logo
  • About Us
    • Retail Customer Login
    • Business User Login
    • Retail Customer Registration
    • Business User Registration
  • 0
  • Shop Products
    • Ambulatory Equipment
    • Apparel
    • Appliances (Durable Goods)
    • Body Pressure Relief and Positioning
    • Clinical Laboratory
    • Diagnostic Instruments and Supplies
    • Drainage and Suction
    • Furnishings
    • Gloves
    • Housekeeping
    • Implants
    • Incontinence
    • Indicators and Signage
    • Instruments
    • IV Therapy
    • Needles and Syringes
    • Nurse's Station and Office Supplies
    • Nutritionals and Feeding Supplies
    • Orthopedic
    • Ostomy
    • other
    • Personal Hygiene
    • Pharmaceuticals
    • Physical Therapy
    • Respiratory
    • Services
    • Sterilization
    • Textiles
    • Training and Education
    • Urological
    • Utensils
    • Ventilators
    • Wound Care
    • Wound Closure
logo
  • 0
  • Retail Customer Login
  • Business User Login
  • Retail Customer Registration
  • Business User Registration
Shop Products
  • Ambulatory Equipment
  • Apparel
  • Appliances (Durable Goods)
  • Body Pressure Relief and Positioning
  • Clinical Laboratory
  • Diagnostic Instruments and Supplies
  • Drainage and Suction
  • Furnishings
  • Gloves
  • Housekeeping
  • Implants
  • Incontinence
  • Indicators and Signage
  • Instruments
  • IV Therapy
  • Needles and Syringes
  • Nurse's Station and Office Supplies
  • Nutritionals and Feeding Supplies
  • Orthopedic
  • Ostomy
  • other
  • Personal Hygiene
  • Pharmaceuticals
  • Physical Therapy
  • Respiratory
  • Services
  • Sterilization
  • Textiles
  • Training and Education
  • Urological
  • Utensils
  • Ventilators
  • Wound Care
  • Wound Closure
$

Sponge Tip. For the Adjustable Vertical Electrophoresis Systems 27372-000, -002, and -026, the Aluminum Backed Sequencers 27372-796 and -788, and the NUGENEration Sequencing Buffer Backed Systems 27372-694, -732, and -768. For use with offset glass plates.

Replacement Gasket. For the NUGENEration Buffer Backed Sequencer 27372-694.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 20Wx20Lcm. Sharktooth microtiter format. Number of teeth: 36 (2X). Teeth are spaced to allow for microtitration of every other well. Tooth thickness: 0.4mm. Well volume: 10uL.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 20Wx20Lcm. Sharktooth microtiter format. Number of teeth: 55 (3X). Teeth are spaced to allow for microtitration of every third well. Tooth thickness: 0.4mm. Well volume: 5.5uL.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 20Wx20Lcm. Sharktooth microtiter format. Number of teeth: 73. Teeth are spaced to allow for microtitration of every fourth well. Tooth thickness: 0.2mm. Well volume: 2.0uL.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 20Wx20Lcm. Sharktooth microtiter format. Number of teeth: 73. Teeth are spaced to allow for microtitration of every fourth well. Tooth thickness: 0.4mm. Well volume: 3.7uL.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 20Wx20Lcm. Sharktooth type. Number of teeth: 39. Tooth thickness: 0.2mm. Well volume: 5uL.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 20Wx20Lcm. Sharktooth type. Number of teeth: 39. Tooth thickness: 0.4mm. Well volume: 9uL.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 20Wx20Lcm. Well/sequencing type. Number of teeth: 20. Tooth width: 6.8mm. Tooth thickness: 0.4mm. Well volume: 15uL.

Blank Glass Plate. For Owl Separation Systems Adjustable Vertical Electrophoresis Systems, Aluminum-Backed Sequencers, and Otter Gel Casting Systems with 20cm wide gel size. Dimensions: 20Wx45Lcmx4.8mm thick.

Notched Glass Plate. For Owl Separation Systems Adjustable Vertical Electrophoresis Systems, Aluminum-Backed Sequencers, and Otter Gel Casting Systems with 20cm wide gel size. Dimensions: 20Wx45Lcmx4.8mm thick.

Side Clamp. For the NUGENEration Buffer Backed Sequencers 27372-694 and -732. Provides uniform pressure across the gel.

Replacement Gasket. For the NUGENEration Buffer Backed Sequencer 27372-732.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 35Wx20Lcm. Sharktooth microtiter format. Number of teeth: 110. Teeth are spaced to allow for microtitration of every third well. Tooth thickness: 0.4mm. Well volume: 5.5uL.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 35Wx20Lcm. Sharktooth microtiter format. Number of teeth: 146. Teeth are spaced to allow for microtitration of every fourth well. Tooth thickness: 0.2mm. Well volume: 2.0uL.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 35Wx20Lcm. Sharktooth microtiter format. Number of teeth: 146. Teeth are spaced to allow for microtitration of every fourth well. Tooth thickness: 0.4mm. Well volume: 3.7uL.

Spacer. For Owl Separation Systems Aluminum Backed Sequencers 27372-796 and -788. Wedge type. Includes two side spacers only.

Spacer. For owl separation systems vertical electrophoresis systems with gel sizes 20wx20lcm and 35wx20lcm. width: 1.0cm. thickness: 0.4mm. plate length: 45cm. for sequencing gels only.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 35Wx20Lcm. Sharktooth type. Number of teeth: 78. Tooth thickness: 0.2mm. Well volume: 5uL.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 35Wx20Lcm. Sharktooth type. Number of teeth: 78. Tooth thickness: 0.4mm. Well volume: 9uL.

Comb. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 35Wx20Lcm. Well/sequencing type. Number of teeth: 40. Tooth width: 6.8mm. Tooth thickness: 0.4mm. Well volume: 15uL.

Offset Glass Plate. For Owl Separation Systems Adjustable Vertical Electrophoresis Systems, Aluminum-Backed Sequencers, and Otter Gel Casting Systems with 35cm wide gel size. Dimensions: 35Wx43Lcmx4.8mm thick.

Blank Glass Plate. For Owl Separation Systems Adjustable Vertical Electrophoresis Systems, Aluminum-Backed Sequencers, and Otter Gel Casting Systems with 35cm wide gel size. Dimensions: 35Wx45Lcmx4.8mm thick.

Notched Glass Plate. For Owl Separation Systems Adjustable Vertical Electrophoresis Systems, Aluminum-Backed Sequencers, and Otter Gel Casting Systems with 35cm wide gel size. Dimensions: 35Wx45Lcmx4.8mm thick.

Side Clamp. For the NUGENEration Buffer Backed Sequencer 27372-768. Provides uniform pressure across the gel.

Spacer. For Owl Separation Systems Vertical Electrophoresis Systems with gel size 35Wx20Lcm. Width: 1.0cm. Thickness: 0.4mm. Plate length: 65cm.

Aluminum Backed Sequencer. For uniform heat distribution and flat, even banding. Floating, anodized aluminum heat sink reduces glass breakage. Gel size: 45Lx35Wcm. Buffer volume: 800mL. Dimensions: 44Wx23Dx50Hcm. Includes two 78-tooth sharktooth combs and one 40-well comb, both 0.4mm thick.

Replacement Side Clamp. For the Aluminum Backed Sequencers, 27372-796 and -788. Mount the sliding clamp on the unit for easy set-up.

Buffer Drain Bottle. For the Aluminum Backed Sequencer, 27372-788. For the upper buffer chamber.

Replacement Gasket. For the Aluminum Backed Sequencer, 27372-788.

Aluminum Backed Sequencer. For uniform heat distribution and flat, even banding. Floating, anodized aluminum heat sink reduces glass breakage. Gel size: 45Lx20Wcm. Buffer volume: 450mL. Dimensions: 27Wx23Dx50Hcm. Includes two 39-tooth sharktooth combs and one 20-well comb, both 0.4mm thick.

Adhesive Temperature Indicator. For the Aluminum Backed Sequencers 27372-796 and -788 and the NUGENEration Sequencing Buffer Backed Systems 27372-694, -732, and -768.

Otter Sequencing Gel Caster. Gel size: 20-42Wx65.5Lcm. Dimensions, fully closed: 102Lx21.6Wx12.2Hcm. For casting bubble-free sequencing gels in under three minutes. Caster distributes the gel by capillary action and works by surface tension to eliminate leaks. Includes caster and 12 binder clamps.

Replacement Gasket. For the Aluminum Backed Sequencer, 27372-796. Set of two.

JVD-80 0.4mm 6-Well Comb.

JVD-80 0.4mm 27-Well Comb.

JVD-80 0.4mm 26-Well Comb.

JVD-80 0.4mm 36-Well Comb.

STS 45i DNA Sequencing Unit. Slant-back design. Gel size: 43Lx36Wcm. Plate Sizes: 45Lx37.5Wcm, 43Lx37.5Wcm. Capacity of up to 96 samples. Buffer Tank Capacity: 530mL (upper and lower). Coated aluminum thermoplate. Platinum electrodes. Standard and sharktooth combs. Standard spacers.

Gasket. For the STS 45i DNA Sequencing Unit, IB80000.

Spacer Tab Set. Includes four tabs. For the STS 45i DNA Sequencing Unit, IB80000.

Tape Sequencing. For use with STS-45i unit

Category

We search our sources worldwide for the best values in medical products and select the best values. We offer them here so you can shop in confidence.

Useful Links

  • Support

Help

  • Home
  • About Us
  • Contact Us

Policy

  • Privacy policy
  • Terms and Conditions
  • Return Policy
  • Refund Policy

Copyright® 2016 - 2025 RELIANCE INC | All rights reserved.

Icon