented Needle Syringe, Point Style 2. Used for liquids. For most applications requiring puncturing of a septum. Needle cut at a 22[degree] bevel with tip of the needle slightly bent to prevent septum coring. Small bore. 22 gauge. Needle length: 50.3mm. Volume: 100ul.
800 Series MICROLITER Removable Needle Syringe, Point Style 2. Used for liquids. For most applications requiring puncturing of a septum. Needle cut at a 22[degree] bevel with tip of the needle slightly bent to prevent septum coring. Small bore. 22 gauge. Needle length: 50.3mm. Volume: 10ul.
800 Series MICROLITER Removable Needle Syringe, Point Style 2. Used for liquids. For most applications requiring puncturing of a septum. Needle cut at a 22[degree] bevel with tip of the needle slightly bent to prevent septum coring. Small bore. 22 gauge. Needle length: 50.3mm. Volume: 25ul.
800 Series MICROLITER Removable Needle Syringe, Point Style 2. Used for liquids. For applications requiring puncturing of a septum. Cut at a 22[degree] bevel with tip slightly bent to prevent septum coring. Small bore. 22 gauge. Needle length: 50.3mm. Volume: 50ul.
800 Series MICROLITER Removable Needle Syringe, Point Style 2. Used for liquids. For most applications requiring puncturing of a septum. Needle cut at a 22[degree] bevel with tip of the needle slightly bent to prevent septum coring. Small bore. 22 gauge. Needle length: 50.3mm. Volume: 100ul.
800 Series MICROLITER Removable Needle Syringe, Point Style 2. Used for liquids. For most applications requiring puncturing of a septum. Needle cut at a 22[degree] bevel with tip of the needle slightly bent to prevent septum coring. Small bore. 22 gauge. Needle length: 50.3mm. Volume: 250ul.
800 Series MICROLITER Syringe for Waters U6K Injector, Point Style 3. Used for liquids. Has small bore that carries less dead volume than standard bore, and thicker wall that works well in piercing septa. Cut at 90[degree] bevel. Needle length: 50mm. Volume: 25uL. 25S gauge.
800 Series MICROLITER Syringe for Waters U6K Injector, Point Style 3. Used for liquids. Has small bore that carries less dead volume than standard bore, and thicker wall that works well in piercing septa. Cut at 90[degree] bevel. Needle length: 50mm. Volume: 100uL. 25S gauge.
800 Series MICROLITER Syringe for Waters U6K Injector, Point Style 3. Used for liquids. Has small bore that carries less dead volume than standard bore, and thicker wall that works well in piercing septa. Cut at 90[degree] bevel. Needle length: 50mm. Volume: 250uL. 25S gauge.
7000 Series MODIFIED MICROLITER Syringe, Point Style 3. Point style is used on specific HPLC syringes. Removable stainless steel needle. Cut at a 90[degree] bevel and useful for pipetting liquids. Advantageous in piercing septa. Tungsten plunger wire. Length: 70mm. Volume: 0.5ul. 25 gauge.
Microliter™ and Gastight® Built-In Chaney Adapter Syringes, Hamilton Company - 86252, Hamilton Model 7100.5 KHCH Syringe
7000 Series MODIFIED MICROLITER Syringe, Point Style 3. Point style is used on specific HPLC syringes. Removable stainless steel needle. Cut at a 90[degree] bevel and useful for pipetting liquids. Advantageous in piercing septa. Tungsten plunger wire. Length: 100mm. Volume: 0.5ul. 32 gauge.
7000 Series MODIFIED MICROLITER Syringe, Point Style 3. Point style is used on specific HPLC syringes. Removable stainless steel needle. Cut at a 90[degree] bevel and useful for pipetting liquids. Advantageous in piercing septa. Tungsten plunger wire. Length: 70mm. Volume: 1ul. 25 gauge.
7000 Series MODIFIED MICROLITER Syringe, Point Style 3. Point style is used on specific HPLC syringes. Removable stainless steel needle. Cut at a 90[degree] bevel and useful for pipetting liquids. Advantageous in piercing septa. Tungsten plunger wire. Length: 70mm. Volume: 1ul. 22 gauge.
7000 Series MODIFIED MICROLITER Syringe, Point Style 3. Point style is used on specific HPLC syringes. Removable stainless steel needle. Cut at a 90[degree] bevel and useful for pipetting liquids. Advantageous in piercing septa. Tungsten plunger wire. Length: 70mm. Volume: 2ul. 25 gauge.
7000 Series MODIFIED MICROLITER Syringe, Point Style 3. Used with liquids. For applications requiring puncturing septum. Knurled hub. Advantageous in piercing septa. Tungsten plunger wire. Needle length: 70mm. Volume: 2uL. 25 gauge.
7000 Series MODIFIED MICROLITER Syringe, Point Style 3. Point style is used on specific HPLC syringes. Removable stainless steel needle. Cut at a 90[degree] bevel and useful for pipetting liquids. Advantageous in piercing septa. Tungsten plunger wire. Length: 70mm. Volume: 2ul. 23 gauge.
7000 Series MODIFIED MICROLITER Syringe, Point Style 3. Point style is used on specific HPLC syringes. Removable stainless steel needle. Cut at a 90[degree] bevel and useful for pipetting liquids. Advantageous in piercing septa. Tungsten plunger wire. Length: 70mm. Volume: 5ul. 24 gauge.
Microliterâ„¢ Built-In Syringe Guide Syringes, Hamilton Company - 88007, Hamilton Model 7105 KHWG Syringe
Microliter™ and Gastight® Built-In Chaney Adapter Syringes, Hamilton Company - 80104, Hamilton Model 7001 KHCH Syringe
7000 Series MODIFIED MICROLITER Syringe, Point Style 3. Used with liquids. For applications requiring puncturing septum. Knurled hub. Advantageous in piercing septa. Tungsten plunger wire. Needle length: 70mm. Volume: 1uL. 25S gauge.
7000 Series MODIFIED MICROLITER Syringe, Point Style 2. For Agilent Autosamplers 7670A, 7671A and 7672A. Used with liquid. Cut at a 22[degree] bevel with tip slightly bent to prevent coring. For piercing septa. Tungsten plunger wire. 70mm stainless steel needle. Volume: 1uL. 25S small bore gauge.
1700 Series GASTIGHT Fluoropolymer Resin Luer Tip Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of a septum. Volume: 50uL. Does not include a needle.
1700 Series GASTIGHT Fluoropolymer Resin Luer Lock Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of a septum. Volume: 100uL. Does not include a needle.
1700 Series GASTIGHT Fluoropolymer Resin Luer Lock Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of a septum. Volume: 250uL. Does not include a needle.
1700 Series GASTIGHT Removable Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of septum. Carries less dead volume. Prevents septum coring. Needle length: 5.1cm. Volume: 250uL. 22S gauge. Small bore.
1700 Series GASTIGHT Fluoropolymer Resin Luer Lock Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of a septum. Volume: 500uL. Does not include a needle.
1000 Series GASTIGHT Fluoropolymer Resin Luer Lock Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring puncturing of a septum. Does not include a needle. Volume: 1mL.
1000 Series GASTIGHT Fluoropolymer Resin Luer Lock Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring puncturing of a septum. Does not include a needle. Volume: 2.5mL.
Replacement TLL Barrel for Model 1002. Model: 1002. Volume: 2.5 mL.
1000 Series GASTIGHT Fluoropolymer Resin Luer Lock Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring puncturing of a septum. Does not include a needle. Volume: 5mL.
1000 Series GASTIGHT Fluoropolymer Resin Luer Lock Syringes, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring puncturing of a septum. Does not include a needle. Volume: 10mL.
Syringe for Microlab 500 Series Dispensers/Diluters. Reagent syringe (left side). Volume: 25ml. For use with 25227-830 series dispensers/diluters. Note: For dual dispenser models, use reagent (left side) syringes on both sides.
1000 Series GASTIGHT Fluoropolymer Resin Luer Lock Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring puncturing of a septum. Does not include a needle. Volume: 50mL.
1000 Series GASTIGHT Fluoropolymer Resin Luer Lock Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring puncturing of a septum. Does not include a needle. Volume: 100mL.
1800 Series GASTIGHT Cemented Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring the puncturing of a septum. Needle cut to prevent septum coring. Needle length: 5.1cm. Volume: 10uL. 26 gauge.
1800 Series GASTIGHT Cemented Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring the puncturing of a septum. Needle cut to prevent septum coring. Needle length: 5.1cm. Volume: 25uL. 22 gauge.
1800 Series GASTIGHT Cemented Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring the puncturing of a septum. Needle cut to prevent septum coring. Needle length: 5.1cm. Volume: 50uL. 22 gauge.
1800 Series GASTIGHT Cemented Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring the puncturing of a septum. Needle cut to prevent septum coring. Needle length: 5.1cm. Volume: 100uL. 22 gauge.
1800 Series GASTIGHT Cemented Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring the puncturing of a septum. Needle cut to prevent septum coring. Needle length: 5.1cm. Volume: 250uL. 22 gauge.
1800 Series GASTIGHT Removable Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring the puncturing of a septum. Needle cut to prevent septum coring. Needle length: 5.1cm. Volume: 10uL. 26 gauge.
1800 Series GASTIGHT Removable Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring the puncturing of a septum. Needle cut to prevent septum coring. Needle length: 5.1cm. Volume: 25uL. 22 gauge.
1800 Series GASTIGHT Removable Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring the puncturing of a septum. Needle cut to prevent septum coring. Needle length: 5.1cm. Volume: 50uL. 22 gauge.
1800 Series GASTIGHT Removable Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring the puncturing of a septum. Needle cut to prevent septum coring. Needle length: 5.1cm. Volume: 100uL. 22 gauge.
1800 Series GASTIGHT Removable Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring the puncturing of a septum. Needle cut to prevent septum coring. Needle length: 5.1cm. Volume: 250uL. 22 gauge.
1000 Series GASTIGHT Instrument Syringe, AD, 1 ml, Model 1001. Model: 1001. Volume: 1 ml. Specifications: Scale length, cm: 6. Total scale divisions: 50. Major graduations, mL:.1. Minor graduations mL:.02. Max. temp., [degree]C([degree]F): 50[degree]C (122[degree]F).
GASTIGHT Syringe for Hamilton Instruments, 2.5mL, Model 1002AD. Model: 1002AD. Volume: 2.5mL. Recommended Syringes for: MICROLAB 1000 PLUS.
GASTIGHT Syringe for Hamilton Instruments, 5mL, Model 1005AD. Model: 1005AD. Volume: 5mL. Recommended Syringes for: MICROLAB 1000 PLUS.
GASTIGHT Syringe for Hamilton Instruments, 10 mL, Model 1010AD. Model: 1010AD. Volume: 10 mL. Recommended Syringes for: MICROLAB 1000 PLUS.
GASTIGHT Syringe for Hamilton Instruments, 500 uL, Model 1750AD W/S. Model: 1750AD W/S. Volume: 500 uL. Recommended Syringes for: MICROLAB 1000 PLUS.
1700 Series GASTIGHT Luer Tip Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of a septum. Volume: 50uL. Does not include a needle.
CTC/LEAP PAL Technologies LC Autosampler Syringes, Hamilton - 203075, Model 1702 N CTC Syringe
1700 Series GASTIGHT Syringe, Point Style 3. For LEAP Technologies/CTC LC autosamplers. Length: 51mm. Volume: 100uL. 22S gauge. Small bore.
1700 Series GASTIGHT Luer Tip Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of a septum. Volume: 100uL. Does not include a needle.
1700 Series GASTIGHT Luer Tip Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of a septum. Volume: 250uL. Does not include a needle.
1700 Series GASTIGHT Luer Tip Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of a septum. Volume: 500uL. Does not include a needle.
1000 Series GASTIGHT Luer Tip Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring puncturing of a septum. Does not include a needle. Volume: 1mL.
1000 Series GASTIGHT Luer Tip Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring puncturing of a septum. Does not include a needle. Volume: 2.5mL.
1000 Series GASTIGHT Luer Tip Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring puncturing of a septum. Does not include a needle. Volume: 5mL.
1000 Series GASTIGHT Luer Tip Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin plunger tip. For most applications requiring puncturing of a septum. Does not include a needle. Volume: 10mL.
700 Series Special MICROLITER Syringe, 25 uL. Model: 702SN. Volume: 25 uL. Gauge/Length/Point style: 22/2/3. Electrotaper: No. Special Gauge, length, and point style Needle syringes. Cemented Needles (SN). Plungers and barrels are not interchangeable or replaceable.
1700 Series GASTIGHT Removable Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of septum. Carries less dead volume. Prevents septum coring. Needle length: 5.1cm. Volume: 10uL. 26S gauge. Small bore.
1700 Series GASTIGHT Syringe, N (Cemented Needle) Syringe, point style 3, 10 uL, Model 1701. Model: 1701. Volume: 10 uL. Specifications: scale length, cm: 6. Total scale divisions: 60. Major graduations: 1. Minor graduations:.2. Sub minor graduations:.5.
Syringe for Agilent 7673A Autosampler. GASTIGHT cemented needle syringe for liquid/gas. Precision-machined fluoropolymer resin plunger tip. Small bore carries less dead volume than standard bore. Combines durability with performance for split/splitless and on-column injection. 10uL. 23S/26S gauge.
Syringe for Agilent 7673A Autosampler. GASTIGHT removable needle syringe for liquids or gases. Has precision-machined fluoropolymer resin plunger tip. Small bore carries less dead volume than standard bore. Used for standard packed columns and split/splitless injections. Volume: 10uL. 23S gauge.
Syringe for Agilent 7673A Autosampler. GASTIGHT removable needle syringe for liquids and gases. Has precision-machined fluoropolymer resin plunger tip. Small bore carries less dead volume than standard bore. Used for on-column injections and split/splitless injections. Volume: 10uL. 26S gauge.
Syringe for Agilent 7673A Autosampler. GASTIGHT removable needle syringe for liquid/gas. Precision-machined fluoropolymer resin plunger tip. Small bore carries less dead volume than standard bore. Offers durability and performance for split/splitless and on-column injections. 10uL. 23S/26S gauge.
Syringe for Agilent 7673A Autosampler. GASTIGHT cemented needle syringe for liquid/gas. Precision-machined fluoropolymer resin plunger tip. Small bore carries less dead volume than standard bore. Combines durability with performance for split/splitless and on-column injection. 10uL. 23S/26S gauge.
1700 Series GASTIGHT Removable Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of septum. Carries less dead volume. Prevents septum coring. Needle length: 5.1cm. Volume: 25uL. 22S gauge. Small bore.
1700 Series GASTIGHT Removable Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of septum. Carries less dead volume. Prevents septum coring. Needle length: 5.1cm. Volume: 50uL. 22S gauge. Small bore.
1700 Series GASTIGHT Removable Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of septum. Carries less dead volume. Prevents septum coring. Needle length: 5.1cm. Volume: 100uL. 22S gauge. Small bore.
1700 Series GASTIGHT Removable Needle Syringe, Point Style 2. For liquids or gases. Precision-machined fluoropolymer resin tip. For use with applications requiring puncturing of septum. Prevents septum coring. Needle length: 5.1cm. Volume: 500uL. 22 gauge.
1700 Series GASTIGHT Cemented Needle Syringe, Point Style 2. For Agilent Autosamplers 7670A, 7671A and 7672A. For liquids or gases. Precision-machined fluoropolymer resin tip. For applications requiring puncturing of a septum. Prevents septum coring. 5.1cm needle. Volume: 10uL. 26S gauge.
Category
Ambulatory Equipment
Apparel
Appliances (Durable Goods)
Body Pressure Relief and Positioning
Clinical Laboratory
Diagnostic Instruments and Supplies
Drainage and Suction
Furnishings
Gloves
Housekeeping
Implants
Incontinence
Indicators and Signage
Instruments
IV Therapy
Needles and Syringes
Nurse's Station and Office Supplies
Nutritionals and Feeding Supplies
Orthopedic
Ostomy
other
Personal Hygiene
Pharmaceuticals
Physical Therapy
Respiratory
Services
Sterilization
Textiles
Training and Education
Urological
Utensils
Ventilators
Wound Care
Wound Closure
Prev
7
8
9
10
11
Next