logo
  • About Us
    • Retail Customer Login
    • Business User Login
    • Retail Customer Registration
    • Business User Registration
  • 0
  • Shop Products
    • Ambulatory Equipment
    • Apparel
    • Appliances (Durable Goods)
    • Body Pressure Relief and Positioning
    • Clinical Laboratory
    • Diagnostic Instruments and Supplies
    • Drainage and Suction
    • Furnishings
    • Gloves
    • Housekeeping
    • Implants
    • Incontinence
    • Indicators and Signage
    • Instruments
    • IV Therapy
    • Needles and Syringes
    • Nurse's Station and Office Supplies
    • Nutritionals and Feeding Supplies
    • Orthopedic
    • Ostomy
    • other
    • Personal Hygiene
    • Pharmaceuticals
    • Physical Therapy
    • Respiratory
    • Services
    • Sterilization
    • Textiles
    • Training and Education
    • Urological
    • Utensils
    • Ventilators
    • Wound Care
    • Wound Closure
logo
  • 0
  • Retail Customer Login
  • Business User Login
  • Retail Customer Registration
  • Business User Registration
Shop Products
  • Ambulatory Equipment
  • Apparel
  • Appliances (Durable Goods)
  • Body Pressure Relief and Positioning
  • Clinical Laboratory
  • Diagnostic Instruments and Supplies
  • Drainage and Suction
  • Furnishings
  • Gloves
  • Housekeeping
  • Implants
  • Incontinence
  • Indicators and Signage
  • Instruments
  • IV Therapy
  • Needles and Syringes
  • Nurse's Station and Office Supplies
  • Nutritionals and Feeding Supplies
  • Orthopedic
  • Ostomy
  • other
  • Personal Hygiene
  • Pharmaceuticals
  • Physical Therapy
  • Respiratory
  • Services
  • Sterilization
  • Textiles
  • Training and Education
  • Urological
  • Utensils
  • Ventilators
  • Wound Care
  • Wound Closure
$

Grab Passive Air Sampling Kit. Grad Passive Air Sampling Kit, Flow Capacity: 300 mL/min, Orifice Size: 0.0080in, Material: Siltek-Treated, Use with 1, 3, 6 L canisters, Connect 1/4in compression fitting directly to canister valve inlet, Replaceable frit protects orifice and valve from particulates

Grab Passive Air Sampling Kit. Grad Passive Air Sampling Kit, Flow Capacity: 390 mL/min, Orifice Size: 0.0090in, Material: Siltek-Treated, Use with 1, 3, 6 L canisters, Connect 1/4in compression fitting directly to canister valve inlet, Replaceable frit protects orifice and valve from particulates

Grab Passive Air Sampling Kit. Grad Passive Air Sampling Kit, Flow Capacity: 1000 mL/min, Orifice Size: 0.0130in, Material: Siltek-Treated, For 1, 3, 6 L canisters, Connect 1/4in compression fitting directly to canister valve inlet, Replaceable frit protects orifice and valve from particulates

Grab Passive Air Sampling Kit. Grad Passive Air Sampling Kit, Flow Capacity: 80 mL/min, Orifice Size: 0.0040in, Material: Stainless Steel, Use with 1, 3, 6 L canisters, Connect 1/4in compression fitting directly to canister valve inlet, Replaceable frit protects orifice and valve from particulates

Grab Passive Air Sampling Kit. Grad Passive Air Sampling Kit, Flow Capacity: 15 mL/min, Orifice Size: 0.0018in, Material: Stainless Steel, Use with 1, 3, 6 L canisters, Connect 1/4in compression fitting directly to canister valve inlet, Replaceable frit protects orifice and valve from particulates

Grab Passive Air Sampling Kit. Grad Passive Air Sampling Kit, Flow Capacity: 20 mL/min, Orifice Size: 0.0020in, Material: Stainless Steel, Use with 1, 3, 6 L canisters, Connect 1/4in compression fitting directly to canister valve inlet, Replaceable frit protects orifice and valve from particulates

Grab Passive Air Sampling Kit. Grad Passive Air Sampling Kit, Flow Capacity: 45 mL/min, Orifice Size: 0.0030in, Material: Stainless Steel, Use with 1, 3, 6 L canisters, Connect 1/4in compression fitting directly to canister valve inlet, Replaceable frit protects orifice and valve from particulates

Soil Gas Sampler Replacement Tee 30 mL/min. Soil Gas Sampler Replacement Tee with Orifice, Flow Capacity: 30 mL/minute for 3hour, Orifice Size: 0.0025in, Material: Siltek-Treated

Miniature Air Sampling Kit 8 - 15 mL/min. Miniature Air Sampling Kit, Flow Capacity: 8 - 15 mL/min, Orifice Size: 0.0020in, Material: SS, Convenient smaller size connects easily to miniature canisters, Includes: flow controller, critical orifice, 2 um frit filter, vacuum gauge, and sample inlet

Air Liquide Single Stage VOC Regulator, Fittings: CGA-180 (0-100 psig), Material: Stainless Steel, Features: Single-stage, Two pressure gauges, Stainless steel diaphragm and Kel-F seat, Accurate pressure control even at low flow rates, Individually tested

Mini-Can Stand, For Mini can, Collapsible for easy storage and transport, Two out of three legs move to accommodate uneven surfaces, Holds 2 3/4in diameter cans securely, Small footprintG12in diameter x 6.5in height

Thermal Desorption Unit (TDU) Tube. Thermal Desorption Unit (TDU) Tube, Sorbent: Tenax GR (35/60 mesh)/Carbopack B (60/80 mesh), Type: Unconditioned, Material: Stainless Steel, Use corrosion-resistant glass tubes for excellent inertness; allow monitoring of sorbent bed condition

Sample Inlet 6in. Sample Inlet, Material: Siltek-Treated, Length: 6in, with 1/4in SS compression fitting on each end, One end connects to flow controller or canister, nut on other end serves as rain guard, Includes nuts and ferrules, with Two different lengths for large/miniature canisters

Miniature Canister 400cc. Miniature Canister, Modification:without Valve, Material:Siltek-Treated,Volume:400 cc,Ideal for indoor air, personal, emergency response, or soil gas sampling, Dimensions: 7 x 13.6 cm

Pen Clip for Thermal Desorption Unit Tubes.

Thermal Desorption Unit Tube Stainless steel. Thermal Desorption Unit Tube, Calibration, Use corrosion-resistant glass tubes for excellent inertness; allow monitoring of sorbent bed condition, Each tube has an arrow indicating flow direction, Material: Glass

Replacement Battery for Vacuum Bag Sampler Model 1062.

TubeMate Tool for Thermal Desorption Unit Tubes, Benefits and Uses: Assists with tube packing.

Repair Kit, Includes: 1 on/off switch; 2 diaphragms; 2 springs; 4 valve plates; and 11 O-rings, for Chemker 400 Vacuum Pumps

Repair Kit, Includes: 1 on/off switch; 2 diaphragms; 2 springs; 4 valve plates; and 6 O-rings, for Chemker 410 Vacuum Pumps

Repair Kit, Includes: 1 on/off switch; 1 diaphragm; 1 spring; 2 valve plates; and 3 O-rings, For Chemker 300 Vacuum Pumps

Passive Air Sampling Kit-Soil Gas, Flow Capacity: 150 mL/min, Orifice Size: 0.0055in, Material: Stainless Steel, 1 1/2in vacuum gauge (-30in Hg to 0in Hg), 2 um frit filter for insertion into 1/4in compression sample inlet

ALTEF Gas Sampling Bag, Modification: Polypropylene Combo Valve and Septum, Volume: 0.5 L, Size: 6in x 6in, Very low VOC and sulfur background, Durable PVDF film is resistant to abrasion and chemicals, Contain no additives, fillers, or pigment

Passive Air Sampling Kit-Soil Gas, Flow Capacity: 6 mL/min, Orifice Size: 0.0014in, Material: Stainless Steel, 1 1/2in vacuum gauge (-30in Hg to 0in Hg), 2 um frit filter for insertion into 1/4in compression sample inlet

Passive Air Sampling Kit-Soil Gas, Flow Capacity: 19mL/min, Orifice Size: 0.0020in, Material: Stainless Steel, 1 1/2in vacuum gauge (-30in Hg to 0in Hg), 2 um frit filter for insertion into 1/4in compression sample inlet

ALTEF Gas Sampling Bag 28.25in x 30.5in. ALTEF Gas Sampling Bag, Modification: Polypropylene Combo Valve and Septum, 1 eyelet, Volume: 80 L, Size: 28.25x30.5in, Composition: proprietary PVDF film Thickness: 0.003in, Tensile Strength: 6100psi, Temperature: 150 deg C(Max), Specific Gravity: 1.78 g/mL

ALTEF Gas Sampling Bag 24in x 24.25in. ALTEF Gas Sampling Bag, Modification: Polypropylene Combo Valve and Septum, 1 eyelet, Volume: 40 L, Size: 24x24.25in, Composition: proprietary PVDF, film Thickness: 0.003in, Tensile Strength: 6,100 psi, Temperature: 150 deg C (Max), Specific Gravity: 1.78 g/mL

ALTEF Gas Sampling Bag 28in x 36in. ALTEF Gas Sampling Bag, Modification: Polypropylene Combo Valve and Septum, 1 eyelet, Volume: 100 L, Size: 28in x 36in, Composition: proprietary PVDF film, Thickness: 0.003in, Tensile Strength: 6100 psi, Temperature: 150 deg C (Max), Specific Gravity: 1.78 g/mL

ALTEF Gas Sampling Bag 13in x 24in. ALTEF Gas Sampling Bag, Modification: Polypropylene Combo Valve and Septum, 1 eyelet, Volume: 12 L, Size: 13in x 24in, Composition: proprietary PVDF film, Thickness: 0.003in, Tensile Strength: 6,100 psi, Temperature: 150 deg C (Max), Specific Gravity: 1.78 g/mL

Small Cylinder Stand 6.5in. Small Cylinder Stand, Supports and stabilizes disposable gas cylinders, Fits cylinders up to 3 3/8in in diameter, Adjustable screw secures cylinder in place, Base diameter: 7.75in, Total height: 6.5in

Passive Air Sampling Kit-Soil Gas, Flow Capacity: 80 mL/min, Orifice Size: 0.0040in, Material: Stainless Steel, 1 1/2in vacuum gauge (-30in Hg to 0in Hg), 2 um frit filter for insertion into 1/4in compression sample inlet

Thermal Desorption Unit Tube, Empty tubes for direct desorption of VOCs from liquids, solids, or pastes, Material: Glass, glass frit positioned 15 mm from sampling end, Empty tubes for direct desorption of VOCs from liquids

Belt Extension for Aura Personal Air Sampler, Length: adjustable, 12-24in (30.5-61 cm).

Thermal Desorption Unit (TDU) Tube. Thermal Desorption Unit (TDU) Tube, Sorbent: Tenax TA (35/60 mesh), Type: Unconditioned, Material: Glass, Use corrosion-resistant glass tubes for excellent inertness; allow monitoring of sorbent bed condition, Individually etched

Aura Personal Air Sampler (Disposable 8-Hour Sampler Line).

Sample Inlet 6in. Sample Inlet, Material: Stainless Steel, Length: 6in, with 1/4in SS compression fitting on each end, One end connects to flow controller or canister, nut on other end serves as rain guard, Includes nuts and ferrules, with Two different lengths for large/miniature canisters

Thermal Desorption Unit (TDU) Tube. Thermal Desorption Unit (TDU) Tube, Sorbent: Graphitized Carbon (20/40 mesh), Type: Conditioned & Capped, Material: Stainless Steel, Individually etched with unique serial number for convenient sample identification

Soil Gas Sampling Kit, Flow Capacity: 30 mL/min, Material: Stainless Steel, Orifice Size: 0.0025in, Includes: Tee with orifice for sampling from 4 minutes to 10 hours, 1-1/2in vacuum gauge (-30 to 0 in Hg), 2 um frit filter for insertion into 1/4in compression sample inlet

Replacement Fitting for Grab Sampling Kit, Orifice Size: 0.0018in, Material: Siltek-Treated, Includes fitting and orifice

Replacement Fitting for Grab Sampling Kit, Orifice Size: 0.0020in, Material: Siltek-Treated, Includes fitting and orifice

Replacement Fitting for Grab Sampling Kit, Orifice Size: 0.0030in, Material: Siltek-Treated, Includes fitting and orifice

Replacement Fitting for Grab Sampling Kit, Orifice Size: 0.0040in, Material: Siltek-Treated, Includes fitting and orifice

Replacement Fitting for Grab Sampling Kit, Orifice Size: 0.0055in, Material: Siltek-Treated, Includes fitting and orifice

Replacement Fitting for Grab Sampling Kit, Orifice Size: 0.0080in, Material: Siltek-Treated, Includes fitting and orifice

Replacement Fitting for Grab Sampling Kit, Orifice Size: 0.0090in, Material: Siltek-Treated, Includes fitting and orifice

Replacement Fitting for Grab Sampling Kit, Orifice Size: 0.0130in, Material: Siltek-Treated, Includes fitting and orifice

Brass Cap 1/4in and PTFE Ferrule for Thermal Desorption Unit Tubes, Benefits and Uses: Long-term storage of blank/sampled tube

Deluxe Canister Carrying Case, Heavy-duty, all-aluminum design fits two 6 L SilcoCan or TO-Can canisters tightly without foam, Weight: 9 lb, Inside dimensions: length 18in, width 9 1/8in, height 12 1/2in,No organic contaminants from foam or plastics

Thermal Desorption Unit (TDU) Tube. Thermal Desorption Unit (TDU) Tube, Sorbent: Graphitized Carbon (20/40 mesh), Type: Unconditioned, Material: Glass, Use corrosion-resistant glass tubes for excellent inertness; allow monitoring of sorbent bed condition, Individually etched

Stainless Steel Union 1/4in and PTFE Ferrules for Thermal Desorption Unit Tube, Benefits and Uses: Use for connecting tubes in series.

AuraPersonal Air Sampler Kit. Aura8 Personal Air Sampler Kit, Material: Siltek-Treated, Includes: 400 cc miniature canister with 1/4in quick-connect stem, quick-connect body, holster and belt, Of disposable 8-hour sampler lines, tubing cutter, & lapel clip, features robust sampler, Green technology

Soil Gas Sampler Replacement Tee 30 mL/min. Soil Gas Sampler Replacement Tee with Orifice, Flow Capacity: 30 mL/minute for 3hour, Orifice Size: 0.0025in, Material: Stainless Steel

Miniature Canister 400cc. Miniature Canister, Modification:without Valve, Material:Electropolished Stainless Steel,Volume:400 cc,Ideal for indoor air, personal, emergency response, or soil gas sampling, Dimensions: 7 x 13.6 cm

Canister Air Sampling Timer, Program up to 12 timed events, with manual and automated operation, for either grab/time-integrated sampling, with Long battery life, recharges using USB port on any PC, stainless steel sample flow path ensures inertness, improving accuracy.

Miniature Air Sampling Kit 0.5-2 mL/min. Miniature Air Sampling Kit, Flow Capacity: 0.5-2 mL/min, Orifice Size: 0.0008in, Material: SS, Convenient smaller size connects easily to miniature canisters, Includes: flow controller, critical orifice, 2 um frit filter, vacuum gauge, and sample inlet

Miniature Air Sampling Kit 4 - 8 mL/min. Miniature Air Sampling Kit, Flow Capacity: 4 - 8 mL/min, Orifice Size: 0.0016in, Material: SS, Convenient smaller size connects easily to miniature canisters, Includes: flow controller, critical orifice, 2 um frit filter, vacuum gauge, and sample inlet

RAVE Diaphragm Rebuild Kit, Material:Stainless Steel, Includes:diaphragms (3), Features: Durable design to exceed 15,000 cycles, helium leak-tested to 1x10 raised to -6 mL/sec, easily finger-turn to achieve full valve closure, W-type valve seats are work-hardened

Ashcroft Test Gauge 3in. Ashcroft Test Gauge, Type: Digital, Diameter: 3 in, Fittings: 1/4 in NPT, Accurate measurement of vacuum to -30in Hg and pressure to 60 psi, Accuracy to +/- 0.25%, operates on two AAA batteries, for verifying the vacuum/pressure in canisters before and after sampling

Gauge Connector to Canister Valve. Ashcroft Gauge Connector to Canister Valve, stainless steel, connects 1/4in male NPT to 1/4in male compression fitting

Cleaned Polyurethane Foam (PUF) Cartridge. Cleaned Polyurethane Foam, Large (PUF)/XAD Cartridge, Use for collection of semivolatiles (pesticides, PCBs, PAHs), Suitable for ambient, indoor, and industrial hygiene applications, PUF/10 g XAD-2/50 mm PUF, 65 mm OD x 125 mm length, 25 mm

Soil Gas Sampler Replacement Tee with Orifice, Flow Capacity: 80 mL/min, Orifice Size: 0.0040in, Material: Stainless Steel

Soil Gas Sampler Replacement Tee with Orifice, Flow Capacity: 19 mL/min, Orifice Size: 0.0020in, Material: Stainless Steel

Aura Personal Air Sampler (Disposable 8-Hour Sampler Line).

Cartridge 7.6 cm. Cartridge, Cleaned Polyurethane Foam (PUF), plug, Length: 7.6 cm, Diameter: 6 cm, for collection of semivolatiles (pesticides, PCBs, PAHs), with large high volume (220-280 L/min), small low-volume (1-5 L/min) PUF, Suitable for ambient, indoor, and industrial hygiene applications

Thermal Desorption Unit Tube, Empty tubes for direct desorption of VOCs from liquids, solids, or pastes, Material: Stainless Steel, front sorbent-retaining gauze, rear gauze, and gauze retaining spring, Empty tubes for direct desorption of VOCs from liquids

Grab Passive Air Sampling Kit. Grad Passive Air Sampling Kit, Flow Capacity: 20 mL/min, Orifice Size: 0.0020in, Material: Siltek-Treated, Use with 1, 3, 6 L canisters, Connect 1/4in compression fitting directly to canister valve inlet, Replaceable frit protects orifice and valve from particulates

Dual Canister Sampling Manifold, Precise dimension: (9.5in w x 3.5in h) provide accurate splitting of sample between two canisters, Material: Siltek-Treated, Uses 1/4in compression connection, with Thick-walled stainless steel tubing rugged enough for field use

Lapel Clip, Metal with Card Clamp for Aura Personal Air Samplers.

MTS-32 TD Multiple Tube Sequential Sampler, Allows sampling up to 32 thermal desorption tubes, diffusion-locking technology prevents sample loss, portable, Quality construction made of low-outgassing materials, include built-in fan, 110-240V power/battery

TO-Can Air Sampling Canister 15L. TO-Can Air Sampling Canister, with Swagelok SS4H Bellows Valve, High quality, Bellows-design valve, Proprietary electropolished surface that maintains compound stability, Volume: 15L

Replacement Frit for Grab Sampling Kit, Material: Stainless Steel, 10 um.

Dual Canister Sampling Manifold, Precise dimension: (9.5in w x 3.5in h) provide accurate splitting of sample between two canisters, Material: Stainless Steel, Uses 1/4in compression connection, with Thick-walled stainless steel tubing rugged enough for field use

TO-Can Air Sampling Canister 1L. TO-Can Air Sampling Canister, with Swagelok SS4H Bellows Valve, High quality, Bellows-design valve, Proprietary electropolished surface that maintains compound stability, Volume: 1 L

TO-Can Air Sampling Canister 6L. TO-Can Air Sampling Canister, with Swagelok SS4H Bellows Valve, High quality, Bellows-design valve, Proprietary electropolished surface that maintains compound stability, Volume: 6L

Cleaned Polyurethane Foam (PUF) Cartridge. Cleaned Polyurethane Foam, Large (PUF) Cartridge, Use for collection of semivolatiles (pesticides, PCBs, PAHs), Suitable for ambient, indoor, and industrial hygiene applications, 65 mm OD x 125 mm length, 75 mm

Thermal Desorption Unit (TDU) Tube. Thermal Desorption Unit (TDU) Tube, Sorbent: Carbopack C (60/80 mesh)/Carbopack B (60/80 mesh)/Carbosieve SIII (60/80 mesh), Material: Stainless Steel, Individually etched with unique serial number for convenient sample identification

Passive Air Sampling Kit 80-340 mL/min. Passive Air Sampling Kit, Integrated, Flow Capacity: 80-340 mL/min, Orifice Size: 0.0090in, Material: Siltek-Treated, Superior Performance, Excellent for sampling times from 0.5 hour to 125 hours, Provide accurate integrated sampling without a sampling pump

Miniature Air Sampling Kit 0.5-2 mL/min. Miniature Air Sampling Kit, Flow Capacity: 0.5-2 mL/min, Orifice Size: 0.0008in, Material: Siltek-Treated, Convenient smaller size connects to miniature canisters, Includes: flow controller, critical orifice, 2 um frit filter, vacuum gauge, and sample inlet

Miniature Air Sampling Kit 4 - 8 mL/min. Miniature Air Sampling Kit, Flow Capacity: 4 - 8 mL/min, Orifice Size: 0.0016in, Material: Siltek-Treated, Convenient smaller size connects to miniature canisters, Includes: flow controller, critical orifice, 2 um frit filter, vacuum gauge, and sample inlet

Miniature Air Sampling Kit 8 - 15 mL/min. Miniature Air Sampling Kit, Flow Capacity: 8 - 15 mL/min, Orifice Size: 0.0020in, Material: Siltek-Treated, Convenient smaller size connects to miniature canisters, Includes: flow controller, critical orifice, 2 um frit filter, vacuum gauge, and sample inlet

Multi-Layer Foil Gas Sampling Bag, Modification:Polypropylene Combo Valve and Septum, Volume: 40 L, Size: 24in x 24.5in, Chemically inert with light and moisture protection, Not recommended for low ppm VOCs due to background levels, Protective 5-layer barrier

Multi-Layer Foil Gas Sampling Bag, Modification:Polypropylene Combo Valve and Septum, Volume: 12 L, Size: 13in x 24in, Chemically inert with light and moisture protection, Not recommended for low ppm VOCs due to background levels, Protective 5-layer barrier

Multi-Layer Foil Gas Sampling Bag, Modification: Polypropylene Combo Valve and Septum, Volume: 1 L, Size: 12in x 22in, Chemically inert with light and moisture protection, Continous sampling temperature up to 190 deg F (88 deg C), Composition: 5-layer

Veriflo Flow Controllers 80-340 mL/min. Veriflo Flow Controllers, Flow Capacity: 80-340 mL/min, Orifice Size:0.0090in, Material: Siltek-Treated, critical orifice in a Veriflo flow controller is interchangeable

Thermal Desorption Unit (TDU) Tube. Thermal Desorption Unit (TDU) Tube, Sorbent: Tenax GR (35/60 mesh)/Carbopack B (60/80 mesh), Type: Conditioned & Capped, Material: Stainless Steel, Individually etched with unique serial number for convenient sample identification

Replacement Quick-Connect Body with 1/4in Adaptor for Aura Personal Air Sampler, 1/8inch.

Soil Gas Sampler Replacement Tee with Orifice, Flow Capacity: 6 mL/min, Orifice Size: 0.0014in, Material: Siltek-Treated

Universal Battery Charger for Vacuum Bag Sampler Model 1062 (115/230 VAC).

Grab Passive Air Sampling Kit. Grad Passive Air Sampling Kit, Flow Capacity: 150 mL/min, Orifice Size: 0.0055in, Material: Stainless Steel, Use with 1, 3, 6 L canisters, Connect 1/4in compression fitting directly to canister valve inlet, Replaceable frit protects orifice and valve from particulates

Grab Passive Air Sampling Kit. Grad Passive Air Sampling Kit, Flow Capacity: 300 mL/min, Orifice Size: 0.0080in, Material: Stainless Steel, Use with 1, 3, 6 L canisters, Connect 1/4in compression fitting directly to canister valve inlet, Replaceable frit protects orifice and valve from particulates

Grab Passive Air Sampling Kit. Grad Passive Air Sampling Kit, Flow Capacity: 390 mL/min, Orifice Size: 0.0090in, Material: Stainless Steel, Use with 1, 3, 6 L canisters, Connect 1/4in compression fitting directly to canister valve inlet, Replaceable frit protects orifice and valve from particulates

Grab Passive Air Sampling Kit. Grad Passive Air Sampling Kit, Flow Capacity: 1000 mL/min, Orifice Size: 0.0130in, Material: Stainless Steel, For 1, 3, 6 L canisters, Connect 1/4in compression fitting directly to canister valve inlet, Replaceable frit protects orifice and valve from particulates

Thermal Desorption Unit (TDU) Tube. Thermal Desorption Unit (TDU) Tube, Sorbent: Tenax GR (35/60 mesh)/Carbopack B (60/80 mesh), Type: Conditioned & Capped, Material: Stainless Steel, Individually etched with unique serial number for convenient sample identification

Miniature Air Sampling Kit 2 - 4 mL/min. Miniature Air Sampling Kit, Flow Capacity: 2 - 4 mL/min, Orifice Size: 0.0012in, Material: SS, Convenient smaller size connects easily to miniature canisters, Includes: flow controller, critical orifice, 2 um frit filter, vacuum gauge, and sample inlet

Sampling Belt, Mini-Can Accessories, Adjustable up to 50in, Straps slide anywhere on belt, Versatile design, perfect for personal wear or hang for area sampling, Two reclosable hook-and-loop straps securely hold mini-can or other sampling device

Air Liquide Single Stage VOC Regulator, Fittings: CGA-180 (0-30 psig), Material: Stainless Steel, Features: Single-stage, Two pressure gauges, Stainless steel diaphragm and Kel-F seat, Accurate pressure control even at low flow rates, Individually tested

Replacement Frit for Grab Sampling Kit, Material: Siltek-Treated, 10 um.

ALTEF Gas Sampling Bag, Modification: Polypropylene Combo Valve and Septum, Volume: 5 L, Size: 12in x 12in, Very low VOC and sulfur background, Durable PVDF film is resistant to abrasion and chemicals, Contain no additives, fillers, or pigment

Vacuum Gauge 1 1/2in. Vacuum Gauge, Diameter:1 1/2in, Fittings:1/8in NPT, with 316 stainless steel wetted surfaces, -30in Hg to 0in Hg, Recommended for use with passive sampling kits, rear mount

Soil Gas Sampler Replacement Tee with Orifice, Flow Capacity: 210 mL/min, Orifice Size: 0.0065in, Material: Stainless Steel

Category
  • Prev
  • 8
  • 9
  • 10
  • 11
  • 12
  • Next

We search our sources worldwide for the best values in medical products and select the best values. We offer them here so you can shop in confidence.

Useful Links

  • Support

Help

  • Home
  • About Us
  • Contact Us

Policy

  • Privacy policy
  • Terms and Conditions
  • Return Policy
  • Refund Policy

Copyright® 2016 - 2025 RELIANCE INC | All rights reserved.

Icon